Agilent Technologies 1290 Infinity II Preparative LC System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1290 Infinity II Preparative LC System

Agilent Technologies 1290 Infinity II Preparative LC System — Liquid chromatography with Pumping speed 0.012 m³/h.

The 1290 Infinity II Preparative LC System is a preparative-scale HPLC platform configured for 1–3 inch id columns, distinguishing it from analytical-scale siblings in the series. It accommodates preparative column dimensions, bridging method development and scale-up purification.

Pumping speed
0.012 m³/h

Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection

Model Column inner diameter, mmTypical flow rate, mL/minPlate count, Nth/meterRetention time, minCarryover, %Sample capacity
1290 Infinity II Preparative LC System Current 1...314060615.18——
1220 Infinity II Analytical-Scale LC Purification System 4.61————
1260 Analytical-Scale Purification System | Preparative HPLC 1...314060615.18——
1260 Infinity Bio-Inert Analytical-Scale LC Purification System 1...314060615.18——
1260 Infinity II Manual Preparative LC System 1...314060615.18——
1260 Infinity II Preparative LC System | UV based Prep HPLC 1...314060615.185132
1260 Prime Bio Analytical-Scale Purification System 4.61——9×10⁻⁴6144
1290 Analytical-Scale LC Purification 1...314060615.18——
1290 Infinity Autoscale Preparative system 1...314060615.18——
1290 Infinity III 4.61——9×10⁻⁴6144
Automated LC/MSD purification| High-precision| Complex mixtures 1...314060615.18——
Flexible HPLC/UHPLC, Prime Analytical-Scale Purification System 1...314060615.18——
High-throughput Purification | Drug discovery | Biological 1...314060615.18——
Preparative LC/MSD System | Enhanced Purification & Efficiency 1...314060615.18——

Full specifications

Core Performance & Functional Specifications
Pumping speed 200 mL/min
Plate Count 40606 Nth/meter
Retention Time 15.18 min
Typical Flow Rate 1 mL/min
Productivity range mfr Grams Grams
Asymmetry mfr 1.27
Packing asymmetry mfr 1.30
Packing station air pressure mfr 6 bar
SAC packing pressure (example) mfr 666 psi
DAC packing pressure (example) mfr 1015 psi
Sorbent particle size for DAC mfr 8...15 μm
Sorbent particle size for SAC mfr 10 larger
pressure at 50 mL/min mfr 600 bar
pressure at 200 mL/min mfr 420 bar
maximum flow rate (1260) mfr 50 mL/min
sample capacity (Open-Bed) mfr 864 samples
fraction capacity (Open-Bed) mfr 432 fractions
maximum fraction capacity mfr 1296 fractions
fractions per module (1260) mfr 216 fractions
expandable fraction capacity (1260) mfr 648 fractions
injection volume (1260 sampler) mfr 3.6 mL
sample capacity (1260 sampler) mfr 132 samples
sample loading increase (Load & Lock) mfr 20
Dimensions, Weight & Mechanical Design
Column Inner Diameter 1...3 in
Column tube length used for slurry packing mfr 60 less
maximum column inner diameter (1290) mfr 50 mm
maximum column inner diameter (1260) mfr 30 mm

Description

Construction and positioning

Performance characteristics

Installation and operation

Integration & Operating Notes

Maintenance
Regular column packing and maintenance required

Load & Lock columns in DAC or SAC modes require periodic packing and maintenance using the mobile packing stations available for 1, 2, and 3 in id columns. Follow the column manual for packing procedures and service intervals to maintain separation performance.

Load & Lock Columns 5994-3907EN
Integration
Compatible with InfinityLab preparative modules

The system integrates with preparative modules such as column organizer, column compartment, manual injector, open-bed sampler/collector, detectors, fraction collectors, and LC/MSD XT. Ensure all modules are from the InfinityLab portfolio for compatibility.

Brochure InfinityLab LC Purification Solutions 5991-9154EN

Selection & Integration Q&A

When should I choose the 1290 Infinity II Preparative LC System over the 1260 Infinity II Manual Preparative LC System or analytical-scale siblings?

Choose the 1290 Infinity II Preparative LC System when you need automated preparative purification with columns from 1 to 3 inches id and integration with InfinityLab modules. The 1260 Infinity II Manual Preparative LC System is for manual operation, while analytical-scale siblings (1220, 1260 Analytical-Scale) are limited to smaller columns and lower sample loads.

What are the requirements for columns and peripheral modules to integrate with this system?

The system requires preparative columns with 1–3 inch inner diameters, such as Agilent Load & Lock columns in DAC or SAC mode with stainless steel water jackets. Peripheral modules (column organizer, fraction collector, detectors, LC/MSD XT) must be from the InfinityLab portfolio to ensure compatibility and proper control.

Are there any mounting or environmental limits specified for this system?

The verified facts do not specify mounting or environmental limits. Refer to the instrument's site preparation guide and user manual for bench space, power, and environmental requirements. The system is typically installed on a stable laboratory bench with adequate ventilation.

What maintenance is required, and what accessories are not included in the base delivery?

Regular maintenance includes column packing and replacement using mobile packing stations for 1, 2, and 3 in id columns. The base system does not include columns, packing stations, or fraction collectors; these must be ordered separately. Refer to the column manual for service intervals.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
Purify Your Way: Flexible Column Solutions
Brochure ·2,7 МБ ·12 pp.
View PDF
PDF
Purify Your Samples with Agilent Infinity II Purification Systems
Brochure ·2,0 МБ ·16 pp.
View PDF