Peter Huber Kältemaschinenbau CC-108A
Peter Huber Kältemaschinenbau CC-108A — Thermostatic baths.
The CC-108A is a 6-litre polycarbonate-bath immersion circulator with a variable-speed pressure/suction pump and Pilot ONE controller, rated 25–100 °C without cooling, 20–100 °C with water cooling and 15–100 °C with a refrigerator. It sits between the CC-106A and CC-110A in bath volume within the series. It serves as a temperature-control source for external circuits and open baths up to 100 °C.
Direct drop-in replacements
Peter Huber Kältemaschinenbau Mit Polycarbonatbaedern Bis 100C Series — Model Comparison & Selection
| Model | Controller | Interface | Max delivery flow rate, liter/minute | Pump connection | Weight, kg | Ambient temperature limit, °C |
|---|---|---|---|---|---|---|
| CC-108A Current | Pilot ONE | Ethernet, USB (Host u. D | 27 | M16x1 AG male (Option, # | 6 | 5–40 |
| CC-104A | Pilot ONE | Ethernet, USB (Host u. D | 22 | M16x1 AG male | 6 | 5–40 |
| CC-106A | Pilot ONE | Ethernet, USB (Host u. D | 22 | M16x1 AG male | 5 | 5–40 |
| CC-110A | Pilot ONE | Ethernet, USB (Host u. D | 22 | M16x1 AG male | 6 | 5–40 |
| CC-112A | Pilot ONE | Ethernet, USB (Host u. D | 27 | M16x1 AG male (Option, # | 8 | 5–40 |
| CC-118A | Pilot ONE | Ethernet, USB (Host u. D | 22 | M16x1 AG male (Option, # | 8 | 5–40 |
| KISS 104A | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male | 5 | 5–40 |
| KISS 106A | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male (Option, # | 5 | 5–40 |
| KISS 108A | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male (Option, # | 6 | 5–40 |
| KISS 110A | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male (Option, # | 6 | 5–40 |
| KISS 112A | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male (Option, # | 8 | 5–40 |
| KISS 118A | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male (Option, # | 8 | 5–40 |
Full specifications
| Bath volume | 6 l |
| Filling volume | 4 l (min.) |
| Maximum delivery flow rate | 27 l/min (pressure pump; also 0, 7 bar) suction pump; also 0, 4 bar: 22 l/min |
| Pump connection | M16x1 AG male (Option, #19606) (Option, #19606) |
| Pump speed adjustable | Yes |
| Pump type | Pressure and suction pump, variable speed |
| External sensor connection | Pt100 |
| Temperature range | 25...100 °C with cooling unit: 15...100 °C · with water cooling: 20...100 °C |
| Temperature stability mfr | ±0, 02 K |
| Dimensions (W x D x H) mfr | 147 x 407 x 330 mm |
| Heating capacity mfr | 1, 5 - 2, 1 kW |
| Bath opening WxD/BD mfr | 130 x 210 / 150 |
| Weight | 6 kg |
| Current consumption | 10 A (max.) |
| Power supply | 200-240V 1~/2~ 50/60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Transparent polycarbonate bath, 6 l working volume, minimum filling 4 l, bath opening 130 x 210 mm with 150 mm depth; overall 147 x 407 x 330 mm, 6 kg.
- Immersion circulator architecture with Pilot ONE controller, Pt100 external sensor input, and a variable-speed pressure and suction pump.
- Within the CC-10xA series, the CC-108A is the 6-litre step; the CC-104A, CC-106A, CC-110A and CC-112A bracket it at smaller and larger bath volumes. Choose this size when the external circuit plus bath inventory fits 4–6 l.
Thermal behaviour and media
- Temperature range is cooling-method dependent: 25–100 °C uncooled, 20–100 °C with water cooling, 15–100 °C with a refrigerator. The polycarbonate bath caps operation at 100 °C.
- Temperature stability is stated as ±0.02 K; heating capacity 1.5–2.1 kW.
- Pump delivers up to 27 l/min at 0.7 bar pressure side and 22 l/min at 0.4 bar suction side, with adjustable speed.
- Polyglycol must not be used as heat-transfer fluid when a Huber pump adapter is fitted.
Installation, control and operation
- Powered from 200–240 V, 1~ or 2~, 50/60 Hz, max. 10 A; external branch protection to UL 489 required, fuse 10–16 A. Country-specific plug must be specified at order.
- Interfaces: Ethernet, USB host and device, RS232; external Pt100 sensor connection; adjustable overtemperature protection to DIN 12876.
- IP20, ambient 5–40 °C; Class A Group 1 to EN55011, so EMC measures may be needed in sensitive environments.
Integration & Operating Notes
The 200–240 V 1~/2~ supply draws up to 10 A; the manufacturer requires external branch circuit protection according to UL 489 and a fuse between 10 A and 16 A. Undersized protection will trip at run-up, oversized protection leaves the unit unprotected.
A ±10 % voltage tolerance is permitted only if the frequency deviation does not run in the opposite direction; a −10 % voltage combined with +3 % frequency is not allowed. Verify site power quality before commissioning, otherwise output data are not guaranteed.
The transparent polycarbonate bath is limited to a maximum of 100 °C; exceeding it risks deformation and loss of containment. The adjustable overtemperature protection to DIN 12876 must be set below this limit for the bath and external circuit.
With a 6 l bath volume and 4 l minimum filling capacity, the bath must not be run below 4 l; low level risks pump cavitation and poor temperature control. Account for the volume held in external tubing and the circuit when filling.
Without cooling the unit operates 25–100 °C; water cooling extends the low end to 20 °C and a refrigerator to 15 °C. Specify the cooling method before sizing the external circuit, since the achievable setpoint changes with it.
When a Huber pump adapter is used, polyglycol is not permissible as heat-transfer fluid; using it can damage the pump circuit or create a safety hazard. Select an alternative fluid compatible with polycarbonate and the external loop.
Degree of protection IP20 offers no water protection, so the installation location must be dry and within 5–40 °C ambient. Respect the manufacturer's space requirements for ventilation and access before siting the unit.
Single- and two-phase devices are delivered with a power cable and a country-specific plug; the plug type must be specified when ordering to avoid a mismatch with the site socket and a rework delay.
The unit is classified Class A, Group 1 to EN55011; in residential or EMC-sensitive surroundings additional filtering or shielding may be required. Plan this before installing near sensitive analytical instrumentation.
Selection & Integration Q&A
Pick the CC-108A when the bath inventory plus external circuit fits its 6 l volume (4 l minimum fill) and the 130 x 210 mm opening suits the workload. Step to the CC-106A for smaller baths or the CC-110A when more volume is needed; all share the same 100 °C polycarbonate limit.
A 200–240 V 1~/2~ 50/60 Hz supply with UL 489 branch protection and a 10–16 A fuse, plus a country-specific plug specified at order. The external loop must tolerate up to 27 l/min at 0.7 bar pressure side and 22 l/min at 0.4 bar suction side.
Install dry, at 5–40 °C ambient, respecting the manufacturer's space requirements; IP20 gives no water protection. Keep the bath at or above 4 l fill and at or below 100 °C, with overtemperature protection to DIN 12876 set accordingly.
The country-specific plug must be specified at order; the M16x1 male pump connection is an option (#19606), not standard. No cooling unit is included unless ordered, so the 15–20 °C range requires a refrigerator or water cooling to be added.