Agilent Technologies Preparative LC/MSD System | Enhanced Purification & Efficiency
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Preparative LC/MSD System | Enhanced Purification & Efficiency

Agilent Technologies Preparative LC/MSD System | Enhanced Purification & Efficiency — Liquid chromatography.

The Preparative LC/MSD System is a preparative-scale HPLC configuration built around the 1260 Infinity II Preparative Binary Pump, Preparative Autosampler, Variable Wavelength Detector and LC/MSD, with valve-based or open-bed fraction collection. It is distinguished within the series by mass-directed detection for fraction purity and recovery, and serves as the purification stage between analytical method development and isolated compound recovery.

Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection

Model Column inner diameter, mmTypical flow rate, mL/minPlate count, Nth/meterRetention time, minCarryover, %Sample capacity
Preparative LC/MSD System | Enhanced Purification & Efficiency Current 1...314060615.18——
1220 Infinity II Analytical-Scale LC Purification System 4.61————
1260 Analytical-Scale Purification System | Preparative HPLC 1...314060615.18——
1260 Infinity Bio-Inert Analytical-Scale LC Purification System 1...314060615.18——
1260 Infinity II Manual Preparative LC System 1...314060615.18——
1260 Infinity II Preparative LC System | UV based Prep HPLC 1...314060615.185132
1260 Prime Bio Analytical-Scale Purification System 4.61——9×10⁻⁴6144
1290 Analytical-Scale LC Purification 1...314060615.18——
1290 Infinity Autoscale Preparative system 1...314060615.18——
1290 Infinity III 4.61——9×10⁻⁴6144
1290 Infinity II Preparative LC System 1...314060615.18——
Automated LC/MSD purification| High-precision| Complex mixtures 1...314060615.18——
Flexible HPLC/UHPLC, Prime Analytical-Scale Purification System 1...314060615.18——
High-throughput Purification | Drug discovery | Biological 1...314060615.18——

Full specifications

Core Performance & Functional Specifications
Detection wavelength 254 nm
Fraction Purity 97 %
Fraction Recovery 96 %
Plate Count 40606 Nth/meter
Retention Time 15.18 min
Typical Flow Rate 1 mL/min
Uv Threshold 1 mAU/s
Productivity range mfr Micrograms Micrograms
Asymmetry mfr 1.27
Column inside diameter range mfr 9.4 mm
Gradient end point mfr 3.50 % B
Stop time mfr 5.10 minutes
Membrane pore size mfr 0.22 μm
Dimensions, Weight & Mechanical Design
Column Inner Diameter 1...3 in

Description

Construction and series positioning

Behavior and performance facts

Installation, control and operation

Integration & Operating Notes

Process Limits
Column hardware must match 1–3 in id and compression mode

Load & Lock columns are offered in 1, 2 and 3 in inside diameters (27 to 75 mm) in both DAC and SAC modes; the packing station and column jacket must be selected for the same id and compression mode, otherwise the column cannot be packed or installed on the system.

Agilent Load & Lock Columns brochure 5994-3907EN
Control & I/O
Fraction collection triggered by UV threshold or mass signal

The UV threshold is set at 1 mAU/s and the LC/MSD provides mass-triggered collection; the OpenLAB CDS ChemStation method must define which trigger governs the valve or open-bed collector so that fractions are not cut on the wrong signal.

Technical Overview 5991-8159EN, 1260 Infinity II Preparative LC/MSD System
Maintenance
0.22 µm membrane filtration required before preparative injection

The specified membrane pore size is 0.22 µm; sample and mobile-phase streams should be filtered to this rating to protect the preparative column and reduce detector baseline noise during long purification runs.

Factory Specification Sheet
Electrical
Module-level power and communication configuration

The system is assembled from separate 1260 Infinity II preparative modules and the LC/MSD; each module requires its own power connection and LAN/control link to the OpenLAB CDS ChemStation workstation, so the bench layout must provide for the full module stack.

Technical Overview 5991-8159EN

Selection & Integration Q&A

When should I choose the Preparative LC/MSD System instead of the 1260 Infinity II Manual Preparative LC System or the analytical-scale purification systems?

Choose this system when mass-directed fraction collection and the reported 97 % purity / 96 % recovery are required. The Manual Preparative system lacks the LC/MSD and autosampler; the 1220/1260 analytical-scale systems are for method development rather than preparative isolation.

What column hardware and collection modules must be ordered alongside the base system?

Load & Lock columns in 1–3 in id (27–75 mm) in DAC or SAC mode with the matching packing station, plus either the 1260 Infinity II Preparative Valve-Based Fraction Collector or the 1290 Infinity II Preparative Open-Bed Fraction Collector; the LC/MSD (G6125B) is a separate module.

What maintenance and consumables are not included in the base delivery?

The base system does not include Load & Lock columns, packing stations, 0.22 µm filtration membranes, or replacement fraction-collection vessels; these must be ordered separately, and the OpenLAB CDS ChemStation software license is a separate item.

Dimensional Drawings & Technical Documentation

Technical documentation