Agilent Technologies 1290 Infinity II Preparative LC System
Agilent Technologies 1290 Infinity II Preparative LC System — Liquid chromatography with Pumping speed 0.012 m³/h.
The 1290 Infinity II Preparative LC System is a preparative-scale HPLC platform configured for 1–3 inch id columns, distinguishing it from analytical-scale siblings in the series. It accommodates preparative column dimensions, bridging method development and scale-up purification.
Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection
Full specifications
| Pumping speed | 200 mL/min |
| Plate Count | 40606 Nth/meter |
| Retention Time | 15.18 min |
| Typical Flow Rate | 1 mL/min |
| Productivity range mfr | Grams Grams |
| Asymmetry mfr | 1.27 |
| Packing asymmetry mfr | 1.30 |
| Packing station air pressure mfr | 6 bar |
| SAC packing pressure (example) mfr | 666 psi |
| DAC packing pressure (example) mfr | 1015 psi |
| Sorbent particle size for DAC mfr | 8...15 μm |
| Sorbent particle size for SAC mfr | 10 larger |
| pressure at 50 mL/min mfr | 600 bar |
| pressure at 200 mL/min mfr | 420 bar |
| maximum flow rate (1260) mfr | 50 mL/min |
| sample capacity (Open-Bed) mfr | 864 samples |
| fraction capacity (Open-Bed) mfr | 432 fractions |
| maximum fraction capacity mfr | 1296 fractions |
| fractions per module (1260) mfr | 216 fractions |
| expandable fraction capacity (1260) mfr | 648 fractions |
| injection volume (1260 sampler) mfr | 3.6 mL |
| sample capacity (1260 sampler) mfr | 132 samples |
| sample loading increase (Load & Lock) mfr | 20 |
| Column Inner Diameter | 1...3 in |
| Column tube length used for slurry packing mfr | 60 less |
| maximum column inner diameter (1290) mfr | 50 mm |
| maximum column inner diameter (1260) mfr | 30 mm |
Description
Construction and positioning
- The 1290 Infinity II Preparative LC System is the preparative-scale member of Agilent's InfinityLab LC Purification Solutions portfolio, designed for columns with inner diameters from 1 to 3 inches (27 to 75 mm).
- It differs from analytical-scale siblings (1220, 1260 Analytical-Scale, 1260 Bio-Inert) by supporting larger-bore preparative columns, and from the 1260 Infinity II Manual Preparative LC System by its automated Infinity II architecture.
- The system integrates preparative modules such as column organizer, column compartment, manual injector, open-bed sampler/collector, detectors, fraction collectors, and optional LC/MSD XT, as described in the portfolio brochure.
Performance characteristics
- Verified performance data include a plate count of 40,606 N/m, retention time of 15.18 min, and asymmetry of 1.27, indicating efficient separation under the tested conditions.
- Typical flow rate is listed as 1 mL/min, which is representative of analytical-scale operation; for preparative columns (1–3 in id), flow rates would be scaled accordingly, but no specific preparative flow values are provided in the verified facts.
- The productivity range is given as "Micrograms" without a numeric value, so it is not further specified here.
Installation and operation
- The system is compatible with Agilent Load & Lock columns (1–3 in id) in both dynamic axial compression (DAC) and static axial compression (SAC) modes, with standard stainless steel water jackets and mobile packing stations for 1, 2, and 3 in id columns.
- No specific electrical, control, or environmental specifications are provided in the verified facts; refer to the instrument manuals for detailed installation requirements.
Integration & Operating Notes
Load & Lock columns in DAC or SAC modes require periodic packing and maintenance using the mobile packing stations available for 1, 2, and 3 in id columns. Follow the column manual for packing procedures and service intervals to maintain separation performance.
The system integrates with preparative modules such as column organizer, column compartment, manual injector, open-bed sampler/collector, detectors, fraction collectors, and LC/MSD XT. Ensure all modules are from the InfinityLab portfolio for compatibility.
Selection & Integration Q&A
Choose the 1290 Infinity II Preparative LC System when you need automated preparative purification with columns from 1 to 3 inches id and integration with InfinityLab modules. The 1260 Infinity II Manual Preparative LC System is for manual operation, while analytical-scale siblings (1220, 1260 Analytical-Scale) are limited to smaller columns and lower sample loads.
The system requires preparative columns with 1–3 inch inner diameters, such as Agilent Load & Lock columns in DAC or SAC mode with stainless steel water jackets. Peripheral modules (column organizer, fraction collector, detectors, LC/MSD XT) must be from the InfinityLab portfolio to ensure compatibility and proper control.
The verified facts do not specify mounting or environmental limits. Refer to the instrument's site preparation guide and user manual for bench space, power, and environmental requirements. The system is typically installed on a stable laboratory bench with adequate ventilation.
Regular maintenance includes column packing and replacement using mobile packing stations for 1, 2, and 3 in id columns. The base system does not include columns, packing stations, or fraction collectors; these must be ordered separately. Refer to the column manual for service intervals.