Agilent Technologies 1260 Analytical-Scale Purification System | Preparative HPLC
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1260 Analytical-Scale Purification System | Preparative HPLC

Agilent Technologies 1260 Analytical-Scale Purification System | Preparative HPLC — Liquid chromatography.

The 1260 Analytical-Scale Purification System is a preparative HPLC configuration built around a 1260 Infinity II Analytical LC extended with the G1364F analytical-scale fraction collector. It targets gram-scale purification with 1–3 in id Load & Lock columns, 1 mL/min typical flow, and up to 10 mL/min for fraction collection. It bridges analytical LC and preparative LC for compound isolation at 50 mg purified target per run.

Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection

Model Column inner diameter, mmTypical flow rate, mL/minPlate count, Nth/meterRetention time, minCarryover, %Sample capacity
1260 Analytical-Scale Purification System | Preparative HPLC Current 1...314060615.18——
1220 Infinity II Analytical-Scale LC Purification System 4.61————
1260 Infinity Bio-Inert Analytical-Scale LC Purification System 1...314060615.18——
1260 Infinity II Manual Preparative LC System 1...314060615.18——
1260 Infinity II Preparative LC System | UV based Prep HPLC 1...314060615.185132
1260 Prime Bio Analytical-Scale Purification System 4.61——9×10⁻⁴6144
1290 Analytical-Scale LC Purification 1...314060615.18——
1290 Infinity Autoscale Preparative system 1...314060615.18——
1290 Infinity III 4.61——9×10⁻⁴6144
1290 Infinity II Preparative LC System 1...314060615.18——
Automated LC/MSD purification| High-precision| Complex mixtures 1...314060615.18——
Flexible HPLC/UHPLC, Prime Analytical-Scale Purification System 1...314060615.18——
High-throughput Purification | Drug discovery | Biological 1...314060615.18——
Preparative LC/MSD System | Enhanced Purification & Efficiency 1...314060615.18——

Full specifications

Core Performance & Functional Specifications
Plate Count 40606 Nth/meter
Retention Time 15.18 min
Total Run Time 13 minutes
Typical Flow Rate 1 mL/min
Productivity range mfr Micrograms Micrograms
Asymmetry mfr 1.27
Maximum flow rate for fraction collection mfr 10 mL/min
Injection volume for quantitation mfr 0.5 μL
Injection volume for purification mfr 75...100 μL
Needle wash mfr 10 s
Resolution (EP) — ZORBAX Eclipse Plus C18 mfr 13.1
Selectivity — ZORBAX Eclipse Plus C18 mfr 1.71
Resolution (EP) — InfinityLab Poroshell 120 mfr 16.3
Selectivity — InfinityLab Poroshell 120 mfr 1.73
Resolution (EP) — Pursuit XRs mfr 13.8
Selectivity — Pursuit XRs mfr 1.60
Maximum injection volume without significant coelution — Pursuit XRs mfr 100 μL
Maximum injection volume without significant coelution — Pursuit XRs (repeated loading) mfr 80 μL
Purity of collected fractions mfr 99
Recovery mfr 96...97
Recovery — Pursuit XRs (repeated loading) mfr 97
Maximum purified target compound mfr 50 mg
Sample concentration — HBA mfr 8 mg/mL
Sample concentration — target compound mfr 40 mg/mL
Dimensions, Weight & Mechanical Design
Column Inner Diameter 1...3 in
Peak width (10%) — ZORBAX Eclipse Plus C18 mfr 0.085
Peak width (10%) — InfinityLab Poroshell 120 mfr 0.065
Peak width (10%) — Pursuit XRs mfr 0.085

Description

Construction and series positioning

Behavior under load and in different modes

Installation, connection, and operation

Integration & Operating Notes

Process Limits
Keep fraction collection flow at or below 10 mL/min

The analytical-scale fraction collector is rated for a maximum of 10 mL/min during collection. Exceeding this during a purification run risks fraction loss, carryover, or collector overflow; scale the gradient and column id so the collection step stays within this ceiling even though the analytical LC pump may support higher analytical flows.

Factory Specification Sheet; Technical Overview 5994-2829EN
Process Limits
Match injection volume to the column and loading mode

Purification injections of 75–100 µL are intended for the Load & Lock column configuration; on Pursuit XRs the maximum without significant coelution is 100 µL, dropping to 80 µL on repeated loading. Quantitation injections are 0.5 µL. Exceeding the column-specific loading limit degrades resolution and purity of collected fractions.

Factory Specification Sheet; Technical Overview 5994-2829EN
Maintenance
Allow the 10 s needle wash before each purification injection

The method includes a 10 s needle wash. Skipping or shortening it in method development risks carryover between the 75–100 µL purification injections, which is significant at these loading volumes and can contaminate collected fractions; keep the wash step in the sequence when transferring methods between columns.

Factory Specification Sheet
Mounting
Select the packing station by column inner diameter

Load & Lock columns are supplied in 1, 2, and 3 in id (27–75 mm) with stainless steel water jackets, and mobile packing stations exist separately for 1, 2, and 3 in id columns. The packing station must match the column id; a 3 in column cannot be packed on a 1 in station.

Brochure 5994-3907EN Load & Lock Columns
Control & I/O
Fraction collector is an extension of the analytical LC

The purification configuration is an Agilent 1260 Infinity II Analytical LC extended with the 1260 Infinity II Analytical-Scale Fraction Collector (G1364F). Integration therefore requires the base analytical LC's detector signal and autosampler to trigger collection; plan the control software and cabling around the base LC, not around a standalone preparative controller.

Technical Overview 5994-2829EN

Selection & Integration Q&A

When should I choose the 1260 Analytical-Scale Purification System instead of the 1260 Infinity II Preparative LC System or the 1220 Infinity II Analytical-Scale system?

Pick this system for gram-scale isolation up to 50 mg purified target at 1 mL/min typical and 10 mL/min max collection flow, with 75–100 µL purification injections. Choose the 1260 Infinity II Preparative LC System for larger UV-based prep loads, the 1220 for entry-level analytical-scale purification, and the Bio-Inert variant for metal-sensitive samples.

What column and packing hardware must be in place before this system can run a purification?

Agilent Load & Lock columns in 1, 2, or 3 in id (27–75 mm), packed in DAC or SAC mode on a mobile packing station matched to the column id, with the standard stainless steel water jacket connected. The G1364F fraction collector is required for collection; the base analytical LC alone only quantitates.

What is not included in the base delivery that I need to plan for?

The Load & Lock columns, the mobile packing station (separate for 1, 2, and 3 in id), and the G1364F analytical-scale fraction collector are separate items from the base analytical LC. The optional LC/MSD XT detector and InfinityLab preparative supplies are also ordered separately; plan column and station purchases with the system.

Dimensional Drawings & Technical Documentation

Technical documentation