Peter Huber Kältemaschinenbau Unimotive 20w-XT
Peter Huber Kältemaschinenbau Unimotive 20w-XT — Temperature control units.
The Unimotive 20w-XT is a water-cooled temperature control unit with a 12 kW heater and a magnetically coupled stainless steel pump, covering -45 to 150 °C. It is the extended-temperature variant of the 20w series, distinguished by its low-temperature capability and 35 A three-phase supply. It serves automotive thermal simulation and material testing with water-ethylene glycol mixtures.
Peter Huber Kältemaschinenbau Unimotive Series — Model Comparison & Selection
| Model | Display resolution | Heating capacity, W | Power supply | Pump connection | Refrigerant | Safety class |
|---|---|---|---|---|---|---|
| Unimotive 20w-XT Current | 0, 01 | 12000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | I / NFL |
| Unimotive 10w | 0.01 | 12000 | 400V 3~ 50Hz | M38x1,5 AG male | R-452A (A1, H280) | III / FL |
| Unimotive 10w-XT | 0, 01 | 12000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | I / NFL |
| Unimotive 20w | 0, 01 | 12000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | III / FL |
| Unimotive 26w | 0, 01 K | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | III / FL |
| Unimotive 26w-XT | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | I / NFL |
| Unimotive 27w | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-452A (A1, H280) | III / FL |
| Unimotive GL 07w | 0, 01 | 12000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 07w-XT | 0, 01 | 12000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | I / NFL |
| Unimotive GL 10w | 0, 01 | 24000 | 460V 3~ 60Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 10w-XT | 0, 01 | 24000 | 460V 3~ 60Hz | M38x1, 5 AG male | R-744 (A1, H280) | I / NFL |
| Unimotive GL 20w | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 20w-XT | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | I / NFL |
| Unimotive GL 30w | 0, 01 | 24000 | 460V 3~ 60Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 50w | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 50w-XT | 0, 01 | 24000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | I / NFL |
| Unimotive GL 60w | 0, 01 | 48000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | III / FL |
| Unimotive GL 60w-XT | 0, 01 | 48000 | 400V 3~ 50Hz | M38x1, 5 AG male | R-744 (A1, H280) | I / NFL |
Full specifications
| Control output | POKO ONE |
| Heating capacity | 12 kW |
| Pump connection | M38x1, 5 AG male |
| Pump speed adjustable | no |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -45...150 °C |
| Weight | 466 kg |
| Current consumption | 35 A (max) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Refrigerant | R-452A (A1, H280) (1st stage) |
| Maximum viscosity | 200 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water consumption | 920 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
The Unimotive 20w-XT is a water-cooled temperature control unit built for operation with water-ethylene glycol mixtures (with corrosion protection) down to -45 °C. Within the Unimotive series, the 20w-XT is the extended-temperature modification of the 20w platform; sibling models 10w, 10w-XT, 20w and 26w differ in capacity and temperature envelope. The unit uses a magnetically coupled stainless steel pump with fixed speed (not adjustable) and a Pilot ONE controller with POKO ONE control output. The refrigerant is R-452A (A1, H280) in the first stage. The pump connection is M38x1.5 AG male, and the cooling water connection is G3/4 male.
Performance and load behavior
Heating capacity is 12 kW. Cooling capacity is strongly temperature-dependent: 21 kW at 20 °C falling to 3 kW at -40 °C, so low-temperature duty must be sized against the actual operating point. Quoted capacities are valid only at 20 °C room temperature, 15 °C cooling water inlet and 1 bar differential pressure between cooling water inlet and outlet. The pump delivers 201 l/min at zero head but only 42 l/min at 5 bar, so external circuit pressure drop directly limits achievable flow. The maximum permissible kinematic viscosity of the heat transfer fluid is 200 mm²/s, which constrains fluid selection at low temperatures.
Installation, connection and control
Electrical supply is 400 V three-phase 50 Hz with a maximum current of 35 A and 3x40 A fusing. Three-phase devices below 63 A are delivered with a cable but without a plug. Leakage current exceeds 3.5 mA, affecting RCD selection. Voltage tolerance is ±5% with simultaneous frequency tolerance of ±2%. The unit is IP20 and EMC Class A Group 1 (EN55011), intended for industrial environments. Cooling water must be between 5 °C and 20 °C intake, with differential pressure between 1 bar and 4 bar and maximum supply pressure 6 bar; a backflow preventer on the building side is required. The unit needs at least 8.2 l filling capacity and has a 19.9 l expansion tank. Interfaces include Ethernet, USB (Host and Device) and RS232; an external Pt100 sensor can be connected. The display resolution is 0.01 K.
Integration & Operating Notes
The unit's leakage current exceeds 3.5 mA, so residual current device selection and protective earthing must be engineered accordingly; a standard 30 mA RCD may not be suitable without considering this higher leakage.
The unit is delivered with a cable but no plug because its current consumption is below 63 A; the site must provide a suitable three-phase connection with protective earth, and hardwiring must be done by a certified electrician.
The cooling water supply must be between 5 °C and 20 °C, with a differential pressure between 1 bar and 4 bar and a maximum supply pressure of 6 bar; only drinking water or filtered river/sea water may be used, and sea water is prohibited.
Cooling water can flow even when the unit is switched off, so the supply should be shut off during downtimes (e.g. overnight) to prevent water damage and unnecessary consumption; a backflow preventer on the building side is mandatory.
A condensation water / heat transfer fluid drip tray must be installed below the unit by the responsible body, and minimum wall clearances depend on air- or water-cooling and on whether the unit runs with or without a bath; these must be respected to avoid overheating.
The maximum permissible kinematic viscosity of the heat transfer fluid is 200 mm²/s, which limits how cold or viscous the fluid may be; the unit is designed for water-ethylene glycol mixtures with corrosion protection down to -45 °C.
The Pilot ONE controller supports an external Pt100 sensor connection and provides Ethernet, USB (Host and Device) and RS232 interfaces for integration into monitoring or automation systems; display resolution is 0.01 K.
Selection & Integration Q&A
Choose the 20w-XT when you need the -45 °C low-temperature capability of the XT variant combined with the 20 kW-class cooling capacity of the 20w platform. The 20w without XT has a narrower temperature range, while the 10w-XT offers lower capacity; the 26w provides higher capacity but may exceed your space or utility limits.
The cooling water intake must be 5–20 °C with a differential pressure of 1–4 bar and maximum supply pressure of 6 bar. Use only drinking water or filtered river/sea water (no sea water). A backflow preventer on the building side is mandatory, and pipes must be insulated if the water temperature can drop below the dew point.
The unit is rated IP20 and must operate between 5 °C and 40 °C ambient in a clean, temperature-controlled indoor location. It must not be installed in an ATEX zone. Minimum wall clearances depend on cooling type and bath configuration, and a drip tray must be installed below the unit.
The base delivery includes a power cable but no plug for three-phase connections below 63 A. A drip tray and backflow preventer are site-provided. The unit requires water-ethylene glycol mixture with corrosion protection; regular maintenance includes checking refrigerant charge and room size, and shutting off cooling water during downtimes.