Peter Huber Kältemaschinenbau Unistat P405w Dynamisches
Peter Huber Kältemaschinenbau Unistat P405w Dynamisches — Temperature control units.
The Unistat P405w Dynamisches is a water-cooled, high-pressure-drop circulating thermostat with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -45 to 250 °C with 3 kW heating. Its 'P' designation targets applications with high pressure drop, distinguishing it from the Grande Fleur siblings. It serves closed-loop temperature control of externally closed processes requiring elevated pump head.
Peter Huber Kältemaschinenbau Unistate Bis 45C Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Power supply | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat P405w Dynamisches Current | — | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st | -45–250 |
| Grande Fleur Dynamisches | — | — | — | — | — | — |
| Grande Fleur w Dynamisches | — | 0, 01 | 208-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | -40–200 |
| Grande Fleur w-eo Dynamisches | — | — | — | — | — | — |
| Petite Fleur-eo Dynamisches | 58 | 0, 01 K | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | Pressure pump, variable | -40–200 |
| Petite Fleur w Dynamisches | — | 0, 01 | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | Pressure pump, variable | -40–200 |
| Unistat 410w Dynamisches | 61 | 0, 01 K | 220-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | -45–250 |
| Unistat 425w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat 430w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P425 Dynamisches | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P425w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P430 Dynamisches | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P430w Dynamisches | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
Full specifications
| Control output | POKO ONE |
| Heating capacity | 3 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -45...250 °C |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Water-cooled refrigeration machine using natural refrigerant R-1270 (A3, H220), requiring on-site cooling water supply and return.
- Magnetically coupled stainless-steel pump with adjustable speed and M30x1.5 male connections (bore shape Y, 60°, DIN 3863).
- The 'P' suffix denotes a modification for applications with high pressure drop; the 'w' suffix denotes water cooling. Sibling Grande Fleur variants differ in configuration and are not interchangeable for high-pressure-drop duty.
- No plate heat exchanger on this model family (Unistat 405(w) listed among units without one), so the warning against very rapid recurring temperature changes does not apply in the same way.
- Thermally passive expansion tank prevents HTF vapour and moisture absorption; for externally open baths it is blocked off so the thermostat is atmospherically sealed.
Behavior under load and media
- Temperature range -45 to 250 °C; heating capacity 3 kW.
- Cooling capacity with ethanol falls steeply at low temperature: 1.3 kW at 0 °C down to 0.1 kW at -40 °C — low-temperature duty must be sized against this curve, not the nominal figure.
- Maximum permissible kinematic viscosity of the heat transfer fluid is 50 mm²/s; FL-rated fluids require a fire point ≥ 65 °C, and ethanol use is permitted only under supervision.
- Process Safety mode releases maximum cooling at the overtemperature trigger instead of switching off all poles; it requires the compressor set to Permanently ON.
Installation, control and operation
- Pilot ONE controller with POKO ONE control output, 0.01 K display resolution, Ethernet, USB (host and device) and RS232 interfaces; external Pt100 sensor input.
- Electrical supply 460 V 3~ 60 Hz with ±5 % voltage and simultaneous ±2 % frequency tolerance; external branch circuit protection per UL 489 required; three-phase units under 63 A are supplied with cable but without plug.
- Cooling water: G1/2 male connections, differential pressure min. 1 bar, max. 6 bar; intake temperature 5–20 °C, with insulation required below the condensation point.
- IP20, ambient 5–40 °C; must not be installed in an ATEX zone; not permissible for medical-device or direct-foodstuff use.
Integration & Operating Notes
The refrigeration machine is water-cooled, so the installation site must provide cooling water supply and return at G1/2 male connections. Differential pressure must be at least 1 bar and must not exceed 6 bar; intake temperature must lie between 5 and 20 °C, and pipes must be insulated below the condensation point.
Supply is 460 V 3~ 60 Hz with ±5 % voltage and simultaneous ±2 % frequency tolerance. External branch circuit protection according to UL 489 is mandatory. Because current is below 63 A, the unit arrives with cable but without plug, so the installer must provide a suitable plug or hardwired connection; connection must be made by an electrician.
Only transport the unit upright and emptied; horizontal transport damages the compressor. Casters are not for transport and carry only 25 % of total mass symmetrically. After moving between cold and warm environments, allow about 2 hours acclimation before switching on to avoid condensation-induced electrical faults.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage to the application. For externally open bath applications the vessel must be locked to prevent fluid loss. The thermally passive tank otherwise prevents HTF vapour and moisture absorption.
In Process Safety mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles. This mode requires the compressor to be set to Permanently ON; otherwise the protective cooling response is not available. Configure the power-failure behavior (Off/Standby vs ON) according to whether unattended restart is acceptable.
Close the cooling water supply even for short downtimes such as overnight to prevent water damage and unnecessary load on the circuit. Periodically check hoses and hose connections for leaks and quality and replace as required. Refrigerant-circuit work must be performed by approved refrigeration/air-conditioning contractors.
Selection & Integration Q&A
Choose the P405w when the application has high pressure drop (the 'P' designation) and requires water cooling ('w'). Grande Fleur variants are different configurations of the series and should be selected when their cooling/connection configuration matches the duty; the P405w is the high-pressure-drop, water-cooled modification.
Provide cooling water supply/return at G1/2 male with 1–6 bar differential pressure and 5–20 °C intake, plus a 460 V 3~ 60 Hz supply with UL 489 branch protection and a site-supplied plug or hardwired connection, since the unit ships with cable but no plug.
Install indoors at 5–40 °C ambient, IP20, never in an ATEX zone. Transport upright and empty, acclimate about 2 hours after temperature change, and set the expansion vessel per open/closed application. Not permitted for medical-device or direct-foodstuff use.
The base unit excludes the site plug, cooling water hoses and insulation, drip tray, and heat transfer fluid. Plan periodic hose/connection inspection and replacement, cooling water shutoff for overnight downtime, and refrigerant-circuit service only by approved contractors.