Peter Huber Kältemaschinenbau Huber CS 550 OD
Peter Huber Kältemaschinenbau Huber CS 550 OD — Recirculating chillers with Noise level 79 dB.
The Huber CS 550 OD is a 460 V/60 Hz, three-phase outdoor-rated recirculating chiller with a -20…15 °C working range at 2 K stability. Its 160 l minimum fill and 125 l/min pump distinguish it from smaller Cs-series siblings, and it serves industrial process cooling where ambient conditions and refrigerant compliance are planned.
Peter Huber Kältemaschinenbau Cs Chiller Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Minimum fill volume, m³ | Power supply | Pump connection | Temperature range, °C |
|---|---|---|---|---|---|---|
| Huber CS 550 OD Current | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–15 |
| CS 100 by Van der Heijden | 70 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 100-H by Van der Heijden | 71 | 5–32 | 0.175 | 400V 3~ 50Hz | G3/4 AG male | -20–85 |
| CS 200 by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–15 |
| CS 200-H by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–85 |
| CS 20-H by Van der Heijden | 57 | 5–32 | 0.024 | 230V 1~ 50Hz | G3/8 AG male | -20–85 |
| CS 25 by Van der Heijden | 60 | 5–32 | 0.024 | 230V 1~ 50Hz | G1/2 AG male | -20–15 |
| CS 50 by Van der Heijden | 63 | 5–32 | 0.1 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 75 by Van der Heijden | 66 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| Huber CS 200-H | 78 | 5–32 | 0.225 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 25 | 60 | 5–32 | 0.024 | 208V 2~ 60Hz | G1/2 AG male | -20–15 |
| Huber CS 250HT OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G3/4 AG male | 10–22 |
| Huber CS 330-H OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550-H OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber LCS 80 | 77 | -20–50 | 0.04 | 460V 3~ 60Hz | G1 AG male | -45–15 |
Full specifications
| Noise level | 79 dB(A) (sound pressure level) |
| Bath volume | 37 l |
| Minimum fill volume | 160 l |
| Pump connection | G1 AG male |
| Temperature range | -20...15 °C |
| Temperature stability | 2 K |
| Weight | 540 kg (net) |
| Current consumption | 50 A (max.) |
| Power supply | 460V 3~ 60Hz |
| Digital interface | RS232 |
| Refrigerant | R-449A (1st stage; A1, H280) |
| Refrigerant quantity | 16 kg (1st stage) |
| Ambient temperature limit | -20...50 °C (permissible) |
| Safety class | I / NFL |
Description
Construction and series positioning
- The CS 550 OD is the largest modification in the Cs Chiller family shown here; siblings CS 100, CS 100-H, CS 125 and CS 125-H are smaller-capacity units with lower noise levels (70–75 dB(A) versus 79 dB(A) for this model).
- It is built for outdoor mounting down to -20 °C ambient and uses R-449A (A1, H280) in the first stage, with 16 kg charge and a CO2 equivalent of 22.35 t.
- Electrical components are IP54-rated; the unit is supplied with cable but without a plug for three-phase current below 63 A.
Working range and load behavior
- Temperature range is -20…15 °C with 2 K stability; the recommended thermofluid is a 50:50 water–monoethylene glycol mixture, which sets freeze protection and heat-transfer basis.
- Cooling capacity falls as ambient temperature rises, so selection must use the actual site ambient rather than a nominal rating.
- The pump delivers up to 125 l/min at up to 4.7 bar; flow can be matched to the external circuit via a manual bypass valve on the rear of the chiller.
- The external circuit requires a minimum filling capacity of 160 l (maximum 195 l, warning at 175 l), so fluid charge and expansion space must be planned around the loop.
Installation, control and operation
- A remote operating panel is connected via a 20 m cable, allowing the control point to be located away from the chiller.
- The RS232 interface provides serial communication; no other control interfaces are listed in the verified facts.
- Voltage and frequency tolerances are interdependent: -5% voltage with +2% frequency is not allowed, while -5% voltage with -2% frequency is allowed.
- The unit is classified EN55011 Class A Group 1, intended for industrial electromagnetic environments; the US-SNAP end-use is industrial process refrigeration.
Integration & Operating Notes
The chiller is supplied with cable but without a plug because its current consumption is below 63 A. The customer must provide a suitable plug and disconnecting means rated for the 460 V/60 Hz three-phase supply and the 50 A maximum current, and verify that the combined voltage/frequency tolerance rule is met at the point of connection.
Although the bath itself is 37 l, the minimum filling capacity for the system is 160 l, with a maximum of 195 l and a warning threshold at 175 l. The external circuit and expansion volume must be sized within these limits; operating below the minimum risks pump cavitation and poor temperature control, while exceeding the maximum leaves insufficient expansion space.
The recommended thermofluid is a 50:50 water–monoethylene glycol mixture. This ratio defines the freeze protection and heat-transfer basis for the -20…15 °C range; using plain water or a different concentration can cause freezing, corrosion or reduced heat transfer at low temperatures.
The unit is suitable for outside mounting down to -20 °C ambient, and its electrical components are IP54-rated. Installation planning must account for low ambient temperatures and possible freezing of heat-transfer fluid, and must not expose the electrical enclosure to conditions beyond IP54 (dust and water ingress).
The operating panel is connected via a 20 m cable, so the control point can be located away from the chiller but only within that cable reach. Plan cable routing and panel mounting accordingly; the RS232 interface provides serial communication for integration with a higher-level controller.
The unit contains 16 kg of R-449A with a CO2 equivalent of 22.35 t. This charge level typically triggers periodic refrigerant leak checks and record keeping in many jurisdictions. Service procedures must account for R-449A as a pressurized gas (H280), and leak response plans should be in place.
Selection & Integration Q&A
Choose the CS 550 OD when the external loop requires a minimum fill of 160 l and pump delivery up to 125 l/min at 4.7 bar, with a -20…15 °C range. Smaller siblings like the CS 125 have lower capacity and noise (75 dB(A) vs 79 dB(A)) and suit lower-volume circuits.
The unit requires 460 V/60 Hz three-phase with 50 A maximum current. It is supplied with cable but without a plug because current is below 63 A, so the site must provide a suitable plug and disconnect. Verify the combined voltage/frequency tolerance rule at the connection point.
Yes, it is suitable for outside mounting down to -20 °C ambient, with electrical components rated IP54. Cooling capacity drops as ambient temperature rises, so selection must use the actual site ambient. Freeze protection for the heat-transfer fluid must be planned for low ambient conditions.
The 16 kg R-449A charge (22.35 t CO2 equivalent) typically triggers periodic leak checks and record keeping. The base delivery includes a 20 m remote panel cable but no plug; the customer must provide the plug and disconnect. Recommended thermofluid (50:50 water–MEG) is not included.