Peter Huber Kältemaschinenbau Unimotive 10w-XT
Peter Huber Kältemaschinenbau Unimotive 10w-XT — Temperature control units.
The Unimotive 10w-XT is a water-cooled temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -45 to 150 °C for water-ethylene glycol mixtures. Its 12 kW heating and 14 kW cooling at 20 °C distinguish it within the Unimotive series, while cooling capacity falls to 0.8 kW at -40 °C. It serves automotive test benches and process circuits requiring sub-zero temperature control.
Peter Huber Kältemaschinenbau Unimotive Series — Model Comparison & Selection
| Model | Display resolution | Heating capacity, W | Power supply | Pump connection | Refrigerant | Safety class |
|---|---|---|---|---|---|---|
| Unimotive 10w-XT Current | 0, 01 | 12000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | I / NFL |
| Unimotive 10w | 0.01 | 12000 | 400V 3~ 50Hz | M38x1,5 AG male | R-452A (A1, H280) | III / FL |
| Unimotive 20w | 0, 01 | 12000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | III / FL |
| Unimotive 20w-XT | 0, 01 | 12000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | I / NFL |
| Unimotive 26w | 0, 01 K | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | III / FL |
| Unimotive 26w-XT | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | I / NFL |
| Unimotive 27w | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | III / FL |
| Unimotive GL 07w | 0, 01 | 12000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 07w-XT | 0, 01 | 12000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | I / NFL |
| Unimotive GL 10w | 0, 01 | 24000 | 460V 3~ 60Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 10w-XT | 0, 01 | 24000 | 460V 3~ 60Hz | M38x1, 5 AG male | R-744 (A1, H280) | I / NFL |
| Unimotive GL 20w | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 20w-XT | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | I / NFL |
| Unimotive GL 30w | 0, 01 | 24000 | 460V 3~ 60Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 50w | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 50w-XT | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | I / NFL |
| Unimotive GL 60w | 0, 01 | 48000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 60w-XT | 0, 01 | 48000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | I / NFL |
Full specifications
| Control output | POKO ONE |
| Heating capacity | 12 kW |
| Pump connection | M38x1, 5 AG male |
| Pump speed adjustable | no |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -45...150 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Refrigerant | R-452A (A1, H280) (1st stage) |
| Maximum viscosity | 200 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water consumption | 620 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 1 bar (min.) |
| Cooling Water Pressure | 6 bar (max.) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- The Unimotive 10w-XT is a water-cooled unit using R-452A refrigerant in the first stage, with a magnetically coupled stainless-steel pump and a Pilot ONE controller with POKO ONE control output.
- It is positioned among Unimotive siblings (10w, 20w, 20w-XT, 26w) as the XT variant of the 10w platform, adding extended low-temperature capability down to -45 °C for water-ethylene glycol mixtures with corrosion protection.
- The unit is designed for water-ethylene glycol mixtures with corrosion protection (e.g., Glysantin®) down to -45 °C; the heat transfer fluid must match this chemistry.
Behavior under load and media
- Cooling capacity is strongly temperature-dependent: 14 kW at 20 °C, dropping to 0.8 kW at -40 °C, so process heat loads at low temperature must be checked against this reduced capacity.
- The pump delivers a maximum of 201 l/min, but flow falls with pressure (e.g., 42 l/min at 5.0 bar); the external circuit pressure drop must be matched to the application.
- Maximum permissible kinematic viscosity of the heat transfer fluid is 200 mm²/s to prevent pump overload or poor circulation at low temperature.
- The unit operates within an ambient temperature range of 5 °C to 40 °C.
Installation, connection and control
- Cooling water must be supplied between 5 °C and 20 °C with a differential pressure between 1 bar and 4 bar and a maximum supply pressure of 6 bar; pipes must be insulated if water temperature can drop below the condensation point.
- The unit requires a 400 V three-phase 50 Hz supply and is delivered without a plug for three-phase devices below 63 A; voltage and frequency tolerances are ±5% and ±2% respectively, but the combination of -5% voltage with +2% frequency is not allowed.
- Leakage current exceeds 3.5 mA, affecting protective earthing and RCD selection.
- The unit is classified as EN 55011 Class A Group 1, which has implications for use in residential environments.
- Interfaces include Ethernet, USB (Host and Device), and RS232; an external Pt100 sensor can be connected.
Integration & Operating Notes
The maximum permissible kinematic viscosity of the heat transfer fluid is 200 mm²/s. Exceeding this can cause pump overload or poor circulation, especially at low temperatures.
Cooling capacity falls significantly at low temperatures, from 14 kW at 20 °C to 0.8 kW at -40 °C. Verify that the process heat load at the lowest operating temperature does not exceed this reduced capacity.
The unit must not be installed or started inside an ATEX zone, so hazardous-area installations are excluded. Additionally, observe the refrigerant charge (2.9 kg R-452A, 6.2 t CO2 equivalent) and room size to avoid dangerous refrigerant concentration.
The unit requires a 400 V three-phase 50 Hz supply and is delivered with cable but without a plug for three-phase devices below 63 A. The electrician must provide a suitable plug/connection on site. Replacement power cables are length-limited to 4 m for 3-phase connections.
Selection & Integration Q&A
Choose the 10w-XT when you need -45 °C capability with water-ethylene glycol and moderate heating/cooling capacity (12 kW heating, 14 kW cooling at 20 °C). The 10w lacks the extended low-temperature range; the 20w-XT offers higher capacity but may be oversized for smaller loads.
Provide cooling water at 5–20 °C with a differential pressure of 1–4 bar and maximum supply pressure of 6 bar. Use G3/4 male connections, install a backflow preventer on the building side, and ensure only drinking water or filtered river/sea water (no sea water) is used.
Operate within an ambient temperature of 5–40 °C. Do not install in an ATEX zone. Ensure minimum wall clearances per the manual, install a drip tray, and shut off cooling water during downtimes. The unit is EN 55011 Class A Group 1, suitable for industrial EMC environments.
The base delivery excludes a plug for three-phase devices below 63 A; the electrician must provide a suitable plug/connection. A drip tray and backflow preventer are site responsibilities. Regular maintenance includes checking cooling water quality and refrigerant charge; no specific service intervals are listed in the provided digests.