Peter Huber Kältemaschinenbau KISS 110A
Peter Huber Kältemaschinenbau KISS 110A — Thermostatic baths.
The KISS 110A is a 7.5-litre polycarbonate-bath immersion circulator with a fixed-speed pressure/suction pump and 1.5–2.1 kW heater, covering 25–100 °C without cooling, 20–100 °C with water cooling, or 15–100 °C with a refrigerator. Its Safety Class III/FL and ±0.05 K stability distinguish it within the KISS series for precise, fail-safe temperature control of external circuits and bath-mounted samples.
Direct drop-in replacements
Peter Huber Kältemaschinenbau Mit Polycarbonatbaedern Bis 100C Series — Model Comparison & Selection
| Model | Controller | Interface | Max delivery flow rate, liter/minute | Pump connection | Weight, kg | Ambient temperature limit, °C |
|---|---|---|---|---|---|---|
| KISS 110A Current | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male (Option, # | 6 | 5–40 |
| CC-104A | Pilot ONE | Ethernet, USB (Host u. D | 22 | M16x1 AG male | 6 | 5–40 |
| CC-106A | Pilot ONE | Ethernet, USB (Host u. D | 22 | M16x1 AG male | 5 | 5–40 |
| CC-108A | Pilot ONE | Ethernet, USB (Host u. D | 27 | M16x1 AG male (Option, # | 6 | 5–40 |
| CC-110A | Pilot ONE | Ethernet, USB (Host u. D | 22 | M16x1 AG male | 6 | 5–40 |
| CC-112A | Pilot ONE | Ethernet, USB (Host u. D | 27 | M16x1 AG male (Option, # | 8 | 5–40 |
| CC-118A | Pilot ONE | Ethernet, USB (Host u. D | 22 | M16x1 AG male (Option, # | 8 | 5–40 |
| KISS 104A | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male | 5 | 5–40 |
| KISS 106A | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male (Option, # | 5 | 5–40 |
| KISS 108A | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male (Option, # | 6 | 5–40 |
| KISS 112A | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male (Option, # | 8 | 5–40 |
| KISS 118A | KISS | USB (Device), RS232 Inte | 14 | M16x1 AG male (Option, # | 8 | 5–40 |
Full specifications
| Alarm output | optic, acoustic |
| Dimensions (w × D × H) | 147 x 507 x 330 mm |
| Maximum delivery flow rate | 14 l/min (pressure pump; 0, 25 bar) |
| Pump connection | M16x1 AG male (Option, #19606) (Option, #19606) |
| Pump speed adjustable | no |
| Pump type | Pressure and suction pump, speed not variable |
| Temperature range | 25...100 °C with cooling unit: 15...100 °C · with water cooling: 20...100 °C |
| Temperature stability mfr | ±0, 05 K |
| Heating capacity mfr | 1, 5 - 2, 1 kW |
| Delivery capacity suction pump max. mfr | 10, 5 l/min (suction pump; 0, 17 bar) |
| Bath opening WxD/BD mfr | 130 x 310 / 150 mm (WxD/depth) |
| Bath volume mfr | 7, 5 l |
| Filling volume min. mfr | 4, 4 l (minimum) |
| Weight | 6 kg |
| Current consumption | 10 A (max.) |
| Power supply | 200-240V 1~/2~ 50/60Hz V; Hz |
| Controller | KISS |
| Digital interface | USB (Device), RS232 Interface |
| Temperature display | OLED Display |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Immersion circulator with a 7.5 l polycarbonate bath (minimum fill 4.4 l) and a 130 × 310 mm opening, 150 mm deep.
- Fixed-speed pressure and suction pump: 14 l/min at 0.25 bar pressure side, 10.5 l/min at 0.17 bar suction side.
- KISS controller with OLED display; USB (Device) and RS232 interfaces; optical and acoustic alarm output.
- Safety Class III/FL with adjustable overtemperature protection per DIN 12876, suitable for flammable bath fluids.
- Sibling models CC-104A through CC-110A share the series but differ in configuration; the KISS 110A is the 7.5 l variant with the stated pump and heater ratings.
Thermal behaviour and media
- Temperature range is cooling-dependent: 25–100 °C without cooling, 20–100 °C with water cooling, 15–100 °C with a refrigerator.
- Heating power scales with supply voltage: 1.5 kW at 200 V, 1.6 kW at 208 V, 1.8 kW at 220 V, 2.0 kW at 230 V, 2.1 kW at 240 V.
- Temperature stability is ±0.05 K.
- The plastic pump is not resistant to acetone or polyglycols; for freeze protection, water should be mixed with glysantine or ethylene glycol.
Installation, connection and control
- Supply: 200–240 V, 1~ or 2~, 50/60 Hz; maximum current 10 A; branch-circuit fusing 10–16 A; external branch circuit protection per UL 489 required.
- Country-specific plug must be specified at ordering; voltage and frequency tolerances of ±10% are permitted only if they do not act in opposite directions.
- IP20 rating requires a dry location; ambient temperature must remain 5–40 °C.
- Optional Pt100 sensor connection (#10688) is for display only, not control, and is factory-fitted.
- Optional M16×1 AG male pump connection (#19606).
Integration & Operating Notes
The unit draws up to 10 A on a 200–240 V single/two-phase supply. Install external branch circuit protection according to UL 489 and size fusing between 10 A and 16 A; undersizing risks nuisance trips, oversizing risks inadequate fault clearing.
Without cooling the bath cannot go below 25 °C; water cooling extends the range to 20 °C, and a refrigerator to 15 °C. Select the cooling utility before specifying setpoints below 25 °C, and provide the corresponding water or refrigerant circuit.
The plastic pump is not resistant to acetone or polyglycols (depending on manufacturer). For freeze protection near or below ambient, mix water with glysantine or ethylene glycol rather than using pure water, which can freeze and damage the circuit.
IP20 protection means the unit must be kept dry and protected from water ingress. Ambient temperature at the installation site must stay between 5 °C and 40 °C to avoid derating or damage; condensation and splashing must be prevented.
The factory-fitted Pt100 sensor connection (#10688) only displays process temperature and cannot be used to control the bath. Do not specify it expecting external-sensor closed-loop control; use the internal KISS controller for setpoint regulation.
Single/two-phase devices are supplied with a power cable and a country-specific plug that must be stated when ordering. Voltage and frequency tolerances of ±10% are permitted only if they do not act in opposite directions.
Selection & Integration Q&A
Choose the KISS 110A when you need a 7.5 l bath with 25–100 °C range (15–100 °C with refrigerator) and the fixed-speed pressure/suction pump. Siblings differ in configuration; confirm bath volume and cooling option against your sample load before selecting.
Provide 200–240 V, 1~ or 2~, 50/60 Hz with a country-specific plug specified at ordering. Maximum current is 10 A; install branch-circuit fusing of 10–16 A and external UL 489 protection. Voltage/frequency tolerance ±10% only if not opposing.
The base unit does not include the optional Pt100 sensor connection (#10688, factory-fitted) or the M16×1 AG male pump connection (#19606). A country-specific plug must be specified at ordering. No maintenance schedule is given in the datasheet; follow the manual for service intervals.