Peter Huber Kältemaschinenbau Unimotive 27w
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unimotive 27w

Peter Huber Kältemaschinenbau Unimotive 27w — Temperature control units.

The Unimotive 27w is a water-cooled circulating temperature control unit with a magnetically coupled stainless-steel pump, covering -45 to 95 °C with 24 kW heating capacity. It is the largest of the Unimotive w-series, distinguished by its 35 kW cooling power at 20 °C and 57 A three-phase draw. It serves automotive test benches circulating water-glycol mixtures through external loads.

Peter Huber Kältemaschinenbau Unimotive Series — Model Comparison & Selection

Model Display resolutionHeating capacity, WPower supplyPump connectionRefrigerantSafety class
Unimotive 27w Current 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive 10w 0.0112000400V 3~ 50HzM38x1,5 AG maleR-452A (A1, H280)III / FL
Unimotive 10w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 20w 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive 20w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 26w 0, 01 K24000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive 26w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive GL 07w 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 07w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 10w 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 10w-XT 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 20w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 20w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 30w 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 50w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 50w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 60w 0, 0148000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 60w-XT 0, 0148000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Heating capacity 24 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable no
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -45...95 °C
Dimensions, Weight & Mechanical Design
Weight 456 kg
Electrical, Power & Drive Specifications
Current consumption 57 A (max.)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Refrigerant R-452A (A1, H280) (1st stage)
Maximum viscosity 200 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water consumption 1530 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 1 bar (min.)
Cooling Water Pressure 6 bar (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Thermal behavior and media

Control, connection and operation

Integration & Operating Notes

Electrical
Leakage current above 3.5 mA constrains RCD selection

The unit's leakage current exceeds 3.5 mA, so standard 30 mA residual current devices may nuisance-trip. Earthing and protective-device coordination must be planned by the installing electrician, and the supply must be a socket with protective earth or a hardwired connection made by a certified electrician.

Datasheet, Technical Specifications; Operation Manual, Section Electrical Connection
Electrical
Voltage and frequency tolerances cannot be combined freely

Supply tolerances are ±5% voltage and ±2% frequency, but the combination of -5% voltage with +2% frequency is explicitly not allowed. Verify the actual site supply against this rule before commissioning, since a marginal grid condition can otherwise put the unit outside its permitted operating envelope.

Datasheet, Technical Specifications
Cooling & Media
Cooling water must stay within 5–20 °C and 1–4 bar differential

The unit is designed for cooling water intake between 5 °C and 20 °C, with a minimum differential pressure of 1 bar and maximum pressure of 6 bar. Only drinking water or filtered river/sea water is permitted; sea water is prohibited. Pipes must be insulated where surface temperature falls below the condensation point.

Datasheet, Technical Specifications; Operation Manual, Section Cooling Water Connection
Cooling & Media
Shut off cooling water during downtimes, even overnight

Cooling water can flow through the unit even when it is switched off, so the supply must be shut off for shorter downtimes such as overnight. A backflow preventer on the building side is mandatory to protect the drinking water supply, and outdoor siting requires frost-protected lines with cooling water never below 5 °C.

Operation Manual, Section Cooling Water Connection
Mounting
Drip tray and wall clearances are mandatory site provisions

The responsible body must install a condensation water / heat transfer fluid drip tray below the unit. Minimum wall clearances depend on whether the unit is air- or water-cooled and on whether it runs with or without a bath; these clearances govern energy dissipation and must be respected to avoid overheating.

Operation Manual, Sections Installation and Setup
Mounting
ATEX zones and EMC-sensitive areas are excluded

The unit must not be installed or started inside an ATEX zone. It is a Group 1 Class A device per EN55011, intended for industrial EMC environments, so it may not be EMC-compatible in residential or light-industrial settings. Refrigerant charge and room size must be checked during installation to avoid dangerous refrigerant concentration.

Operation Manual, Sections Foreword and Installation
Process Limits
Pressure-sensitive loads need bypass evaluation

For pressure-sensitive applications such as glass reactors, the maximum flow pressure of the unit must be taken into account and an external bypass may be required. Hose inside diameters must at least match the M38x1.5 pump connections, with larger diameters for longer lines to limit pressure drop.

Operation Manual, Section Normal Operation
Process Limits
Bring fluid to room temperature before switching off

The heat transfer fluid must always be adjusted to room temperature before switching off to avoid overpressure in the system. This applies at the end of every test cycle and before maintenance or draining, and protects both the unit and the connected application from pressure damage.

Operation Manual, Section Normal Operation

Selection & Integration Q&A

When should I choose the Unimotive 27w rather than a 10w or 20w sibling?

Pick the 27w when the load needs up to 24 kW heating and high cooling power at moderate temperatures (35 kW at 20 °C), accepting 57 A three-phase draw and 456 kg. The 10w and 20w cover lower capacities; the -XT variants are separate modifications, not substitutes for this frame.

What must the facility provide for cooling water and power to integrate this unit?

Cooling water at 5–20 °C, 1–4 bar differential (max 6 bar), G3/4 male connections, 1530 l/h at 15 °C intake, with a building-side backflow preventer. Power is 400 V 3~ 50 Hz, 57 A max, 3x63 A fusing; cable supplied without plug, and leakage current above 3.5 mA affects RCD choice.

Where can the unit be installed and what site provisions are mandatory?

Indoors in a dry area, 5–40 °C ambient, IP20, never in an ATEX zone; it is Group 1 Class A EMC equipment for industrial environments. A drip tray below the unit is mandatory, wall clearances per the manual apply, and refrigerant charge versus room size must be checked.

What is not included in base delivery and what maintenance-related items must be planned?

The three-phase cable is supplied without a plug, so a suitable plug or hardwired connection by a certified electrician is needed. Mating pump fittings (ball socket per DIN 3863, sleeve nut per DIN 3870) and the drip tray are not part of the unit. Cooling water must be shut off during downtimes.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unimotive 27w
Datasheet ·84,5 КБ ·2 pp.
View PDF
PDF
Unimotive Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF