Peter Huber Kältemaschinenbau Unistat P425 Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat P425 Dynamisches

Peter Huber Kältemaschinenbau Unistat P425 Dynamisches — Temperature control units with Noise level 65 dB.

The Unistat P425 Dynamisches is a free-standing, air-cooled temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -40 to 250 °C with 2 kW heating. Its 97 l/min zero-head pump delivers 30 l/min at 2.5 bar, making it the high-pressure-drop variant within the Unistat series. It serves closed-loop tempering of reactors and process equipment requiring dynamic temperature changes.

Noise level
65 dB

Peter Huber Kältemaschinenbau Unistate Bis 45C Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionPower supplyPump connectionPump typeTemperature range, °C
Unistat P425 Dynamisches Current 650, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250
Grande Fleur Dynamisches ——————
Grande Fleur w Dynamisches —0, 01208-240V 1~/2~ 50/60HzM24x1, 5 AG malePressure pump, variable -40–200
Grande Fleur w-eo Dynamisches ——————
Petite Fleur-eo Dynamisches 580, 01 K220-240V 1~/2~ 50/60HzM16x1 AG malePressure pump, variable -40–200
Petite Fleur w Dynamisches —0, 01220-240V 1~/2~ 50/60HzM16x1 AG malePressure pump, variable -40–200
Unistat 410w Dynamisches 610, 01 K220-240V 1~/2~ 50/60HzM24x1, 5 AG malePressure pump, variable -45–250
Unistat 425w Dynamisches 610, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250
Unistat 430w Dynamisches 610, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250
Unistat P405w Dynamisches —0, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st-45–250
Unistat P425w Dynamisches 610, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250
Unistat P430 Dynamisches 650, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250
Unistat P430w Dynamisches 650, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250

Full specifications

Core Performance & Functional Specifications
Noise level 65 dB(A)
Control output POKO ONE
Filling volume 4 l
Heating capacity 2 kW
Pump connection M30x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -40...250 °C
Dimensions, Weight & Mechanical Design
Weight 185 kg
Electrical, Power & Drive Specifications
Current consumption 12 A
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Thermal and hydraulic behavior

Electrical and control

Installation and operation

Integration & Operating Notes

Electrical
Supply must be 400 V 3~ 50 Hz with 3x16 A fuse

The unit draws 12 A and requires a 3x16 A fuse; the electrical installation, cable, and protection device must be sized accordingly. Voltage tolerance is ±5% with simultaneous frequency tolerance ±2%, but certain combinations are not allowed, so supply quality must be checked before commissioning.

Datasheet, Technical Specifications; Instruction Manual, Section 1.8
Electrical
Leakage current >3.5 mA requires RCD evaluation

Leakage current exceeds 3.5 mA, which may require additional protective measures such as a suitable residual current device. The electrical safety design must account for this before energizing the unit.

Datasheet, Technical Specifications
Mounting
Expansion vessel must be unlocked for closed applications

For externally closed applications the expansion vessel must remain unlocked; locking it will damage the application due to overpressure. For externally open (bath) applications the expansion vessel must be locked to prevent fluid loss.

Instruction Manual, Section 2.2 Preparations for Operation
Process Limits
Heat transfer fluid viscosity must stay below 50 mm²/s

The maximum permissible kinematic viscosity is 50 mm²/s. The fluid must be selected so that it remains within this limit at the lowest operating temperature, otherwise pump overload and poor circulation will result.

Datasheet, Technical Specifications
Process Limits
External circuit pressure drop must match pump curve

The pump delivers 97 l/min at zero head but only 30 l/min at 2.5 bar. The external application's pressure drop must be evaluated against this curve to ensure adequate flow; the 'P' variant is intended for high pressure drop applications.

Datasheet, Technical Specifications
Mounting
Ambient temperature must remain between 5 and 40 °C

The allowable ambient temperature range is 5 to 40 °C. Cooling capacity is rated at 20 °C room temperature and may drop at higher ambient temperatures, so derating must be considered and adequate room ventilation provided.

Datasheet, Technical Specifications
Mounting
Allow 2 hours acclimation before first power-on

When moving the unit between cold and warm environments, allow about 2 hours acclimation before turning it on to prevent condensation-induced electrical faults. Transport must be upright only; horizontal transport damages the compressor.

Instruction Manual, Section 3 Commissioning
Control & I/O
Process Safety mode requires compressor set to Permanently ON

In Process Safety mode, when the overtemperature trigger value is reached the controller releases maximum cooling capacity instead of switching off all poles. This mode requires the compressor to be set to Permanently ON to keep cooling active.

Instruction Manual, Section 1.7.2 / Setup Mode
Control & I/O
Power Failure Auto can restart temperature control unattended

If temperature control is active during a power outage, Power Failure Auto resumes the process automatically after power returns. Choose the power-interruption behavior according to whether unattended restart is acceptable for the process.

Instruction Manual, Section 1.8.1
Maintenance
Refrigerant circuit work requires certified contractors

Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The unit uses 2.01 kg of R-452A (GWP 2141, 4.3 t CO2 equivalent), which triggers F-gas reporting and leak-check obligations.

Instruction Manual, Section 1.4.2; Datasheet

Selection & Integration Q&A

When should I choose the Unistat P425 Dynamisches instead of a Grande Fleur Dynamisches sibling?

Choose the P425 when the external circuit has a high pressure drop: its pump delivers 30 l/min at 2.5 bar (97 l/min at zero head). The Grande Fleur siblings are not specified for high pressure drop applications; select them only when the application's pressure drop is low and the P425's pressure capability is unnecessary.

What mating fittings and power supply components are required for the P425's external circuit and electrical connection?

Pump connections are M30x1.5 male with Y-bore (60°) per DIN 3863; use ball sockets per DIN 3863 and sleeve nuts per DIN 3870. The unit is delivered with cable but without a plug for the 400 V 3~ 50 Hz supply; provide a suitable plug and a 3x16 A fuse. Leakage current >3.5 mA may require an RCD.

What are the mounting and duty-cycle limits for the P425 according to the manual?

Install only in non-ATEX areas with ambient temperature 5–40 °C. Transport upright only; allow 2 hours acclimation before power-on. Leveling feet must be activated and parking brakes engaged. For closed applications keep the expansion vessel unlocked; for open bath applications lock it. Cooling capacity derates above 20 °C room temperature.

What maintenance schedule and accessories are required, and what is not included in the base delivery?

Periodically check hoses and connections for leaks and replace as needed; clean liquefier fins and the hat-type strainer; inspect heat transfer fluid and replace per schedule. Shut off cooling water even overnight. A plug for the 400 V supply, mating DIN 3863/3870 fittings, heat transfer fluid, and a drip tray are not included and must be provided on site.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat P425 Temperature Control System Datasheet
Datasheet ·105,7 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF