No photo available yet
Agilent Technologies 1220 Infinity II Analytical-Scale LC Purification System
Agilent Technologies 1220 Infinity II Analytical-Scale LC Purification System — Liquid chromatography.
The 1220 Infinity II Analytical-Scale LC Purification System is a preparative HPLC configuration built around a 4.6 mm inner-diameter column and a typical flow rate of 1 mL/min, targeting microgram-level productivity. Within the InfinityLab purification series it is the analytical-scale entry point, distinct from the 1260 and 1290 preparative systems that handle larger column formats and higher mass loads.
Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection
Full specifications
| Typical Flow Rate | 1 mL/min |
| Productivity range mfr | Micrograms Micrograms |
| Column Inner Diameter | 4.6 mm |
Description
Construction and series positioning
- The 1220 Infinity II Analytical-Scale LC Purification System is the analytical-scale member of Agilent's InfinityLab LC purification portfolio, which also includes 1260 Analytical-Scale, 1260 Bio-Inert Analytical-Scale, 1260 Infinity II Manual Preparative, and 1260 Infinity II Preparative (UV-based) systems.
- It is specified around a 4.6 mm column inner diameter with a typical flow rate of 1 mL/min, placing it in the analytical column format rather than the larger preparative formats of the 1260/1290 preparative siblings.
- Productivity range is stated in micrograms, consistent with analytical-scale purification rather than milligram-to-gram preparative recovery.
Behavior and media
- No digitized curve points or pressure/flow performance curves were supplied for this model, so no load-dependent or gradient behavior can be asserted beyond the stated typical flow rate and column format.
- The verified facts do not define solvent compatibility, pressure limits, or detector configuration for this specific model; these must be taken from the instrument's own specification sheet rather than inferred from sibling systems.
Installation, control and operation
- The attached portfolio brochure (5991-9154EN) covers the purification portfolio at a catalogue level and contains no actionable installation, connection, or control facts for this model; no electrical, interface, or environment specifications were verified.
- Because electrical ratings, control interfaces, and installation requirements are absent from the verified facts, they are intentionally not stated here.
Integration & Operating Notes
The system is specified with a 4.6 mm column inner diameter and a typical flow rate of 1 mL/min. Adjacent equipment — pumps, tubing, detector flow cells, and fraction collection — must be sized for this analytical-scale flow and column format; preparative-scale hardware from the 1260/1290 siblings is not interchangeable with this configuration.
The stated productivity range is micrograms. Purification targets requiring milligram or gram quantities fall outside this model's stated range and belong to the preparative siblings (1260 Infinity II Preparative LC System, 1260 Analytical-Scale Purification System) rather than this analytical-scale configuration.
No voltage, current, power, or control-interface specifications were verified for this model. Before specifying power distribution or connecting a controller/data system, obtain the instrument-specific specification sheet; do not carry over electrical data from other InfinityLab purification systems.
Selection & Integration Q&A
Choose this model when the purification target is in the microgram range on a 4.6 mm column at about 1 mL/min. For milligram-to-gram recovery, larger columns, or bio-inert flow paths, the 1260 Analytical-Scale, 1260 Bio-Inert, or 1260 Infinity II Preparative systems are the appropriate series members.
Plumb and size the pump, tubing, detector cell, and collection hardware for a 4.6 mm column and a typical 1 mL/min flow. Verified facts give no pressure rating or solvent compatibility for this model, so confirm those from the instrument specification sheet before selecting mating parts.
No environment, mounting, or duty-cycle limits were verified for this model; the attached portfolio brochure contains no installation data. Obtain the instrument's own manual for bench space, ambient conditions, and continuous-operation limits before site planning.
No maintenance intervals, consumables list, or included accessories were verified. The brochure covers the portfolio and preparative columns/supplies generally, not this model's delivery scope; confirm columns, tubing kits, and service parts against the instrument's order documentation.