Peter Huber Kältemaschinenbau Minichiller 800 OLÉ Kompakter
Peter Huber Kältemaschinenbau Minichiller 800 OLÉ Kompakter — Recirculating chillers.
The Minichiller 800 OLÉ Kompakter is an air-cooled recirculating chiller with a pressure/suction pump and OLÉ controller, rated -20...40 °C with an 80 °C return-line limit. Its 0.3 kW at -20 °C and 24 l/min at 0.7 bar distinguish it from larger 1000-series siblings. It serves closed-loop cooling of laboratory and pilot processes.
Peter Huber Kältemaschinenbau Minichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Minichiller 800 OLÉ Kompakter Current | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | — | — |
| Minichiller 1200w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 280 OLÉ Kompakter | 53 | OLÉ | I / NFL | -5–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300 OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w-H OLÉ Kompakter | 51 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 600-H OLÉ Kompakter | 56 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 600 Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 110-120V 1~ 60Hz |
| Minichiller 600 OLÉ Kompakter | 56 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 60Hz |
| Minichiller 600w OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
Full specifications
| Maximum delivery flow rate | 24 l/min (pressure pump; 0, 7 bar) |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure- and suction pump |
| Temperature range | -20...40 °C |
| Weight | 37 kg |
| Current consumption | 4 A (max) |
| Power supply | 208-240V 1~/2~ 50/60Hz |
| Controller | OLÉ |
| Display resolution | 0, 1 K |
| Digital interface | USB (Device), RS232 Interface |
| Temperature display | OLED Display |
| Ambient temperature limit | 5...40 °C |
| Maximum return flow temperature | 80 °C |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- Air-cooled, natural-draft refrigerant circuit using R-290 (A3, H220); no water cooling required.
- Pressure- and suction pump with fixed speed (not adjustable), M16x1 male connections; hose connector NW12 and sleeve nuts included.
- OLÉ controller with OLED display, 0.1 K resolution, USB (Device) and RS232 interfaces.
- IP20, safety class I / NFL, 37 kg.
- Within the Minichiller series, the 800 OLÉ Kompakter is the smaller-capacity OLÉ variant; the 1000-series siblings (1000, 1000-H, 1000w-H, with and without OLÉ) offer larger cooling capacity. This model is chosen when the load at the lowest setpoint is modest and space/weight matter.
Behavior under load and media
- Cooling capacity falls steeply with temperature: 0.3 kW at -20 °C. Size the chiller against the actual heat load at the lowest required setpoint, not at ambient.
- Operating range -20...40 °C, but the return line may reach 80 °C; this is a permissible limit, not an operating setpoint.
- Cooling capacity drops as ambient temperature rises; ambient must stay 5...40 °C.
- The plastic pump is not resistant to acetone or polyglycols; for sub-zero operation mix water with glysantine or ethylene glycol for freeze protection.
- Whisper mode reduces sound to 51 dB(A) but also reduces delivery to 14 l/min at 0.2 bar.
Installation, connection and control
- Supply 208-240 V 1~/2~ 50/60 Hz, max 4 A, min 10 A fuse; three-phase devices below 63 A come with cable but without plug.
- Voltage and frequency tolerances ±5 % and ±2 % may not be combined in the unfavorable direction.
- Do not install valves or quick-release couplings in feed/discharge lines to the application.
- A drip tray for condensation water and thermal fluid must be installed below the unit; electrical lines directly below must be protected against liquid ingress.
- Do not install in an ATEX zone; check refrigerant charge against room volume.
- Class A, Group 1 per EN55011; may need EMC measures in residential areas.
- Minimum filling capacity 2.8 l, expansion tank 2.2 l.
Integration & Operating Notes
Although the operating range is -20...40 °C, the return line tolerates up to 80 °C. Exceeding this limit risks damage to the evaporator and pump; ensure the application cannot return hotter fluid, especially during startup or batch dumps.
The wetted plastic pump is not resistant to acetone or polyglycols. Using these as heat transfer media will destroy the pump and contaminate the circuit; select an alternative fluid or a different pump material.
For operation below 0 °C, mix water with glysantine or ethylene glycol; pure water will freeze in the evaporator and damage the refrigeration circuit. Confirm the mixture concentration against the lowest setpoint.
A condensation water / thermal fluid drip tray must be installed below the chiller, and electrical lines directly below must be protected against liquid ingress, because condensation can form at the cooling water connections.
The unit must not be installed or started in an ATEX zone; operation there can cause explosion. Additionally, the R-290 (A3, H220) refrigerant charge must be checked against room volume to avoid exceeding the limit value per m³ of ambient air.
Supply tolerances are ±5 % voltage and ±2 % frequency, but a -5 % voltage combined with +2 % frequency is not allowed. Verify the site supply before connection to avoid motor and pump damage.
Three-phase devices with current consumption less than 63 A are supplied with cable but without a plug; the installer must provide the appropriate plug and connection. This model draws max 4 A at 208-240 V 1~/2~.
Do not install valves or quick-release couplings in the feed/discharge lines between the chiller and the application; closing them can overpressure the circuit and damage glass apparatus or the pump.
If salts such as chlorides or bromide are added to the water circuit, anti-corrosion agents are mandatory to prevent corrosion damage. Only drinking water or filtered river/sea water may be used; sea water must not be used.
The minimum filling capacity is 2.8 l and the expansion tank is 2.2 l; the external loop volume must be considered when filling to ensure enough heat transfer fluid and expansion volume for safe operation.
Selection & Integration Q&A
Choose the 800 OLÉ when the heat load at the lowest setpoint is modest (0.3 kW at -20 °C) and space/weight (37 kg) matter. The 1000-series siblings offer larger cooling capacity; select them when the load exceeds the 800's capacity at your setpoint.
The pump connections are M16x1 male; hose connector NW12 and sleeve nuts are included. Provide 208-240 V 1~/2~ 50/60 Hz supply with min 10 A fuse; three-phase below 63 A comes with cable but no plug. Do not add valves or quick-release couplings in the application lines.
Install between 5 and 40 °C ambient, not in an ATEX zone, with a drip tray below and protected cabling. Check R-290 charge against room volume. Air-cooled natural draft requires adequate airflow; capacity falls as ambient rises.
Use drinking or filtered river water only; sea water is prohibited. If salts are added, anti-corrosion agents are mandatory. For sub-zero operation, mix water with glysantine or ethylene glycol. Minimum filling 2.8 l; expansion tank 2.2 l. A plug for three-phase supply is not included.