Peter Huber Kältemaschinenbau Petite Fleur-eo Dynamisches
Peter Huber Kältemaschinenbau Petite Fleur-eo Dynamisches — Temperature control units with Noise level 58 dB.
The Petite Fleur-eo Dynamisches is a variable-speed pressure-pump temperature control unit for external open operation, with no expansion tank. It covers -40 to 200 °C with 1.6–2 kW heating and 0.04 kW cooling at -40 °C, distinguishing it from larger Grande Fleur siblings. It serves low-heat-load processes requiring precise Pilot ONE control.
Peter Huber Kältemaschinenbau Unistate Bis 45C Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Power supply | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Petite Fleur-eo Dynamisches Current | 58 | 0, 01 K | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | Pressure pump, variable | -40–200 |
| Grande Fleur Dynamisches | — | — | — | — | — | — |
| Grande Fleur w Dynamisches | — | 0, 01 | 208-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | -40–200 |
| Grande Fleur w-eo Dynamisches | — | — | — | — | — | — |
| Petite Fleur w Dynamisches | — | 0, 01 | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | Pressure pump, variable | -40–200 |
| Unistat 410w Dynamisches | 61 | 0, 01 K | 220-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | -45–250 |
| Unistat 425w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat 430w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P405w Dynamisches | — | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st | -45–250 |
| Unistat P425 Dynamisches | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P425w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P430 Dynamisches | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P430w Dynamisches | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
Full specifications
| Noise level | 58 dB(A) (sound pressure level) |
| Control output | POKO ONE (potential-free contact) |
| Filling volume | 2 l (min) |
| Maximum delivery flow rate | 25 l/min (pressure pump max; 0, 9 bar) |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | Yes |
| Pump type | Pressure pump, variable speed |
| External sensor connection | Pt100 |
| Temperature range | -40...200 °C |
| Alarm message mfr | optic, acoustic, relay |
| Dimensions (W x D x H) mfr | 260 x 450 x 504 mm |
| Heating capacity mfr | 1, 6 - 2 kW |
| Refrigeration machine mfr | air-cooled, natural refrigerant |
| Control input mfr | ECS ONE |
| Weight | 43 kg (net) |
| Power supply | 220-240V 1~/2~ 50/60Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Refrigerant | R-290 (A3, H220) (1st stage) |
| Maximum viscosity | 50 mm²/s (max permissible) |
| Refrigerant quantity 1st stage mfr | 0, 08 kg (1st stage) |
| Ambient temperature limit | 5...40 °C (permissible) |
| Protection rating | IP20 |
| Cooling capacity mfr | 0, 04 kW (at -40 °C) |
| Safety class | III / FL |
Description
Construction and positioning
- The Petite Fleur-eo Dynamisches is a compact (260 x 450 x 504 mm, 43 kg) unit built for external open operation only; it has no expansion tank, so the external application must accommodate fluid filling and temperature-dependent volume changes.
- It uses a variable-speed pressure pump with M16x1 male connections, delivering up to 25 l/min at 0.9 bar.
- Refrigeration is air-cooled with R-290 (A3, H220) natural refrigerant, 0.08 kg in the first stage.
- Within the Unistate Bis 45C series, it is the smallest sibling; the Grande Fleur variants offer larger capacities but are not described here.
Behavior under load and media
- Temperature range is -40 to 200 °C, with heating capacity 1.6–2 kW and cooling capacity 0.04 kW at -40 °C (with ethanol). The low-end cooling is suitable only for low heat loads.
- Cooling capacity is rated at 20 °C room temperature and may drop at higher ambient; permissible ambient is 5–40 °C.
- Thermal fluid viscosity must not exceed 50 mm²/s at the lowest working temperature; different fluid types must never be mixed, and the circuit must be rinsed when changing fluid type.
- Minimum filling volume is 2 l.
Installation, control and operation
- The Pilot ONE controller supports selectable internal/process temperature control mode and external Pt100 sensor connection; display resolution is 0.01 K.
- Interfaces include Ethernet, USB (Host and Device), and RS232; control output is POKO ONE potential-free contact, and control input is ECS ONE.
- Power supply is 220–240 V 1~/2~ 50/60 Hz with country-specific plug to be specified at order; voltage tolerance ±5% only with simultaneous frequency tolerance ±2%.
- Protection rating is IP20; EMC classification is Class A, Group 1 (industrial environments).
- The unit must not be installed in an ATEX zone without an Ex px cabinet; a drip tray must be installed below the unit.
- For natural refrigerant, if charge exceeds 8 g per m³ of room air, a calibrated gas warning sensor is mandatory; units with more than 1 kg refrigerant must not be installed below ground level (this unit has 0.08 kg, so this restriction does not apply).
- Circulation flow must connect to the lower port of the application and return to the higher port to vent air bubbles.
- Power cable must not exceed 3 m for safe disconnection.
Integration & Operating Notes
The unit must not be installed or started in a hazardous area unless an Ex px cabinet is used; verify the site classification before installation to avoid a safety violation.
Since the unit has no expansion tank, the external application must accommodate fluid expansion and ensure a minimum filling volume of 2 l to avoid cavitation and poor temperature control.
Do not use a power cable longer than 3 m so the unit can be disconnected from the mains at any time; plan the power outlet location accordingly.
The Pilot ONE controller allows choosing between internal and process temperature control; for process control, connect an external Pt100 sensor and configure the setpoint accordingly.
The air filter mat behind the air inlet must be checked and replaced regularly to prevent reduced airflow, which can cause overheating and reduced cooling performance.
Selection & Integration Q&A
Choose this model for low heat loads (0.04 kW cooling at -40 °C) and space-constrained installations; Grande Fleur siblings offer higher capacities but are larger. This unit is for external open operation only, without expansion tank.
Use M16x1 male fittings; ensure the external loop provides at least 2 l fill volume and accommodates expansion. Connect circulation flow to the lower port and return to the higher port to vent air. Check pressure drop against 0.9 bar max.
The air filter mat must be checked and replaced regularly. A country-specific plug must be specified at order. A drip tray and, if refrigerant charge exceeds 8 g/m³ room air, a gas warning sensor are required. Thermal fluid is not included.