Agilent Technologies 1260 Analytical-Scale Purification System | Preparative HPLC
Agilent Technologies 1260 Analytical-Scale Purification System | Preparative HPLC — Liquid chromatography.
The 1260 Analytical-Scale Purification System is a preparative HPLC configuration built around a 1260 Infinity II Analytical LC extended with the G1364F analytical-scale fraction collector. It targets gram-scale purification with 1–3 in id Load & Lock columns, 1 mL/min typical flow, and up to 10 mL/min for fraction collection. It bridges analytical LC and preparative LC for compound isolation at 50 mg purified target per run.
Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection
Full specifications
| Plate Count | 40606 Nth/meter |
| Retention Time | 15.18 min |
| Total Run Time | 13 minutes |
| Typical Flow Rate | 1 mL/min |
| Productivity range mfr | Micrograms Micrograms |
| Asymmetry mfr | 1.27 |
| Maximum flow rate for fraction collection mfr | 10 mL/min |
| Injection volume for quantitation mfr | 0.5 μL |
| Injection volume for purification mfr | 75...100 μL |
| Needle wash mfr | 10 s |
| Resolution (EP) — ZORBAX Eclipse Plus C18 mfr | 13.1 |
| Selectivity — ZORBAX Eclipse Plus C18 mfr | 1.71 |
| Resolution (EP) — InfinityLab Poroshell 120 mfr | 16.3 |
| Selectivity — InfinityLab Poroshell 120 mfr | 1.73 |
| Resolution (EP) — Pursuit XRs mfr | 13.8 |
| Selectivity — Pursuit XRs mfr | 1.60 |
| Maximum injection volume without significant coelution — Pursuit XRs mfr | 100 μL |
| Maximum injection volume without significant coelution — Pursuit XRs (repeated loading) mfr | 80 μL |
| Purity of collected fractions mfr | 99 |
| Recovery mfr | 96...97 |
| Recovery — Pursuit XRs (repeated loading) mfr | 97 |
| Maximum purified target compound mfr | 50 mg |
| Sample concentration — HBA mfr | 8 mg/mL |
| Sample concentration — target compound mfr | 40 mg/mL |
| Column Inner Diameter | 1...3 in |
| Peak width (10%) — ZORBAX Eclipse Plus C18 mfr | 0.085 |
| Peak width (10%) — InfinityLab Poroshell 120 mfr | 0.065 |
| Peak width (10%) — Pursuit XRs mfr | 0.085 |
Description
Construction and series positioning
- This modification is the analytical-scale purification member of the 1260 Infinity II LC line: an analytical LC (binary or quaternary gradient, autosampler, column compartment, detector) extended with the 1260 Infinity II Analytical-Scale Fraction Collector (G1364F).
- It sits between the 1220 Infinity II Analytical-Scale LC Purification System (lower-pressure, entry-level) and the 1260 Infinity II Preparative LC System (UV-based prep, larger columns and flows). The Bio-Inert variant is for metal-sensitive biomolecules; the Manual Preparative system is for open-bed, manual injection work.
- Columns are Agilent Load & Lock in 1, 2, and 3 in id (27–75 mm), available in dynamic axial compression (DAC) and static axial compression (SAC) modes with standard stainless steel water jackets.
Behavior under load and in different modes
- At 1 mL/min typical flow, plate count reaches 40,606 N/m with 15.18 min retention and 13 min total run time.
- Fraction collection is rated to 10 mL/min maximum; injection volume is 0.5 µL for quantitation and 75–100 µL for purification, with a 10 s needle wash.
- Column chemistry affects resolution and loading: InfinityLab Poroshell 120 gives the narrowest 10% peak width (0.065) and highest resolution (16.3), ZORBAX Eclipse Plus C18 gives 0.085 / 13.1, and Pursuit XRs gives 0.085 / 13.8 with selectivity 1.60.
- Pursuit XRs tolerates up to 100 µL injection without significant coelution (80 µL on repeated loading), with 97% recovery on repeated loading. Overall purity of collected fractions is 99% and recovery 96–97%.
- Maximum purified target compound is 50 mg; sample concentration is 8 mg/mL (HBA) and 40 mg/mL (target compound).
Installation, connection, and operation
- The system is assembled from InfinityLab LC Purification Solutions modules: column organizer, column compartment, manual injector, open-bed sampler/collector, detectors, fraction collectors, and optional LC/MSD XT.
- Load & Lock columns require a mobile packing station matched to the column id (1, 2, or 3 in); packing is done in DAC or SAC mode before installation.
- The technical overview describes the workflow as an analytical LC extended with the G1364F fraction collector, so the collector is an add-on to the base analytical LC rather than a standalone preparative skid.
Integration & Operating Notes
The analytical-scale fraction collector is rated for a maximum of 10 mL/min during collection. Exceeding this during a purification run risks fraction loss, carryover, or collector overflow; scale the gradient and column id so the collection step stays within this ceiling even though the analytical LC pump may support higher analytical flows.
Purification injections of 75–100 µL are intended for the Load & Lock column configuration; on Pursuit XRs the maximum without significant coelution is 100 µL, dropping to 80 µL on repeated loading. Quantitation injections are 0.5 µL. Exceeding the column-specific loading limit degrades resolution and purity of collected fractions.
The method includes a 10 s needle wash. Skipping or shortening it in method development risks carryover between the 75–100 µL purification injections, which is significant at these loading volumes and can contaminate collected fractions; keep the wash step in the sequence when transferring methods between columns.
Load & Lock columns are supplied in 1, 2, and 3 in id (27–75 mm) with stainless steel water jackets, and mobile packing stations exist separately for 1, 2, and 3 in id columns. The packing station must match the column id; a 3 in column cannot be packed on a 1 in station.
The purification configuration is an Agilent 1260 Infinity II Analytical LC extended with the 1260 Infinity II Analytical-Scale Fraction Collector (G1364F). Integration therefore requires the base analytical LC's detector signal and autosampler to trigger collection; plan the control software and cabling around the base LC, not around a standalone preparative controller.
Selection & Integration Q&A
Pick this system for gram-scale isolation up to 50 mg purified target at 1 mL/min typical and 10 mL/min max collection flow, with 75–100 µL purification injections. Choose the 1260 Infinity II Preparative LC System for larger UV-based prep loads, the 1220 for entry-level analytical-scale purification, and the Bio-Inert variant for metal-sensitive samples.
Agilent Load & Lock columns in 1, 2, or 3 in id (27–75 mm), packed in DAC or SAC mode on a mobile packing station matched to the column id, with the standard stainless steel water jacket connected. The G1364F fraction collector is required for collection; the base analytical LC alone only quantitates.
The Load & Lock columns, the mobile packing station (separate for 1, 2, and 3 in id), and the G1364F analytical-scale fraction collector are separate items from the base analytical LC. The optional LC/MSD XT detector and InfinityLab preparative supplies are also ordered separately; plan column and station purchases with the system.