Peter Huber Kältemaschinenbau Huber LCS 80
Peter Huber Kältemaschinenbau Huber LCS 80 — Recirculating chillers with Noise level 77 dB.
The Huber LCS 80 is a 460 V 3-phase 60 Hz recirculating chiller with a -45 to 15 °C operating range, 20 kW cooling at 15 °C falling to 8.5 kW at -40 °C, and a 53 l/min G1 pump. It is the low-temperature, high-capacity member of the Cs Chiller series, intended for process cooling where the duty point sits well below ambient.
Peter Huber Kältemaschinenbau Cs Chiller Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Minimum fill volume, m³ | Power supply | Pump connection | Temperature range, °C |
|---|---|---|---|---|---|---|
| Huber LCS 80 Current | 77 | -20–50 | 0.04 | 460V 3~ 60Hz | G1 AG male | -45–15 |
| CS 100 by Van der Heijden | 70 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 100-H by Van der Heijden | 71 | 5–32 | 0.175 | 400V 3~ 50Hz | G3/4 AG male | -20–85 |
| CS 200 by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–15 |
| CS 200-H by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–85 |
| CS 20-H by Van der Heijden | 57 | 5–32 | 0.024 | 230V 1~ 50Hz | G3/8 AG male | -20–85 |
| CS 25 by Van der Heijden | 60 | 5–32 | 0.024 | 230V 1~ 50Hz | G1/2 AG male | -20–15 |
| CS 50 by Van der Heijden | 63 | 5–32 | 0.1 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 75 by Van der Heijden | 66 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| Huber CS 200-H | 78 | 5–32 | 0.225 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 25 | 60 | 5–32 | 0.024 | 208V 2~ 60Hz | G1/2 AG male | -20–15 |
| Huber CS 250HT OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G3/4 AG male | 10–22 |
| Huber CS 330-H OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550-H OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550 OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–15 |
Full specifications
| Noise level | 77 dB(A) (sound pressure level) |
| Bath volume | 37 l |
| Maximum delivery flow rate | 53 l/min (max.; pressure 4, 7 bar) |
| Minimum fill volume | 40 l (min.) |
| Pump connection | G1 AG male |
| Temperature range | -45...15 °C |
| Weight | 880 kg (net) |
| Current consumption | 50 A (max.) |
| Power supply | 460V 3~ 60Hz |
| Digital interface | RS232 |
| Refrigerant | R-449A (A1, H280) (1st stage) |
| Refrigerant charge | 16 kg (1st stage) |
| Ambient temperature limit | -20...50 °C (permissible) |
| Safety class | I / NFL |
Description
Construction and series positioning
- The LCS 80 is a single-stage R-449A (A1, H280) chiller with a 16 kg refrigerant charge (22.35 t CO2 equivalent), a 37 l bath and a net weight of 880 kg in a 2015x1100x2000 mm envelope.
- Within the Cs Chiller series, the LCS 80 is the low-temperature, high-capacity unit: its -45...15 °C window and 20 kW peak cooling distinguish it from the sibling CS 100/CS 100-H/CS 125/CS 125-H models, which are quoted at 70–75 dB(A) and are not specified for this temperature range.
- The pump delivers up to 53 l/min at a maximum delivery pressure of 4.7 bar through a G1 AG male connection.
Behavior under load and media
- Cooling capacity is strongly temperature-dependent: 20 kW at 15 °C, 8.5 kW at -40 °C. Sizing must use the capacity at the actual operating point, not the nominal figure.
- Capacity is quoted at 20 °C, 35 °C and 40 °C ambient; above +35 °C ambient the cooling power is reduced, so the installation site's ambient temperature directly limits available cooling.
- The recommended heat transfer fluid is Temper -55, selected to match the -45 °C lower limit; the bath volume must be kept between 40 l minimum and 105 l maximum, with a warning at 75 l.
Installation, control and operation
- Electrical supply is 460 V 3~ 60 Hz with 50 A maximum current and 3x60 A fusing. Three-phase devices below 63 A are delivered with cable but without a plug, so the site connector must be provided by the customer.
- The operating panel is a remote control on a 20 m cable, so the control station must be planned within that cable length. An RS232 interface is provided.
- The unit is suitable for outdoor mounting down to -20 °C ambient (up to +50 °C), which requires weather protection planning. It is EMC Class A Group 1, intended for industrial environments.
Integration & Operating Notes
The unit tolerates ±5% voltage only with a simultaneous ±2% frequency tolerance; the combination of -5% voltage with +2% frequency is explicitly not allowed. Verify site power quality before commissioning, because out-of-tolerance supply can damage the compressor and void compliance.
Three-phase devices with current consumption less than 63 A are delivered with cable but without a plug. The LCS 80 draws 50 A max and requires 3x60 A fusing, so the customer must provide and fit the site connector and size the protection device accordingly.
The bath volume ranges from 40 l minimum to 105 l maximum, with a warning at 75 l. Operating outside these limits risks insufficient heat transfer or overflow; the fill volume must be checked against the external circuit volume at commissioning.
The recommended heat transfer fluid is Temper -55, selected to match the low-temperature duty down to -45 °C. A fluid with a higher freeze point will degrade or freeze at the lower end of the operating range.
The unit is suitable for outside mounting with a minimum environmental temperature of -20 °C and a maximum of +50 °C. Outdoor siting widens placement options but requires weather protection planning and verification of cooling capacity at the site ambient, since capacity is reduced above +35 °C.
The operating panel is supplied as a remote control connected via a 20 m cable, so the operator station must be located within that cable length. An RS232 interface is available for integration with a supervisory controller.
The pump connection is G1 AG male with a maximum delivery flow of 53 l/min and a maximum delivery pressure of 4.7 bar. Hoses, fittings and the external circuit must be rated for this pressure and match the G1 thread to avoid leaks or over-pressurisation.
The refrigerant is R-449A (A1, H280) with a 16 kg charge and 22.35 t CO2 equivalent. F-gas/CO2-equivalent record-keeping and qualified refrigerant handling obligations apply, including leak reporting.
Selection & Integration Q&A
Pick the LCS 80 when the process needs temperatures down to -45 °C and up to 20 kW cooling at 15 °C. The CS 100/CS 125 siblings are quoted only by noise level (70–75 dB(A)) and are not specified for this low-temperature window, so they suit less demanding duty points.
A 460 V 3-phase 60 Hz supply with 50 A max current and 3x60 A fusing. The unit is delivered with cable but without a plug (below 63 A), so the customer must provide the connector. Supply must stay within ±5% voltage and ±2% frequency; -5% voltage with +2% frequency is not allowed.
Yes, outdoor mounting is permitted down to -20 °C ambient and up to +50 °C. However, cooling capacity is reduced above +35 °C ambient, so the site ambient must be checked against the capacity tables, and weather protection should be planned.
Base delivery includes the unit with cable but no plug, a remote operating panel on a 20 m cable, and an RS232 interface. The site connector, external circuit hoses/fittings matching G1 male and 4.7 bar, and the Temper -55 heat transfer fluid must be sourced separately.