Agilent Technologies 1260 Infinity Bio-Inert Analytical-Scale LC Purification System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1260 Infinity Bio-Inert Analytical-Scale LC Purification System

Agilent Technologies 1260 Infinity Bio-Inert Analytical-Scale LC Purification System — Liquid chromatography.

The 1260 Infinity Bio-Inert Analytical-Scale LC Purification System is a bio-inert, analytical-scale purification platform configured for columns of 1–3 in inner diameter. It is distinguished within the 1260 Infinity II series by its bio-inert flow path, making it suitable for biomolecule purification where metal interaction must be avoided. The system is used for fraction collection and compound isolation at typical analytical flow rates around 1 mL/min.

Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection

Model Column inner diameter, mmTypical flow rate, mL/minPlate count, Nth/meterRetention time, minCarryover, %Sample capacity
1260 Infinity Bio-Inert Analytical-Scale LC Purification System Current 1...314060615.18——
1220 Infinity II Analytical-Scale LC Purification System 4.61————
1260 Analytical-Scale Purification System | Preparative HPLC 1...314060615.18——
1260 Infinity II Manual Preparative LC System 1...314060615.18——
1260 Infinity II Preparative LC System | UV based Prep HPLC 1...314060615.185132
1260 Prime Bio Analytical-Scale Purification System 4.61——9×10⁻⁴6144
1290 Analytical-Scale LC Purification 1...314060615.18——
1290 Infinity Autoscale Preparative system 1...314060615.18——
1290 Infinity III 4.61——9×10⁻⁴6144
1290 Infinity II Preparative LC System 1...314060615.18——
Automated LC/MSD purification| High-precision| Complex mixtures 1...314060615.18——
Flexible HPLC/UHPLC, Prime Analytical-Scale Purification System 1...314060615.18——
High-throughput Purification | Drug discovery | Biological 1...314060615.18——
Preparative LC/MSD System | Enhanced Purification & Efficiency 1...314060615.18——

Full specifications

Core Performance & Functional Specifications
Plate Count 40606 Nth/meter
Retention Time 15.18 min
Typical Flow Rate 1 mL/min
Productivity range mfr Micrograms Micrograms
Asymmetry mfr 1.27
Dimensions, Weight & Mechanical Design
Column Inner Diameter 1...3 in

Description

Construction and positioning

Behavior and performance

Installation and operation

Integration & Operating Notes

Maintenance
Bio-inert flow path requires compatible solvents

The bio-inert construction is designed to minimize metal interaction, but using solvents that degrade the inert materials (e.g., strong acids or bases at high concentrations) can compromise the flow path and lead to contamination. Always verify solvent compatibility with the bio-inert components before use.

InfinityLab LC Purification Solutions brochure 5991-9154EN
Mounting
Column packing station is a separate accessory

Mobile packing stations for 1, 2, and 3 inch ID columns are available but are not part of the base system delivery. If column packing is required, the appropriate packing station must be ordered separately and its footprint and utilities accounted for in the lab layout.

Load & Lock Columns brochure 5994-3907EN

Selection & Integration Q&A

When should I choose the 1260 Infinity Bio-Inert Analytical-Scale LC Purification System over the standard 1260 Analytical-Scale Purification System or the 1220 Infinity II system?

Choose the Bio-Inert version when purifying biomolecules or metal-sensitive compounds, as its flow path minimizes metal interaction. The standard 1260 lacks this inertness. The 1220 Infinity II is a lower-pressure system for simpler purifications and smaller columns; select it only if bio-inertness and higher pressure capability are not required.

What are the requirements for connecting a Load & Lock column to this system?

The system supports Load & Lock columns with 1–3 in ID. Ensure the column's compression mode (DAC or SAC) and water jacket connections are compatible with the system's plumbing. Use appropriate fittings for the column's inlet/outlet, and verify that the system's pressure rating meets the column's operating pressure. Packing stations are separate accessories.

What are the environmental and duty-cycle limits for operating this system?

The verified facts do not specify environmental limits or duty cycle. Refer to the instrument's site preparation guide for ambient temperature, humidity, and power requirements. As a general practice, avoid corrosive atmospheres and ensure adequate ventilation. Continuous operation at typical analytical flow rates (around 1 mL/min) is expected, but confirm with Agilent specifications.

What maintenance is required, and what accessories are not included in the base delivery?

Maintenance intervals are not detailed in the verified facts; follow the system's user manual for routine maintenance such as seal washes and lamp replacement. The base system does not include column packing stations, fraction collectors, or detectors unless explicitly ordered. Load & Lock columns and packing stations are separate accessories.