No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1220 Infinity II Analytical-Scale LC Purification System

Agilent Technologies 1220 Infinity II Analytical-Scale LC Purification System — Liquid chromatography.

The 1220 Infinity II Analytical-Scale LC Purification System is a preparative HPLC configuration built around a 4.6 mm inner-diameter column and a typical flow rate of 1 mL/min, targeting microgram-level productivity. Within the InfinityLab purification series it is the analytical-scale entry point, distinct from the 1260 and 1290 preparative systems that handle larger column formats and higher mass loads.

Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection

Model Column inner diameter, mmTypical flow rate, mL/minPlate count, Nth/meterRetention time, minCarryover, %Sample capacity
1220 Infinity II Analytical-Scale LC Purification System Current 4.61————
1260 Analytical-Scale Purification System | Preparative HPLC 1...314060615.18——
1260 Infinity Bio-Inert Analytical-Scale LC Purification System 1...314060615.18——
1260 Infinity II Manual Preparative LC System 1...314060615.18——
1260 Infinity II Preparative LC System | UV based Prep HPLC 1...314060615.185132
1260 Prime Bio Analytical-Scale Purification System 4.61——9×10⁻⁴6144
1290 Analytical-Scale LC Purification 1...314060615.18——
1290 Infinity Autoscale Preparative system 1...314060615.18——
1290 Infinity III 4.61——9×10⁻⁴6144
1290 Infinity II Preparative LC System 1...314060615.18——
Automated LC/MSD purification| High-precision| Complex mixtures 1...314060615.18——
Flexible HPLC/UHPLC, Prime Analytical-Scale Purification System 1...314060615.18——
High-throughput Purification | Drug discovery | Biological 1...314060615.18——
Preparative LC/MSD System | Enhanced Purification & Efficiency 1...314060615.18——

Full specifications

Core Performance & Functional Specifications
Typical Flow Rate 1 mL/min
Productivity range mfr Micrograms Micrograms
Dimensions, Weight & Mechanical Design
Column Inner Diameter 4.6 mm

Description

Construction and series positioning

Behavior and media

Installation, control and operation

Integration & Operating Notes

Process Limits
Column format fixes the working scale at analytical dimensions

The system is specified with a 4.6 mm column inner diameter and a typical flow rate of 1 mL/min. Adjacent equipment — pumps, tubing, detector flow cells, and fraction collection — must be sized for this analytical-scale flow and column format; preparative-scale hardware from the 1260/1290 siblings is not interchangeable with this configuration.

Factory Specification Sheet
Process Limits
Recovery expectations are in the microgram range

The stated productivity range is micrograms. Purification targets requiring milligram or gram quantities fall outside this model's stated range and belong to the preparative siblings (1260 Infinity II Preparative LC System, 1260 Analytical-Scale Purification System) rather than this analytical-scale configuration.

Factory Specification Sheet
Electrical
Electrical and interface data not verified for this model

No voltage, current, power, or control-interface specifications were verified for this model. Before specifying power distribution or connecting a controller/data system, obtain the instrument-specific specification sheet; do not carry over electrical data from other InfinityLab purification systems.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the 1220 Infinity II Analytical-Scale LC Purification System instead of a 1260 preparative sibling?

Choose this model when the purification target is in the microgram range on a 4.6 mm column at about 1 mL/min. For milligram-to-gram recovery, larger columns, or bio-inert flow paths, the 1260 Analytical-Scale, 1260 Bio-Inert, or 1260 Infinity II Preparative systems are the appropriate series members.

What must adjacent system components be sized for when integrating this system?

Plumb and size the pump, tubing, detector cell, and collection hardware for a 4.6 mm column and a typical 1 mL/min flow. Verified facts give no pressure rating or solvent compatibility for this model, so confirm those from the instrument specification sheet before selecting mating parts.

What mounting, environment, or duty-cycle limits apply to this system?

No environment, mounting, or duty-cycle limits were verified for this model; the attached portfolio brochure contains no installation data. Obtain the instrument's own manual for bench space, ambient conditions, and continuous-operation limits before site planning.

What maintenance schedule and accessories are defined for this model in the verified facts?

No maintenance intervals, consumables list, or included accessories were verified. The brochure covers the portfolio and preparative columns/supplies generally, not this model's delivery scope; confirm columns, tubing kits, and service parts against the instrument's order documentation.

Dimensional Drawings & Technical Documentation

Technical documentation