No photo available yet
Agilent Technologies 1260 Prime Bio Analytical-Scale Purification System
Agilent Technologies 1260 Prime Bio Analytical-Scale Purification System — Liquid chromatography.
The 1260 Prime Bio Analytical-Scale Purification System is a bio-inert analytical HPLC configuration built around a 4.6 mm column format, positioned between the 1220 Infinity II and 1260 Infinity II Bio-Inert systems in the series. It delivers 1 mL/min typical flow with 9 ppm carryover and supports up to 6144 samples for microgram-scale purification.
Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection
Full specifications
| Carryover | 9 ppm |
| Sample Capacity | 6144 samples |
| Typical Flow Rate | 1 mL/min |
| Productivity range mfr | Micrograms Micrograms |
| Column Inner Diameter | 4.6 mm |
Description
Construction and series positioning
- Bio-inert flow path configuration of the 1260 Prime platform, specified for analytical-scale purification with 4.6 mm internal-diameter columns.
- Sits above the 1220 Infinity II Analytical-Scale LC Purification System and alongside the 1260 Infinity II Bio-Inert and 1260 Analytical-Scale Purification systems; the 1260 Infinity II Manual Preparative LC System is the manual preparative alternative.
- Sample capacity of 6144 samples and productivity range expressed in micrograms define the analytical, not preparative, scale of this modification.
Performance envelope
- Typical flow rate 1 mL/min at the 4.6 mm column format; carryover 9 ppm.
- No digitized curve points were supplied, so pressure-flow behavior cannot be characterized beyond the listed values.
Integration and operation
- The attached brochure digests list no ordering codes, electrical ratings, or control details; installation and control specifics must be taken from the instrument manual, not from this card.
Integration & Operating Notes
The system is specified around 4.6 mm internal-diameter columns; using preparative-bore columns requires a different series member such as the 1260 Infinity II Manual Preparative LC System, since the analytical-scale flow path and sample handling here are matched to the 4.6 mm format.
Selection & Integration Q&A
Choose this model for bio-inert analytical purification on 4.6 mm ID columns at 1 mL/min with 9 ppm carryover and 6144-sample capacity. The 1260 Infinity II Manual Preparative LC System is the manual preparative alternative; the 1260 Infinity II Bio-Inert is the other bio-inert analytical option in the series.
The supplied facts list no electrical ratings, detector, fraction collector, or fitting specifications, so drive, power supply, controller, and mating-flange compatibility cannot be confirmed from this card. Column format is fixed at 4.6 mm ID; confirm all other module compatibility against the instrument manual before ordering.
The brochure digests contain no maintenance intervals, error codes, or accessory lists, and no cables, fittings, or consumables are identified as included or excluded. Service scheduling and replacement-part selection require the instrument manual; the supplied documents do not define them.