Peter Huber Kältemaschinenbau CS 75 by Van der Heijden
Peter Huber Kältemaschinenbau CS 75 by Van der Heijden — Recirculating chillers with Noise level 66 dB.
The CS 75 is a 37-litre-bath recirculating chiller in the Cs series, operating from -20 to +15 °C on a 400 V three-phase supply. It is the smallest sibling, distinguished by a 70 l/min pump and G3/4 male connection. It serves low-temperature process cooling with a 50:50 water-glycol fluid.
Peter Huber Kältemaschinenbau Cs Chiller Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Minimum fill volume, m³ | Power supply | Pump connection | Temperature range, °C |
|---|---|---|---|---|---|---|
| CS 75 by Van der Heijden Current | 66 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 100 by Van der Heijden | 70 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 100-H by Van der Heijden | 71 | 5–32 | 0.175 | 400V 3~ 50Hz | G3/4 AG male | -20–85 |
| CS 200 by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–15 |
| CS 200-H by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–85 |
| CS 20-H by Van der Heijden | 57 | 5–32 | 0.024 | 230V 1~ 50Hz | G3/8 AG male | -20–85 |
| CS 25 by Van der Heijden | 60 | 5–32 | 0.024 | 230V 1~ 50Hz | G1/2 AG male | -20–15 |
| CS 50 by Van der Heijden | 63 | 5–32 | 0.1 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| Huber CS 200-H | 78 | 5–32 | 0.225 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 25 | 60 | 5–32 | 0.024 | 208V 2~ 60Hz | G1/2 AG male | -20–15 |
| Huber CS 250HT OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G3/4 AG male | 10–22 |
| Huber CS 330-H OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550-H OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550 OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–15 |
| Huber LCS 80 | 77 | -20–50 | 0.04 | 460V 3~ 60Hz | G1 AG male | -45–15 |
Full specifications
| Noise level | 66 dB(A) |
| Bath volume | 37 l |
| Maximum delivery flow rate | 70 l/min (3, 7 bar) |
| Minimum fill volume | 160 l |
| Pump connection | G3/4 AG male |
| Temperature range | -20...15 °C |
| Weight | 265 kg |
| Current consumption | 14 A |
| Power supply | 400V 3~ 50Hz |
| Digital interface | RS232 |
| Ambient temperature limit | 5...32 °C |
| Protection rating | IP52 |
| Safety class | I / NFL |
Description
Construction and series positioning
The CS 75 is an air-cooled recirculating chiller with a 37 l integrated bath and a minimum system fill of 160 l. Within the Cs series it is the smallest model; the CS 100, CS 100-H, CS 125 and CS 125-H are larger siblings with higher noise levels (70–75 dB(A) vs 66 dB(A) here). The unit uses refrigerant R-449A (A1, H280) with a CO2 equivalent of 6.29 t. The pump delivers up to 70 l/min through a G3/4 male connection, and flow can be trimmed via a manual bypass valve on the rear panel.
Operating envelope and media
- Temperature range: -20 to +15 °C.
- Ambient temperature limit: 5 to 32 °C.
- Recommended thermofluid: 50:50 water–monoethylene glycol.
- Cooling capacity is rated at 20 °C room temperature and may drop as ambient rises.
- Bath volume 37 l; minimum filling capacity 160 l.
Electrical and control
- Power supply: 400 V 3~ 50 Hz, 14 A current consumption, 3×20 A fuse.
- Protection rating IP52; safety class I / NFL.
- Interface: RS232.
- Delivered with cable but without plug for three-phase connection below 63 A.
- EN55011 Class A Group 1 disturbance classification.
Installation notes
Voltage and frequency tolerances must be respected simultaneously; combinations such as -5% voltage with +2% frequency are not allowed. Space requirements around the air-cooled condenser must be observed per the operating conditions.
Integration & Operating Notes
Voltage and frequency tolerances must be respected simultaneously. Some combinations, such as -5% voltage with +2% frequency, are explicitly not allowed. Verify the site supply or generator against the permissible envelope before connection to avoid operating outside the unit's design limits.
Output data are valid for a room temperature of 20 °C. If the ambient temperature rises, the cooling capacity may drop. Size the heat load and plant-room ventilation with this derating in mind, and keep the ambient within the 5–32 °C range.
The recommended thermofluid is a 50:50 water–monoethylene glycol mixture, which is necessary to reach the lower end of the -20 to +15 °C range without freezing. The system fill must be at least 160 l; the integrated bath holds 37 l.
Space requirements around the air-cooled unit must be observed per the operating conditions. The IP52 rating protects against dust and dripping water but not water jets or immersion, so washdown cleaning is not permitted. Ambient must stay between 5 and 32 °C.
The unit provides an RS232 interface for remote monitoring or control. Flow rate can be adjusted via the manual bypass valve on the back of the chiller to match pump delivery to the application, avoiding excessive flow or pressure in the external circuit.
Selection & Integration Q&A
Pick the CS 75 for the lowest noise (66 dB(A)) and smallest footprint in the series when the heat load fits its capacity. The CS 100/125 and -H variants offer more capacity but run at 70–75 dB(A); choose them only if the CS 75's cooling output is insufficient.
The external circuit must mate with a G3/4 male pump connection and accommodate up to 70 l/min. Electrically, provide a 400 V 3~ 50 Hz supply fused at 3×20 A with a site-fitted plug; the unit ships with cable but no plug. RS232 is available for control.
Operate only between 5 and 32 °C ambient, with condenser clearance per the operating conditions. IP52 allows dust and dripping water but not jets or immersion. Cooling capacity is rated at 20 °C room temperature and derates as ambient rises.
The unit is delivered with a power cable but without a plug, so a suitable three-phase plug must be sourced. The heat-transfer fluid is not included; prepare a 50:50 water–monoethylene glycol mixture and allow for a minimum system fill of 160 l.