Agilent Technologies 1260 Infinity Bio-Inert Analytical-Scale LC Purification System
Agilent Technologies 1260 Infinity Bio-Inert Analytical-Scale LC Purification System — Liquid chromatography.
The 1260 Infinity Bio-Inert Analytical-Scale LC Purification System is a bio-inert, analytical-scale purification platform configured for columns of 1–3 in inner diameter. It is distinguished within the 1260 Infinity II series by its bio-inert flow path, making it suitable for biomolecule purification where metal interaction must be avoided. The system is used for fraction collection and compound isolation at typical analytical flow rates around 1 mL/min.
Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection
Full specifications
| Plate Count | 40606 Nth/meter |
| Retention Time | 15.18 min |
| Typical Flow Rate | 1 mL/min |
| Productivity range mfr | Micrograms Micrograms |
| Asymmetry mfr | 1.27 |
| Column Inner Diameter | 1...3 in |
Description
Construction and positioning
- The system is part of the Agilent InfinityLab LC Purification Solutions portfolio, specifically the 1260 Infinity II Analytical-Scale LC Purification Systems line.
- It is a bio-inert variant, meaning wetted materials are chosen to minimize metal contact, unlike the standard 1260 Analytical-Scale Purification System.
- Sibling models include the 1220 Infinity II Analytical-Scale LC Purification System (lower-pressure, simpler), the 1260 Infinity II Manual Preparative LC System (manual injection, preparative scale), and the 1260 Infinity II Preparative LC System (UV-based prep HPLC).
- This model is positioned for analytical-scale purification with column inner diameters from 1 to 3 inches (27–75 mm), bridging analytical and preparative scales.
Behavior and performance
- Verified performance data include a plate count of 40,606 N/m, retention time of 15.18 min, and typical flow rate of 1 mL/min, indicating analytical-scale operation.
- Asymmetry is 1.27, suggesting acceptable peak shape for purification.
- The productivity range is listed in micrograms, consistent with analytical-scale injections rather than preparative loads.
- No digitized curve points were provided; therefore, no gradient or pressure profiles are described.
Installation and operation
- The system is compatible with Agilent Load & Lock columns (1–3 in ID) available in dynamic axial compression (DAC) and static axial compression (SAC) modes, with standard stainless steel water jackets.
- Mobile packing stations exist for 1, 2, and 3 in ID columns, but these are separate accessories not included in the base system.
- The brochure digest lists preparative modules (column organizer, column compartment, manual injector, open-bed sampler/collector, detectors, fraction collectors, LC/MSD XT) as part of the portfolio, but it is not verified which of these are included in this exact model's standard delivery.
- No specific electrical, control, or environmental specifications were provided in the verified facts; therefore, integration details are limited to general compatibility.
Integration & Operating Notes
The bio-inert construction is designed to minimize metal interaction, but using solvents that degrade the inert materials (e.g., strong acids or bases at high concentrations) can compromise the flow path and lead to contamination. Always verify solvent compatibility with the bio-inert components before use.
Mobile packing stations for 1, 2, and 3 inch ID columns are available but are not part of the base system delivery. If column packing is required, the appropriate packing station must be ordered separately and its footprint and utilities accounted for in the lab layout.
Selection & Integration Q&A
Choose the Bio-Inert version when purifying biomolecules or metal-sensitive compounds, as its flow path minimizes metal interaction. The standard 1260 lacks this inertness. The 1220 Infinity II is a lower-pressure system for simpler purifications and smaller columns; select it only if bio-inertness and higher pressure capability are not required.
The system supports Load & Lock columns with 1–3 in ID. Ensure the column's compression mode (DAC or SAC) and water jacket connections are compatible with the system's plumbing. Use appropriate fittings for the column's inlet/outlet, and verify that the system's pressure rating meets the column's operating pressure. Packing stations are separate accessories.
The verified facts do not specify environmental limits or duty cycle. Refer to the instrument's site preparation guide for ambient temperature, humidity, and power requirements. As a general practice, avoid corrosive atmospheres and ensure adequate ventilation. Continuous operation at typical analytical flow rates (around 1 mL/min) is expected, but confirm with Agilent specifications.
Maintenance intervals are not detailed in the verified facts; follow the system's user manual for routine maintenance such as seal washes and lamp replacement. The base system does not include column packing stations, fraction collectors, or detectors unless explicitly ordered. Load & Lock columns and packing stations are separate accessories.