Peter Huber Kältemaschinenbau Unistat P425 Dynamisches
Peter Huber Kältemaschinenbau Unistat P425 Dynamisches — Temperature control units with Noise level 65 dB.
The Unistat P425 Dynamisches is a free-standing, air-cooled temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -40 to 250 °C with 2 kW heating. Its 97 l/min zero-head pump delivers 30 l/min at 2.5 bar, making it the high-pressure-drop variant within the Unistat series. It serves closed-loop tempering of reactors and process equipment requiring dynamic temperature changes.
Peter Huber Kältemaschinenbau Unistate Bis 45C Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Power supply | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat P425 Dynamisches Current | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Grande Fleur Dynamisches | — | — | — | — | — | — |
| Grande Fleur w Dynamisches | — | 0, 01 | 208-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | -40–200 |
| Grande Fleur w-eo Dynamisches | — | — | — | — | — | — |
| Petite Fleur-eo Dynamisches | 58 | 0, 01 K | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | Pressure pump, variable | -40–200 |
| Petite Fleur w Dynamisches | — | 0, 01 | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | Pressure pump, variable | -40–200 |
| Unistat 410w Dynamisches | 61 | 0, 01 K | 220-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | -45–250 |
| Unistat 425w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat 430w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P405w Dynamisches | — | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st | -45–250 |
| Unistat P425w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P430 Dynamisches | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P430w Dynamisches | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
Full specifications
| Noise level | 65 dB(A) |
| Control output | POKO ONE |
| Filling volume | 4 l |
| Heating capacity | 2 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -40...250 °C |
| Weight | 185 kg |
| Current consumption | 12 A |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing Unistat P425 with air cooling (no suffix), Pilot ONE controller, and POKO ONE control output.
- The 'P' designation in the model name indicates the variant for applications with high pressure drop, distinguishing it from the Grande Fleur Dynamisches siblings in the same series.
- Magnetically coupled stainless-steel pump with M30x1.5 male connections; pump speed is adjustable.
- 4 l filling volume, 185 kg weight, IP20 protection, safety class III / FL.
Thermal and hydraulic behavior
- Temperature range -40 to 250 °C; heating capacity 2 kW; display resolution 0.01 K.
- Pump curve: 97 l/min at zero head, 30 l/min at 2.5 bar — the external circuit pressure drop must be matched to this curve.
- Maximum permissible kinematic viscosity 50 mm²/s; heat transfer fluid must remain within this limit at low temperatures.
- Cooling capacity is rated at 20 °C room temperature and may drop at higher ambient temperatures.
Electrical and control
- 400 V 3~ 50 Hz supply, 12 A current consumption, 3x16 A fuse required.
- Interfaces: Ethernet, USB (Host and Device), RS232; external Pt100 sensor connection.
- Pilot ONE controller with touchscreen, LED flow diagram, and programmable temperature control programs.
- Process Safety mode available (requires compressor set to Permanently ON); Power Failure Auto can resume temperature control after outage.
Installation and operation
- Three-phase devices below 63 A are delivered with cable but without plug; a suitable plug must be provided on site.
- Leakage current exceeds 3.5 mA; additional protective measures such as a suitable RCD may be required.
- Ambient temperature range 5 to 40 °C; EMC Class A Group 1 for industrial environments.
- Refrigerant R-452A, 2.01 kg, GWP 2141, 4.3 t CO2 equivalent — F-gas reporting and leak-check obligations apply.
Integration & Operating Notes
The unit draws 12 A and requires a 3x16 A fuse; the electrical installation, cable, and protection device must be sized accordingly. Voltage tolerance is ±5% with simultaneous frequency tolerance ±2%, but certain combinations are not allowed, so supply quality must be checked before commissioning.
Leakage current exceeds 3.5 mA, which may require additional protective measures such as a suitable residual current device. The electrical safety design must account for this before energizing the unit.
For externally closed applications the expansion vessel must remain unlocked; locking it will damage the application due to overpressure. For externally open (bath) applications the expansion vessel must be locked to prevent fluid loss.
The maximum permissible kinematic viscosity is 50 mm²/s. The fluid must be selected so that it remains within this limit at the lowest operating temperature, otherwise pump overload and poor circulation will result.
The pump delivers 97 l/min at zero head but only 30 l/min at 2.5 bar. The external application's pressure drop must be evaluated against this curve to ensure adequate flow; the 'P' variant is intended for high pressure drop applications.
The allowable ambient temperature range is 5 to 40 °C. Cooling capacity is rated at 20 °C room temperature and may drop at higher ambient temperatures, so derating must be considered and adequate room ventilation provided.
When moving the unit between cold and warm environments, allow about 2 hours acclimation before turning it on to prevent condensation-induced electrical faults. Transport must be upright only; horizontal transport damages the compressor.
In Process Safety mode, when the overtemperature trigger value is reached the controller releases maximum cooling capacity instead of switching off all poles. This mode requires the compressor to be set to Permanently ON to keep cooling active.
If temperature control is active during a power outage, Power Failure Auto resumes the process automatically after power returns. Choose the power-interruption behavior according to whether unattended restart is acceptable for the process.
Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The unit uses 2.01 kg of R-452A (GWP 2141, 4.3 t CO2 equivalent), which triggers F-gas reporting and leak-check obligations.
Selection & Integration Q&A
Choose the P425 when the external circuit has a high pressure drop: its pump delivers 30 l/min at 2.5 bar (97 l/min at zero head). The Grande Fleur siblings are not specified for high pressure drop applications; select them only when the application's pressure drop is low and the P425's pressure capability is unnecessary.
Pump connections are M30x1.5 male with Y-bore (60°) per DIN 3863; use ball sockets per DIN 3863 and sleeve nuts per DIN 3870. The unit is delivered with cable but without a plug for the 400 V 3~ 50 Hz supply; provide a suitable plug and a 3x16 A fuse. Leakage current >3.5 mA may require an RCD.
Install only in non-ATEX areas with ambient temperature 5–40 °C. Transport upright only; allow 2 hours acclimation before power-on. Leveling feet must be activated and parking brakes engaged. For closed applications keep the expansion vessel unlocked; for open bath applications lock it. Cooling capacity derates above 20 °C room temperature.
Periodically check hoses and connections for leaks and replace as needed; clean liquefier fins and the hat-type strainer; inspect heat transfer fluid and replace per schedule. Shut off cooling water even overnight. A plug for the 400 V supply, mating DIN 3863/3870 fittings, heat transfer fluid, and a drip tray are not included and must be provided on site.