The TC45 is an air-cooled immersion cooler with a stainless-steel condensing probe (48 mm dia. × 105 mm, 1050 mm flexible connection) and a 0.041 kg R-290 charge, covering -45 to 100 °C. It delivers 0.05 kW at -40 °C and 0.24 kW at 0 °C. It serves as a direct-contact cold trap or bath cooler in laboratory and pilot processes.
Peter Huber Kältemaschinenbau Eintauchkuehler Kuehlfallen Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Power supply | Refrigerant | Safety class | Temperature range, °C |
|---|---|---|---|---|---|---|
| TC45 Current | — | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| CT50 Single OLÉ | 59 | OLÉ | 220-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | III / FL | -50–50 |
| TC100 | 55 | ON-OFF-Regler | 220-240V 1~/2~ 50/60Hz | R-1150 (A3, H220) | I / NFL | -100–40 |
| TC100E-F | 55 | MPC | 110-120V 1~ 60Hz | R-1150 (A3, H220) | I / NFL | -100–40 |
| TC100-F | 58 | ON-OFF-Regler | 220-240V 1~/2~ 50/60Hz | R-1150 (A3, H220) | I / NFL | -100–40 |
| TC45E | — | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| TC45E-F | 54 | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| TC45-F | 59 | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| TC50 | — | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
| TC50E | — | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
| TC50E-F | 60 | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
| TC50-F | 60 | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
Full specifications
| Pump speed adjustable | no |
| Pump type | no pump |
| Temperature range | -45...100 °C |
| Dimensions (W x D x H) mfr | 190 x 295 x 360 mm |
| Refrigeration machine mfr | air-cooled, natural refrigerant |
| Weight | 16 kg |
| Power supply | 208-240V 1~/2~ 50/60Hz |
| Current consumption max. mfr | 1, 4 A (max.) |
| Controller | ON-OFF-controller |
| Refrigerant | R-290 (A3, H220) (1st stage) |
| Refrigerant quantity 1st stage mfr | 0, 041 kg (1st stage) |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity mfr | 0, 05 kW (at -40 °C) |
| Safety class | I / NFL |
Description
Construction and series positioning
The TC45 is a self-contained immersion cooler: a stainless-steel housing with two handles, an air-cooled refrigerating unit, and a flexible stainless-steel condensing probe. Its working range of -45 to 100 °C and ON-OFF controller distinguish it from larger siblings (TC100, TC100E, TC100E-F, CT50 Single OLÉ), which are oriented toward higher capacity or lower noise. The TC45 is the compact, low-charge option for direct probe immersion.
Behavior under load
The cooling capacity is strongly temperature-dependent: 0.24 kW at 0 °C, 0.18 kW at -20 °C, 0.1 kW at -30 °C, and 0.05 kW at -40 °C. Rated data apply at 20 °C room temperature; capacity falls as ambient rises. The refrigeration unit runs continuously rather than cycling, so the ON-OFF controller modulates the process rather than the compressor. The unit has no pump and no adjustable pump speed, so circulation must be provided externally if required.
Installation and operation
Supply is 208–240 V, 1~/2~, 50/60 Hz with a maximum current of 1.4 A; a country-specific plug must be specified at ordering. Voltage tolerance is ±5% only with ±2% frequency tolerance, and the combination -5% voltage with +2% frequency is not allowed. Ambient must stay within 5–40 °C. The R-290 (A3, H220) refrigerant charge is 0.041 kg, keeping F-gas obligations minimal, but ignition sources and ventilation must be controlled. EMC classification is Class A, Group 1 (industrial environment). Space requirements around the air-cooled condenser must be respected.
Integration & Operating Notes
The unit accepts 208–240 V at 50/60 Hz, but voltage may deviate only ±5% while frequency deviates ±2%, and the combination of -5% voltage with +2% frequency is explicitly not allowed. Verify site power quality before connection; a supply outside this window can prevent safe operation.
Capacity falls from 0.24 kW at 0 °C to 0.05 kW at -40 °C, so the heat load must be checked at the coldest setpoint, not at nominal. A load sized for 0 °C will be grossly undersized near -40 °C.
The probe is 48 mm nominal diameter and 105 mm long, with a 1050 mm flexible connection. Check the vessel opening, immersion depth, and routing of the flexible section before installation; the probe cannot be bent beyond the flexible connection.
The refrigerant is R-290 (propane, A3 flammable, H220) with a 0.041 kg charge. Although the charge is small, the installation area must be assessed for ignition sources and ventilation per the safety class I / NFL marking.
Single/two-phase devices are delivered with a power cable and a country-specific plug that must be specified at ordering. Without the correct plug, commissioning is delayed.
The controller is an ON-OFF type, while the refrigeration unit runs continuously. There is no pump and no pump-speed adjustment, so external circulation or agitation is needed if the process requires mixing.
Selection & Integration Q&A
Pick the TC45 when the load is small and the coldest setpoint is near -40 °C, where it delivers 0.05 kW. Choose a TC100-series sibling when higher capacity or lower noise (55 dB(A) vs. the TC45's compact format) is needed; the CT50 Single OLÉ is a different series with 59 dB(A).
It has no pump, so external circulation or agitation must be provided if the bath or trap needs mixing. A country-specific plug must be specified at ordering; the power cable is included but the plug type is not universal. No controller interface or drive is supplied.
The R-290 charge is only 0.041 kg, so leak checks are simple; no regular refrigerant top-up is specified. The base delivery excludes the country-specific plug unless ordered, and no pump or external circulation accessories are included. Consult the operating conditions for condenser-cleaning intervals.