Agilent Technologies 1290 Infinity Autoscale Preparative system
Agilent Technologies 1290 Infinity Autoscale Preparative system — Liquid chromatography.
The 1290 Infinity Autoscale Preparative system is a preparative HPLC configuration built around Load & Lock columns of 1–3 in id, operable in dynamic or static axial compression. It is distinguished within the preparative series by autoscale column handling and a typical analytical flow of 1 mL/min, serving method transfer and purification from microgram to preparative loads.
Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection
Full specifications
| Plate Count | 40606 Nth/meter |
| Retention Time | 15.18 min |
| Typical Flow Rate | 1 mL/min |
| Productivity range mfr | Micrograms Micrograms |
| Asymmetry mfr | 1.27 |
| Column Inner Diameter | 1...3 in |
Description
Construction and positioning
- The system is a preparative LC configuration within the Agilent InfinityLab purification portfolio, using Load & Lock columns with inside diameters from 1 to 3 in (27 to 75 mm).
- Columns are available in dynamic axial compression (DAC) and static axial compression (SAC) modes, with standard stainless steel water jackets.
- Sibling models in the series are analytical-scale purification systems (1220, 1260, 1260 Bio-Inert) and the 1260 Infinity II Manual Preparative LC System; this model is the autoscale preparative modification.
Behavior and performance
- Matched performance data include a plate count of 40606 N/m, retention time of 15.18 min, and typical flow rate of 1 mL/min; asymmetry is 1.27.
- Productivity range is stated in micrograms, consistent with analytical-to-preparative scale operation.
- No digitized curve points were supplied, so load-dependent behavior cannot be quantified from the available facts.
Installation and operation
- The attached brochure covers preparative modules including column organizer, column compartment, manual injector, open-bed sampler/collector, detectors, fraction collectors, and LC/MSD XT; the load-lock column document covers mobile packing stations for 1, 2 and 3 in id columns.
- No electrical, interface, or environmental specifications were verified for this model, so connection and control details are not asserted here.
Integration & Operating Notes
The Load & Lock column range is 1 to 3 in id (27 to 75 mm); packing stations are sized for 1, 2 and 3 in id columns, so column selection and station choice must match the id before installation.
Mobile packing stations for 1, 2 and 3 in id columns are described as separate equipment in the Load & Lock document; they are not part of the base LC system delivery and must be planned as an accessory.
Load & Lock columns support both dynamic axial compression and static axial compression; the compression mode determines how the column is packed and operated, so it must be fixed during method development rather than changed at run time.
Selection & Integration Q&A
Pick this model for autoscale preparative work with Load & Lock columns of 1–3 in id; choose the 1260 Infinity II Manual Preparative LC System when manual injection and operation are intended, and the 1220/1260 analytical-scale purification systems for analytical-scale rather than preparative loads.
Load & Lock columns in 1–3 in id (27–75 mm) with stainless steel water jackets, plus a mobile packing station sized for the chosen 1, 2 or 3 in id column; the packing station is separate equipment, not part of the base system.
Columns use standard stainless steel water jackets and are offered in DAC or SAC compression; the verified documents give no pressure, temperature or duty-cycle ratings, so operating limits must be obtained from the column datasheet before setting run conditions.
The mobile packing stations for 1, 2 and 3 in id columns are separate equipment. The brochure lists preparative modules (column organizer, column compartment, injector, sampler/collector, detectors, fraction collectors, LC/MSD XT) as portfolio items, so module selection must be specified separately.