Peter Huber Kältemaschinenbau Minichiller 600-H OLÉ Kompakter
Peter Huber Kältemaschinenbau Minichiller 600-H OLÉ Kompakter — Recirculating chillers with Noise level 56 dB.
The Minichiller 600-H OLÉ Kompakter is a compact recirculating chiller with a pressure-suction pump and OLÉ controller, rated for -20 to 100 °C. It distinguishes itself within the Minichiller series by its 0.6 kW cooling capacity at 15 °C and R-290 refrigerant. It serves sub-ambient cooling and moderate heating duties in laboratory and industrial circuits.
Peter Huber Kältemaschinenbau Minichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Minichiller 600-H OLÉ Kompakter Current | 56 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | — | — |
| Minichiller 1200w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 280 OLÉ Kompakter | 53 | OLÉ | I / NFL | -5–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300 OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w-H OLÉ Kompakter | 51 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 600 Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 110-120V 1~ 60Hz |
| Minichiller 600 OLÉ Kompakter | 56 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 60Hz |
| Minichiller 600w OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
Full specifications
| Noise level | 56 dB(A) (sound pressure level) |
| Maximum delivery flow rate | 24 l/min (pressure pump max, 0, 7 bar) |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure- and suction pump |
| Temperature range | -20...100 °C |
| Weight | 36 kg (net) |
| Current consumption | 12 A (max) |
| Fuse rating | 16 A |
| Power supply | 208-240V 1~/2~ 50/60Hz |
| Controller | OLÉ |
| Display resolution | 0, 1 K |
| Digital interface | USB (Device), RS232 Interface |
| Temperature display | OLED Display |
| Ambient temperature limit | 5...40 °C (permissible) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and Series Positioning
The Minichiller 600-H OLÉ Kompakter is a compact, air-cooled recirculating chiller from the Minichiller series. It uses R-290 (A3, H220) refrigerant and is configured with a pressure-suction pump (M16x1 male connections) and the OLÉ controller with OLED display. Compared to sibling models such as the Minichiller 1000-H OLÉ Kompakter, which likely offers higher capacity, this 600-H variant is positioned for lower cooling loads. The 'H' suffix indicates heating capability, and the 'OLÉ' controller provides USB and RS232 interfaces. The unit is rated IP20 and safety class III/FL.
Performance and Behavior
Cooling capacity is strongly temperature-dependent: 0.6 kW at 15 °C, 0.5 kW at 0 °C, 0.35 kW at -10 °C, and 0.15 kW at -20 °C. This means low-temperature operation requires careful margin planning. The pump delivers up to 24 l/min at 0.7 bar, but a whisper mode reduces noise from 56 dB(A) to 51 dB(A) while cutting flow to 14 l/min and pressure to 0.2 bar. The pump speed is not adjustable, but the pressure-suction design supports both pressure and suction operation. The temperature range spans -20 to 100 °C, with a display resolution of 0.1 K.
Installation and Operation
Electrical supply is 208-240 V, 1~/2~, 50/60 Hz, with a maximum current of 12 A and a 16 A fuse. A country-specific plug must be specified at ordering. The unit must not be installed in an ATEX zone, and a drip tray for condensation water and thermal fluid is required below the unit. Electrical lines below the unit must be protected against liquid ingress. Ambient temperature must remain between 5 and 40 °C; cooling capacity may drop above 20 °C. The plastic pump is not resistant to acetone or polyglycols. For freeze protection, mix water with glysantine or ethylene glycol. Do not install valves or quick-release couplings in the feed/discharge lines.
Integration & Operating Notes
Operation within an ATEX zone can cause explosion. A drip tray for condensation water and thermal fluid must be installed below the unit to contain leaks. Electrical lines directly below must be protected against liquid ingress because condensation can form.
The unit draws up to 12 A and requires a 16 A fuse. Voltage tolerance is ±5% with simultaneous frequency tolerance of ±2%, and certain combinations are not allowed. A country-specific plug must be specified at ordering; otherwise, the unit may arrive without a local connection.
At -20 °C, cooling capacity is only 0.15 kW, compared to 0.6 kW at 15 °C. For low-temperature duty, ensure the load does not exceed available capacity. Ambient temperatures above 20 °C may further reduce capacity.
The standard plastic pump is not resistant to acetone or polyglycols. For these media, a different pump material is required. For freeze protection, mix water with glysantine or ethylene glycol; do not use neat water below 0 °C.
If salts such as chlorides or bromide are added to the water circuit, anti-corrosion agents are mandatory to prevent corrosion damage. Only drinking water or filtered river/sea water may be used as cooling water; sea water must not be used.
Whisper mode reduces sound pressure level to 51 dB(A) but also cuts pump delivery to 14 l/min and 0.2 bar. Ensure the reduced flow still meets the application's requirements before enabling this mode.
Selection & Integration Q&A
Choose the 600-H when your cooling load at the required temperature is below its capacity curve (e.g., 0.6 kW at 15 °C, 0.15 kW at -20 °C). The 1000-H offers higher capacity for larger loads. The 600-H is more compact and may suffice for lower-demand applications.
The pump uses M16x1 male connections, so mating hoses and fittings must match this thread. Do not install valves or quick-release couplings in the feed/discharge lines. Ensure the pump is compatible with your fluid; the plastic pump is not resistant to acetone or polyglycols.
Ambient temperature must be 5–40 °C; cooling capacity may drop above 20 °C. Install in a dry, protected location (IP20) away from water spray, not in an ATEX zone. A drip tray is required below the unit, and electrical lines below must be protected from liquid ingress.
A country-specific plug must be specified at ordering; otherwise, the unit may arrive without a local connection. For freeze protection, mix water with glysantine or ethylene glycol. If salts are added, anti-corrosion agents are mandatory. A drip tray must be installed on site.