Peter Huber Kältemaschinenbau CS 100 by Van der Heijden
Peter Huber Kältemaschinenbau CS 100 by Van der Heijden — Recirculating chillers with Noise level 70 dB.
The CS 100 is a three-phase 400 V circulating chiller with a 37 l bath and a working range of -20 to 15 °C, positioned as the smallest and quietest unit in the Cs Chiller series. It requires a 160–175 l loop fill and a 5–32 °C plant room, and serves industrial process refrigeration with R-449A refrigerant.
Peter Huber Kältemaschinenbau Cs Chiller Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Minimum fill volume, m³ | Power supply | Pump connection | Temperature range, °C |
|---|---|---|---|---|---|---|
| CS 100 by Van der Heijden Current | 70 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 100-H by Van der Heijden | 71 | 5–32 | 0.175 | 400V 3~ 50Hz | G3/4 AG male | -20–85 |
| CS 200 by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–15 |
| CS 200-H by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–85 |
| CS 20-H by Van der Heijden | 57 | 5–32 | 0.024 | 230V 1~ 50Hz | G3/8 AG male | -20–85 |
| CS 25 by Van der Heijden | 60 | 5–32 | 0.024 | 230V 1~ 50Hz | G1/2 AG male | -20–15 |
| CS 50 by Van der Heijden | 63 | 5–32 | 0.1 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 75 by Van der Heijden | 66 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| Huber CS 200-H | 78 | 5–32 | 0.225 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 25 | 60 | 5–32 | 0.024 | 208V 2~ 60Hz | G1/2 AG male | -20–15 |
| Huber CS 250HT OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G3/4 AG male | 10–22 |
| Huber CS 330-H OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550-H OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550 OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–15 |
| Huber LCS 80 | 77 | -20–50 | 0.04 | 460V 3~ 60Hz | G1 AG male | -45–15 |
Full specifications
| Noise level | 70 dB(A) |
| Bath volume | 37 l |
| Minimum fill volume | 160 l |
| Pump connection | G3/4 AG male |
| Temperature range | -20...15 °C |
| Weight | 265 kg |
| Current consumption | 12 A |
| Power supply | 400V 3~ 50Hz |
| Digital interface | RS232 |
| Ambient temperature limit | 5...32 °C |
| Protection rating | IP52 |
| Safety class | I / NFL |
Description
Construction and series positioning
- The CS 100 is the base model of the Cs Chiller line; siblings CS 100-H, CS 125, CS 125-H and CS 200 step up in capacity and sound level (71–78 dB(A) versus 70 dB(A) here).
- It is a three-phase 400 V 3~ 50 Hz unit drawing 12 A, protected by a 3x16 A fuse, with IP52 protection and safety class I / NFL.
- The hydraulic circuit uses G3/4 male pump connections; the 37 l internal bath is distinct from the 160–175 l minimum system fill volume.
Behavior and media
- Working temperature range is -20 to 15 °C. Cooling capacity is rated at 20 °C ambient and falls as ambient rises; the permitted ambient window is 5–32 °C.
- The recommended thermofluid is a 50:50 water–monoethylene glycol mixture, which sets freeze protection and heat-transfer behavior.
- Refrigerant is R-449A (A1, H280); the unit is EN55011 Class A Group 1 and compliant with US-SNAP for industrial process refrigeration.
Installation and operation
- Flow rate is set by a manual bypass valve on the rear of the chiller, so rear access must remain clear.
- Three-phase devices below 63 A are supplied with a cable but no plug; the site must provide and fit the plug.
- Supply tolerance is ±5% voltage with ±2% frequency, not simultaneously at the unfavorable combination. An RS232 interface is provided for control/monitoring.
Integration & Operating Notes
The chiller is delivered with a cable but without a plug because it draws 12 A on a 400 V 3~ 50 Hz supply. The installer must size upstream protection to 3x16 A and provide a mating plug; voltage and frequency must stay within ±5% and ±2% respectively, and not at the unfavorable combination simultaneously.
The minimum filling capacity of 160 l (up to 175 l) is far larger than the 37 l internal bath, so the external loop, expansion volume and fluid quantity must be engineered before commissioning. The recommended thermofluid is a 50:50 water–monoethylene glycol mixture to match freeze protection and heat transfer.
Flow rate is adjusted via a manual bypass valve on the backside of the chiller, so the installation layout must leave the rear accessible for commissioning and later adjustment. The unit weighs 265 kg and produces about 70 dB(A), so floor loading and acoustic separation from occupied areas should be considered.
Cooling capacity is rated at 20 °C ambient and drops as ambient temperature rises, so the plant room must be kept within the 5–32 °C window and selection must use the actual room temperature rather than the 20 °C rating. Refrigerant R-449A is classified A1 with GHS H280, so ventilation and handling precautions follow that classification.
The unit is EN55011 Class A Group 1, intended for industrial environments; in residential areas additional EMC measures may be required. An RS232 interface is available for control and monitoring, and the equipment is compliant with US-SNAP for industrial process refrigeration, so the end use must match that application.
Selection & Integration Q&A
Pick the CS 100 when the -20 to 15 °C range and 37 l bath suffice and 70 dB(A) is the quietest option in the series; the CS 100-H, CS 125 and CS 200 step up in capacity and sound level (71–78 dB(A)).
Provide G3/4 female mating fittings for the G3/4 male pump connections, a 160–175 l loop filled with 50:50 water–monoethylene glycol, and a 400 V 3~ 50 Hz feed protected at 3x16 A with a site-fitted plug.
Operate within 5–32 °C ambient, knowing capacity is rated at 20 °C and falls as ambient rises. Keep the rear accessible for the manual bypass valve, allow for 265 kg weight and about 70 dB(A), and respect IP52 and Class A EMC.
The three-phase cable is supplied but the plug is not, and the thermofluid charge must be provided on site. Rear access is required for the bypass flow adjustment; no maintenance intervals or consumables are stated in the supplied datasheet.