Agilent Technologies Preparative LC/MSD System | Enhanced Purification & Efficiency
Agilent Technologies Preparative LC/MSD System | Enhanced Purification & Efficiency — Liquid chromatography.
The Preparative LC/MSD System is a preparative-scale HPLC configuration built around the 1260 Infinity II Preparative Binary Pump, Preparative Autosampler, Variable Wavelength Detector and LC/MSD, with valve-based or open-bed fraction collection. It is distinguished within the series by mass-directed detection for fraction purity and recovery, and serves as the purification stage between analytical method development and isolated compound recovery.
Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection
Full specifications
| Detection wavelength | 254 nm |
| Fraction Purity | 97 % |
| Fraction Recovery | 96 % |
| Plate Count | 40606 Nth/meter |
| Retention Time | 15.18 min |
| Typical Flow Rate | 1 mL/min |
| Uv Threshold | 1 mAU/s |
| Productivity range mfr | Micrograms Micrograms |
| Asymmetry mfr | 1.27 |
| Column inside diameter range mfr | 9.4 mm |
| Gradient end point mfr | 3.50 % B |
| Stop time mfr | 5.10 minutes |
| Membrane pore size mfr | 0.22 μm |
| Column Inner Diameter | 1...3 in |
Description
Construction and series positioning
- The system is assembled from 1260 Infinity II preparative modules: Preparative Binary Pump, Preparative Autosampler (G7157A), Variable Wavelength Detector, and either the Preparative Valve-Based Fraction Collector or the 1290 Infinity II Preparative Open-Bed Fraction Collector, with the Agilent LC/MSD (G6125B) providing mass detection.
- Within the series, this is the mass-directed preparative configuration; the 1220 Infinity II and 1260 Analytical-Scale Purification Systems are analytical-scale alternatives, the 1260 Infinity Bio-Inert variant is for biological samples, and the 1260 Infinity II Manual Preparative LC System is a manual-injection preparative option without the LC/MSD.
- Column hardware compatible with the system includes Agilent Load & Lock columns in 1 to 3 in inside diameter (27 to 75 mm), available in dynamic axial compression (DAC) and static axial compression (SAC) modes with standard stainless steel water jackets.
Behavior and performance facts
- Reported performance for the preparative workflow includes fraction purity of 97 % and fraction recovery of 96 %, with a plate count of 40606 N/m and retention time of 15.18 min at a typical flow rate of 1 mL/min.
- Detection is at 254 nm with a UV threshold of 1 mAU/s; the gradient end point is 3.50 % B and stop time is 5.10 min.
- Column inside diameter range is 9.4 mm; asymmetry is 1.27. Membrane pore size of 0.22 µm is specified for filtration.
Installation, control and operation
- The system is controlled through OpenLAB CDS ChemStation software, which coordinates the binary pump, autosampler, detector, fraction collector and LC/MSD.
- Fraction collection can be valve-based or open-bed; the choice determines the collection vessel format and the fraction collector module installed.
- The LC/MSD adds mass-triggered fraction collection to the UV-based collection workflow.
Integration & Operating Notes
Load & Lock columns are offered in 1, 2 and 3 in inside diameters (27 to 75 mm) in both DAC and SAC modes; the packing station and column jacket must be selected for the same id and compression mode, otherwise the column cannot be packed or installed on the system.
The UV threshold is set at 1 mAU/s and the LC/MSD provides mass-triggered collection; the OpenLAB CDS ChemStation method must define which trigger governs the valve or open-bed collector so that fractions are not cut on the wrong signal.
The specified membrane pore size is 0.22 µm; sample and mobile-phase streams should be filtered to this rating to protect the preparative column and reduce detector baseline noise during long purification runs.
The system is assembled from separate 1260 Infinity II preparative modules and the LC/MSD; each module requires its own power connection and LAN/control link to the OpenLAB CDS ChemStation workstation, so the bench layout must provide for the full module stack.
Selection & Integration Q&A
Choose this system when mass-directed fraction collection and the reported 97 % purity / 96 % recovery are required. The Manual Preparative system lacks the LC/MSD and autosampler; the 1220/1260 analytical-scale systems are for method development rather than preparative isolation.
Load & Lock columns in 1–3 in id (27–75 mm) in DAC or SAC mode with the matching packing station, plus either the 1260 Infinity II Preparative Valve-Based Fraction Collector or the 1290 Infinity II Preparative Open-Bed Fraction Collector; the LC/MSD (G6125B) is a separate module.
The base system does not include Load & Lock columns, packing stations, 0.22 µm filtration membranes, or replacement fraction-collection vessels; these must be ordered separately, and the OpenLAB CDS ChemStation software license is a separate item.