No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1260 Prime Bio Analytical-Scale Purification System

Agilent Technologies 1260 Prime Bio Analytical-Scale Purification System — Liquid chromatography.

The 1260 Prime Bio Analytical-Scale Purification System is a bio-inert analytical HPLC configuration built around a 4.6 mm column format, positioned between the 1220 Infinity II and 1260 Infinity II Bio-Inert systems in the series. It delivers 1 mL/min typical flow with 9 ppm carryover and supports up to 6144 samples for microgram-scale purification.

Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection

Model Column inner diameter, mmTypical flow rate, mL/minPlate count, Nth/meterRetention time, minCarryover, %Sample capacity
1260 Prime Bio Analytical-Scale Purification System Current 4.61——9×10⁻⁴6144
1220 Infinity II Analytical-Scale LC Purification System 4.61————
1260 Analytical-Scale Purification System | Preparative HPLC 1...314060615.18——
1260 Infinity Bio-Inert Analytical-Scale LC Purification System 1...314060615.18——
1260 Infinity II Manual Preparative LC System 1...314060615.18——
1260 Infinity II Preparative LC System | UV based Prep HPLC 1...314060615.185132
1290 Analytical-Scale LC Purification 1...314060615.18——
1290 Infinity Autoscale Preparative system 1...314060615.18——
1290 Infinity III 4.61——9×10⁻⁴6144
1290 Infinity II Preparative LC System 1...314060615.18——
Automated LC/MSD purification| High-precision| Complex mixtures 1...314060615.18——
Flexible HPLC/UHPLC, Prime Analytical-Scale Purification System 1...314060615.18——
High-throughput Purification | Drug discovery | Biological 1...314060615.18——
Preparative LC/MSD System | Enhanced Purification & Efficiency 1...314060615.18——

Full specifications

Core Performance & Functional Specifications
Carryover 9 ppm
Sample Capacity 6144 samples
Typical Flow Rate 1 mL/min
Productivity range mfr Micrograms Micrograms
Dimensions, Weight & Mechanical Design
Column Inner Diameter 4.6 mm

Description

Construction and series positioning

Performance envelope

Integration and operation

Integration & Operating Notes

Process Limits
Column format fixed at 4.6 mm ID for this modification

The system is specified around 4.6 mm internal-diameter columns; using preparative-bore columns requires a different series member such as the 1260 Infinity II Manual Preparative LC System, since the analytical-scale flow path and sample handling here are matched to the 4.6 mm format.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the 1260 Prime Bio Analytical-Scale Purification System instead of the 1260 Infinity II Bio-Inert or the 1260 Infinity II Manual Preparative LC System?

Choose this model for bio-inert analytical purification on 4.6 mm ID columns at 1 mL/min with 9 ppm carryover and 6144-sample capacity. The 1260 Infinity II Manual Preparative LC System is the manual preparative alternative; the 1260 Infinity II Bio-Inert is the other bio-inert analytical option in the series.

What adjacent system parts must be matched to this system, and what compatibility data is available?

The supplied facts list no electrical ratings, detector, fraction collector, or fitting specifications, so drive, power supply, controller, and mating-flange compatibility cannot be confirmed from this card. Column format is fixed at 4.6 mm ID; confirm all other module compatibility against the instrument manual before ordering.

What maintenance schedule and consumables apply, and what is not included in base delivery?

The brochure digests contain no maintenance intervals, error codes, or accessory lists, and no cables, fittings, or consumables are identified as included or excluded. Service scheduling and replacement-part selection require the instrument manual; the supplied documents do not define them.

Dimensional Drawings & Technical Documentation

Technical documentation