Agilent Technologies 1290 Analytical-Scale LC Purification
Agilent Technologies 1290 Analytical-Scale LC Purification — Liquid chromatography.
The 1290 Analytical-Scale LC Purification System is a benchtop liquid chromatography platform configured for analytical-scale purification. It operates at typical analytical flow rates around 1 mL/min, achieving plate counts near 40,600 N/m and retention times around 15 min, distinguishing it from preparative-scale siblings in the 1260 and 1220 lines. It serves as the purification front-end in drug-discovery and compound-isolation workflows where microgram-to-milligram fractions are recovered from analytical separations.
Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection
Full specifications
| Plate Count | 40606 Nth/meter |
| Retention Time | 15.18 min |
| Typical Flow Rate | 1 mL/min |
| Productivity range mfr | Micrograms Micrograms |
| Asymmetry mfr | 1.27 |
| Column Inner Diameter | 1...3 in |
Description
Construction and series positioning
- The 1290 Analytical-Scale LC Purification System sits at the analytical end of Agilent's InfinityLab purification portfolio, which also spans the 1220 Infinity II, 1260 Infinity, 1260 Infinity Bio-Inert, and 1260 Infinity II Manual Preparative systems.
- Unlike the preparative siblings, this modification is intended for analytical-scale injections and fraction volumes in the microgram range rather than gram-scale loading.
Behavior under load
- At a typical flow rate of 1 mL/min, the system resolves peaks with plate counts around 40,600 N/m and retention times near 15.18 min, with asymmetry measured at 1.27 — indicating near-symmetric peak shape under standard analytical conditions.
Installation and operation
- The system is a benchtop LC platform; the brochure digest lists preparative modules (column organizer, column compartment, manual injector, open-bed sampler/collector, detectors, fraction collectors, LC/MSD XT) as part of the wider portfolio, not necessarily included in this model.
Integration & Operating Notes
The 1 mL/min typical flow rate applies to the analytical configuration; larger columns require proportionally higher flow to maintain linear velocity. Operating a large column at analytical flow will produce broad peaks and long retention times, while overdriving a small column risks excessive backpressure.
The InfinityLab portfolio lists detectors, fraction collectors, and the LC/MSD XT as distinct modules. Confirm which modules are included in the base delivery of this analytical-scale configuration, since fraction collection hardware and detectors may need to be specified separately.
Selection & Integration Q&A
Choose the 1290 when your purification loads are in the microgram range and you need analytical-resolution separations (≈40,600 N/m, asymmetry 1.27) at ~1 mL/min. Step up to a 1260 Preparative system for gram-scale loading, or down to the 1220 Infinity II for routine analytical purification with simpler module sets.
Detectors, fraction collectors, the LC/MSD XT, and the mobile packing station are listed as separate portfolio modules and are not part of the base analytical-scale system. Column packing and repacking require the matching station; plan for consumable columns, fittings, and solvent lines as separately ordered items.