Peter Huber Kältemaschinenbau TC50E-F
Peter Huber Kältemaschinenbau TC50E-F — Immersion coolers with Noise level 60 dB.
The TC50E-F is an air-cooled immersion cooler with a 900 mm Pt100 probe, covering -50 to 50 °C using flammable R-290 refrigerant. It is the compact 0.2 kW-at--30 °C member of the TC series, distinguished from the TC100/TC100E variants by lower capacity and a 60 dB(A) noise level. It is used for direct low-temperature cooling of baths and process fluids where no pump is required.
Peter Huber Kältemaschinenbau Eintauchkuehler Kuehlfallen Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Power supply | Refrigerant | Safety class | Temperature range, °C |
|---|---|---|---|---|---|---|
| TC50E-F Current | 60 | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
| CT50 Single OLÉ | 59 | OLÉ | 220-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | III / FL | -50–50 |
| TC100 | 55 | ON-OFF-Regler | 220-240V 1~/2~ 50/60Hz | R-1150 (A3, H220) | I / NFL | -100–40 |
| TC100E-F | 55 | MPC | 110-120V 1~ 60Hz | R-1150 (A3, H220) | I / NFL | -100–40 |
| TC100-F | 58 | ON-OFF-Regler | 220-240V 1~/2~ 50/60Hz | R-1150 (A3, H220) | I / NFL | -100–40 |
| TC45 | — | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| TC45E | — | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| TC45E-F | 54 | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| TC45-F | 59 | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -45–100 |
| TC50 | — | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
| TC50E | — | MPC | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
| TC50-F | 60 | ON-OFF-Regler | 208-240V 1~/2~ 50/60Hz | R-290 (A3, H220) | I / NFL | -50–50 |
Full specifications
| Noise level | 60 dB(A) |
| Pump speed adjustable | no |
| Pump type | no pump |
| External sensor connection | Pt100 |
| Temperature range | -50...50 °C |
| Temperature stability mfr | ±0, 5 K |
| Alarm message mfr | optic, acoustic |
| Dimensions (W x D x H) mfr | 260 x 330 x 415 mm |
| Refrigeration machine mfr | air-cooled, natural refrigerant |
| Weight | 25 kg (net) |
| Current consumption | 3 A (max.) |
| Power supply | 208-240V 1~/2~ 50/60Hz |
| Controller | MPC |
| Temperature display | LED Display |
| Refrigerant | R-290 (A3, H220) (1st stage) |
| Refrigerant quantity 1st stage mfr | 0, 06 kg (1st stage) |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity mfr | 0, 2 kW (at -30 °C) |
| Safety class | I / NFL |
Description
Construction and series positioning
- Immersion cooler with a fixed 900 mm long, 13 mm diameter Pt100 probe on a 1150 mm flexible connection; no pump is fitted and pump speed is not adjustable.
- Air-cooled refrigeration machine using R-290 (A3, H220) natural refrigerant, 0.06 kg in the first stage; safety class I / NFL per DIN 12876.
- Cabinet 260 x 330 x 415 mm, 25 kg net. Within the series, the TC50E-F is the smaller-capacity unit: siblings TC100, TC100E and TC100E-F are rated 55 dB(A) versus 60 dB(A) here, and the CT50 Single OLÉ is 59 dB(A).
Thermal behavior
- Working range -50 to 50 °C, so the unit is for cooling only and cannot be used for heating above 50 °C.
- Cooling capacity is 0.3 kW at 0 °C, 0.26 kW at -20 °C and 0.2 kW at -30 °C, quoted at 20 °C room temperature; capacity falls as ambient rises, so the process heat load must be sized at the actual operating point with margin.
- Temperature stability is stated as ±0.5 K; control is by the MPC controller acting on a solenoid valve in the cooling circuit while the refrigeration unit runs continuously.
Installation, control and operation
- Supply is 208-240 V, single- or two-phase, 50/60 Hz, maximum current 3 A, with a 10-16 A fuse; single/two-phase units ship with a power cable and country-specific plug that must be specified at order.
- Voltage and frequency tolerances are coupled: ±5 % voltage only with ±2 % frequency, and opposite-sign deviations are not permitted.
- Ambient operating window is 5-40 °C; the air-cooled condenser requires the space clearances stated in the operating conditions.
- EMC classification is Class A, Group 1 to EN55011, intended for industrial environments; alarms are optical and acoustic, and the LED display shows temperature.
Integration & Operating Notes
The supply is 208-240 V single- or two-phase at 50/60 Hz with a maximum current of 3 A, but the datasheet requires circuit fusing no lower than 10 A and no higher than 16 A; a smaller protective device may trip on compressor inrush, and a larger one no longer protects the unit.
Voltage and frequency tolerances are coupled: ±5 % voltage is permitted only together with ±2 % frequency, and a -5 % voltage with +2 % frequency is explicitly not allowed. Verify the site supply against this rule before commissioning, since a supply inside each individual band can still violate the combined limit.
Cooling capacity is 0.3 kW at 0 °C, 0.26 kW at -20 °C and 0.2 kW at -30 °C, all valid at 20 °C room temperature. Capacity drops further as ambient rises, so the process load and pull-down time must be calculated at the lowest intended temperature and the actual room condition.
The working range is -50 to 50 °C. Processes that require heating above 50 °C, or that may exothermically exceed it, are outside the unit's capability and need a different circulator; the upper limit also bounds any bath or fluid the probe is immersed in.
The Pt100 probe is 13 mm in diameter and 900 mm long, connected by a 1150 mm flexible lead. The immersion depth and the distance from the bath or vessel to the unit must be checked against these dimensions before the mounting position is fixed.
Single- and two-phase devices from 100 V to 240 V are delivered with a power cable and a country-specific plug that must be stated at order. Confirm the plug type against the site socket before purchase, as it is not a universal accessory.
The unit is classified Class A, Group 1 to EN55011 and may cause radio interference in residential areas. Plan the installation for an industrial EMC environment, or add filtering if it must share a supply with sensitive electronics.
The first stage holds 0.06 kg of R-290 (A3, H220), a flammable natural refrigerant. Site approval, ventilation and avoidance of ignition sources in the vicinity must be addressed; the equipment is compliant with US-SNAP for industrial process refrigeration and with applicable EU laws.
The refrigeration unit runs continuously and the MPC controller regulates temperature through a solenoid valve in the cooling circuit. Service personnel should not interpret a non-cycling compressor as a control failure; alarms are indicated optically and acoustically on the unit.
Selection & Integration Q&A
Pick the TC50E-F when the load is at or below its 0.2 kW at -30 °C and 0.3 kW at 0 °C, and 60 dB(A) is acceptable. The TC100/TC100E/TC100E-F siblings run at 55 dB(A) and suit higher loads or quieter sites; the CT50 Single OLÉ sits at 59 dB(A).
208-240 V single- or two-phase, 50/60 Hz, max. 3 A, fused 10-16 A. Voltage and frequency deviations must not have opposite signs. The power cable and country-specific plug are supplied only if specified at order.
Ambient must stay within 5-40 °C with the datasheet space clearances around the air-cooled condenser. The 13 mm probe is 900 mm long on a 1150 mm flexible lead, so the vessel must be within that reach; Class A EMC means industrial locations only.
No pump is fitted, so circulation must come from the bath or an external loop. The country-specific plug must be ordered, and the Pt100 probe is fixed to the unit; no separate sensor, cable or mounting accessory is listed in the datasheet.