Peter Huber Kältemaschinenbau Unimotive 10w
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unimotive 10w

Peter Huber Kältemaschinenbau Unimotive 10w — Temperature control units.

Water-cooled Unimotive 10w immersion circulator with magnetically coupled stainless-steel pressure pump, covering -45 to 95 °C with 12 kW heating and 14 kW cooling at 20 °C. It is the base 10-size modification of the Unimotive series, distinguished by its water-cooled refrigeration circuit and 400 V three-phase supply. Intended for temperature control of water-glycol circuits in automotive test stands and similar industrial processes.

Peter Huber Kältemaschinenbau Unimotive Series — Model Comparison & Selection

Model Display resolutionHeating capacity, WPower supplyPump connectionRefrigerantSafety class
Unimotive 10w Current 0.0112000400V 3~ 50HzM38x1,5 AG maleR-452A (A1, H280)III / FL
Unimotive 10w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 20w 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive 20w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 26w 0, 01 K24000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive 26w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 27w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive GL 07w 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 07w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 10w 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 10w-XT 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 20w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 20w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 30w 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 50w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 50w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 60w 0, 0148000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 60w-XT 0, 0148000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Expansion volume 19.9 l
Filling volume 8.2 l (min)
Heating capacity 12 kW
Pump connection M38x1,5 AG male
Pump speed adjustable no
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -45...95 °C
Temperature stability 0.05 K
Alarm message mfr optic, acoustic, relay
Dimensions (W x D x H) mfr 730 x 804 x 1738 mm
Refrigeration machine mfr water-cooled, CFC- and HCFC-free
Delivery capacity pressure pump max. mfr 201 l/min; 5,3 bar
Pump characteristics mfr Pressure pump, speed not variable, magnetically
Control input mfr ECS ONE
Dimensions, Weight & Mechanical Design
Weight 440 kg
Electrical, Power & Drive Specifications
Current consumption 31.5 A (max)
Power supply 400V 3~ 50Hz
Fuse mfr 3x32A
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0.01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Refrigerant R-452A (A1, H280) (1st stage)
Refrigerant quantity 2.9 kg (1st stage)
Maximum viscosity 200 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water consumption 620 l/h (cooling water 15°C, flow 0°C)
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Cooling capacity mfr 20°C:14 kW; 0°C:10 kW; -20°C:5 kW; -30°C:2,1 kW; (at °C flow temperature)
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Working range and load behavior

Installation, connection and control

Integration & Operating Notes

Mounting
Install a drip tray and respect wall clearances and room volume

The responsible body must install a condensation water / heat transfer fluid drip tray below the unit. Minimum wall clearances depend on the cooling type and whether the unit runs with or without a bath. Refrigerant charge (2.9 kg R-452A) and room size must be checked to avoid dangerous refrigerant concentration. Installation inside an ATEX zone is prohibited.

Operation Manual, Sections Installation and Commissioning

Selection & Integration Q&A

When should I choose the Unimotive 10w rather than a sibling such as the 10w-XT or 20w?

Pick the 10w when the required cooling load fits its curve (14 kW at 20 °C down to 0.8 kW at -40 °C) and a water-cooled 10-size unit is sufficient. The 10w-XT and 20w/20w-XT/26w offer different sizes or configurations; select them only when their documented capacity or configuration is needed, as ratings are not interchangeable.

What cooling water and piping provisions must be in place before connecting the 10w?

Provide cooling water at 5–20 °C with 1–4 bar differential pressure and max 6 bar static pressure, using G3/4 male connections. Consumption is 620 l/h at 15 °C water and 0 °C flow. Install a building-side backflow preventer, use only drinking or filtered river water (no sea water), and insulate lines where condensation can occur.

What are the site and duty-cycle limits for installing the Unimotive 10w?

Ambient temperature must stay 5–40 °C; installation in an ATEX zone is prohibited. A drip tray is required below the unit, and wall clearances depend on cooling type and bath configuration. Check refrigerant charge (2.9 kg R-452A) against room volume. Shut off cooling water during downtimes, and bring fluid to room temperature before switch-off.

What is not included in base delivery and what maintenance/accessories must be planned?

The unit ships with a power cable but without a plug for the 400 V three-phase connection; a suitable plug and 3x32 A fusing must be provided on site. Pump hoses with M38x1.5 fittings and cooling water hoses with G3/4 fittings are not included. A drip tray and backflow preventer are site responsibilities. Regular maintenance per the manual includes cooling water circuit checks.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unimotive 10w Immersion Circulator
Datasheet ·84,5 КБ ·2 pp.
View PDF
PDF
Unimotive Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF