Peter Huber Kältemaschinenbau TC100-F
Peter Huber Kältemaschinenbau TC100-F — Immersion coolers with Noise level 58 dB.
The TC100-F is an air-cooled two-stage immersion cooler with a 13 mm × 900 mm probe and 1150 mm flexible connection, rated for -100 to 40 °C using flammable A3 refrigerants (R-1270 first stage, R-1150 second stage). It is the -F variant of the TC100 series, distinguished by its fixed probe assembly for direct immersion into vessels and baths. It serves as a point-of-use cold source for small heat loads in laboratory and industrial processes requiring temperatures down to -100 °C.
Peter Huber Kältemaschinenbau Eintauchkuehler Kuehlfallen Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Power supply | Refrigerant | Safety class | Temperature range, °C |
|---|---|---|---|---|---|---|
| TC100-F Current | 58 | ON-OFF-Regler | 220-240V 1~/2~ 50/60Hz | R-1150 (A3, H220) | I / NFL | -100–40 |
| CT50 Single OLÉ | 59 | OLÉ | 220-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | III / FL | -50–50 |
| TC100 | 55 | ON-OFF-Regler | 220-240V 1~/2~ 50/60Hz | R-1150 (A3, H220) | I / NFL | -100–40 |
| TC100E-F | 55 | MPC | 110-120V 1~ 60Hz | R-1150 (A3, H220) | I / NFL | -100–40 |
| TC45 | — | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| TC45E | — | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| TC45E-F | 54 | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| TC45-F | 59 | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| TC50 | — | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
| TC50E | — | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
| TC50E-F | 60 | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
| TC50-F | 60 | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
Full specifications
| Noise level | 58 dB(A) |
| Pump speed adjustable | no |
| Pump type | no pump |
| Temperature range | -100...40 °C |
| Dimensions (W x D x H) mfr | 295 x 500 x 570 mm |
| Refrigeration machine mfr | air-cooled, natural refrigerant |
| Weight | 57 kg |
| Current consumption | 7 A (max.) |
| Power supply | 220-240V 1~/2~ 50/60Hz |
| Controller | ON-OFF-controller |
| Refrigerant | R-1270 (A3, H220) (1st stage) 2nd stage: R-1150 (A3, H220) |
| Refrigerant quantity 1st stage mfr | 0, 114 kg (1st stage) |
| Refrigerant quantity 2nd stage mfr | 0, 056 kg (2nd stage) |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity mfr | 0: 0, 16; -20: 0, 15; -30: 0, 14; -50: 0, 13; -6 (at °C) |
| Safety class | I / NFL |
Description
Construction and series positioning
- Two-stage cascade refrigeration system using R-1270 (A3, H220) in the first stage (0.114 kg charge) and R-1150 (A3, H220) in the second stage (0.056 kg charge); both are flammable natural refrigerants with GWP 0.
- Air-cooled condenser, no pump and no adjustable pump speed; the refrigeration unit runs continuously.
- The -F designation denotes the fixed probe configuration: 13 mm nominal diameter, 900 mm probe length, 1150 mm flexible connection. Sibling models TC100, TC100E and TC100E-F share the series but differ in configuration; the TC100-F is the variant with this specific probe assembly.
- Net weight 57 kg, overall dimensions 295 × 500 × 570 mm (W × D × H).
Behavior under load
- Cooling capacity at 20 °C room temperature: 0.16 kW at 0 °C, 0.15 kW at -20 °C, 0.14 kW at -30 °C, 0.13 kW at -50 °C, 0.12 kW at -60 °C, 0.12 kW at -80 °C, 0.07 kW at -90 °C and 0.01 kW at -100 °C.
- Capacity falls sharply below -80 °C; the -100 °C endpoint is practical only for very small heat loads.
- Published capacities are valid at 20 °C ambient and may drop at higher room temperature.
- Control is ON-OFF (ON-OFF-Regler); there is no proportional or PID modulation.
Installation, connection and operation
- Power supply: 220–240 V, single- or two-phase, 50/60 Hz; maximum current 7 A; fuse 10–16 A.
- Voltage and frequency tolerances are coupled: ±5% voltage only with ±2% frequency; combinations such as -5% voltage with +2% frequency are not permitted.
- Single- and two-phase units are delivered with a power cable and country-specific plug that must be specified at ordering.
- Ambient operating range 5–40 °C; space requirements around the air-cooled unit must be respected for heat rejection and service access.
- EMC classification Class A, Group 1 to EN55011: intended for industrial environments; may cause interference in residential areas.
- Pressure equipment category Art. 4.3 PED.
Integration & Operating Notes
At -90 °C only 0.07 kW and at -100 °C only 0.01 kW remain available, so the lowest temperatures are usable only with very small heat loads. Size the process heat load against the capacity at the actual setpoint, not at 0 °C.
A ±5% voltage deviation is permitted only with ±2% frequency deviation; combinations such as -5% voltage with +2% frequency are explicitly not allowed. Verify the site supply envelope before connection to avoid operating outside the permitted range.
Single- and two-phase devices (100 V to 240 V) are delivered with a power cable and a country-specific plug that must be stated when ordering. Plan the order configuration and the site receptacle accordingly.
The air-cooled unit may only be operated with ambient temperature between 5 °C and 40 °C, and cooling capacity is published at 20 °C room temperature and may drop as ambient rises. Keep the installation location within this range and respect space requirements for heat rejection.
Both circuits use flammable A3 refrigerants: R-1270 (0.114 kg) in the first stage and R-1150 (0.056 kg) in the second stage. Ventilation, ignition-source control and handling procedures must account for A3 classification at the installation site.
The controller is an ON-OFF type and the unit has no pump and no adjustable pump speed. Process control must tolerate the resulting temperature cycling, and circulation, if required, must be provided externally.
The refrigeration unit works continuously, so heat rejection, noise (58 dB(A)) and wear are continuous during operation. Plan energy and heat-load budgets for uninterrupted running rather than intermittent duty.
Selection & Integration Q&A
Choose the TC100-F when the application needs a fixed 13 mm × 900 mm probe with 1150 mm flexible connection for direct immersion. Other TC100 series variants differ in configuration; select the variant whose probe or interface matches your vessel and routing.
Provide 220–240 V single- or two-phase 50/60 Hz with a 10–16 A fuse; maximum current is 7 A. Voltage and frequency tolerances are coupled (±5% V only with ±2% Hz), and the country-specific plug must be specified at ordering.
Install only where ambient stays between 5 °C and 40 °C, with space for air-cooled heat rejection. It is EMC Class A for industrial environments, uses flammable A3 refrigerants, and the refrigeration unit runs continuously.
Single- and two-phase units ship with a power cable and country-specific plug, which must be specified at ordering. No pump is fitted, so any circulation must be provided externally; confirm probe fit (13 mm × 900 mm, 1150 mm flexible connection) before installation.