Peter Huber Kältemaschinenbau Unimotive GL 07w-XT
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unimotive GL 07w-XT

Peter Huber Kältemaschinenbau Unimotive GL 07w-XT — Temperature control units.

Water-cooled temperature control unit with magnetically coupled stainless-steel pump and 12 kW heating, covering -45 to 150 °C for externally closed circuits. The XT modification of the GL 07w is rated for water-ethylene glycol mixtures with corrosion protection down to -45 °C, distinguishing it from plain-water siblings. It serves automotive test benches and externally closed process loops requiring three-phase 400 V supply and site cooling water.

Peter Huber Kältemaschinenbau Unimotive Series — Model Comparison & Selection

Model Display resolutionHeating capacity, WPower supplyPump connectionRefrigerantSafety class
Unimotive GL 07w-XT Current 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive 10w 0.0112000400V 3~ 50HzM38x1,5 AG maleR-452A (A1, H280)III / FL
Unimotive 10w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 20w 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive 20w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 26w 0, 01 K24000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive 26w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 27w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive GL 07w 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 10w 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 10w-XT 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 20w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 20w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 30w 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 50w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 50w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 60w 0, 0148000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 60w-XT 0, 0148000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE (potential-free contact)
Heating capacity 12 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable no
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -45...150 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Refrigerant R-744 (A1, H280) (1st stage)
Maximum viscosity 200 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Behavior and media constraints

Installation, connection and control

Integration & Operating Notes

Electrical
Three-phase 400 V supply is mandatory; plug not included

The unit requires 400 V 3~ 50 Hz and cannot run on a single-phase supply. Three-phase devices below 63 A are delivered with cable but without a plug, so the customer must provide and fit the appropriate plug; hardwiring must be done by a certified electrician.

Unimotive GL 07w-XT Technical Data, page 2; Unimotive Operation Manual, page 31
Electrical
Leakage current >3.5 mA affects RCD and PE design

Protective earth and residual current protective device selection must account for a leakage current exceeding 3.5 mA. Always connect to a power socket with protective earth (PE).

Unimotive GL 07w-XT Technical Data, page 2; Unimotive Operation Manual, page 31
Cooling & Media
Only drinking water or filtered river water; sea water prohibited

Cooling water must be compatible with copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM. Sea water must not be used. A building-side backflow preventer is required to protect the drinking water supply.

Unimotive Operation Manual, page 28
Cooling & Media
Insulate internal cooling water pipes below condensation point

When cooling water temperatures fall below the condensation point, the cooling water pipes inside the unit must be insulated to prevent condensation and corrosion. Outdoor installation also requires frost-protected lines and a minimum cooling water temperature of 5 °C.

Unimotive GL 07w-XT Technical Data, page 2; Unimotive Operation Manual, page 28
Mounting
Install a drip tray below the unit before commissioning

The responsible body must install a condensation water / heat transfer fluid drip tray below the temperature control unit. Minimum wall clearances depend on air- or water-cooling and on whether the unit runs with or without a bath.

Unimotive Operation Manual, page 15 and page 25
Mounting
ATEX-zone installation is excluded

The unit must not be installed or started inside an ATEX zone. Refrigerant charge (R-744, H280) and room size must be checked during installation to avoid dangerous refrigerant concentration.

Unimotive Operation Manual, page 13 and page 15
Process Limits
Externally closed circuits only; viscosity limited to 200 mm²/s

The unit is intended for externally closed applications, not open baths. The circulating fluid's kinematic viscosity must not exceed 200 mm²/s, which constrains fluid choice at low temperatures. Pressure-sensitive loads such as glass reactors must account for the unit's maximum flow pressure, possibly with an external bypass.

Unimotive GL 07w-XT Technical Data, page 1; Unimotive Operation Manual, page 34
Electrical
Voltage and frequency tolerances are coupled

Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%; certain combinations such as -5% voltage with +2% frequency are not allowed. Verify supply quality at the installation site against this envelope.

Unimotive GL 07w-XT Technical Data, page 2

Selection & Integration Q&A

When should I choose the GL 07w-XT rather than a sibling such as the 10w-XT or 20w-XT?

Pick the GL 07w-XT when the process needs -45...150 °C with 12 kW heating and a water-ethylene glycol mixture with corrosion protection down to -45 °C in an externally closed circuit. Larger siblings 10w-XT/20w-XT apply when higher capacity is required; the non-XT 10w/20w variants are not specified for the glycol mixture.

What must the site provide for power and cooling water before this unit can be commissioned?

A 400 V 3~ 50 Hz supply with protective earth (plug not included; cable supplied for <63 A), leakage current >3.5 mA accounted for in RCD design, and cooling water at 1–4 bar differential and ≤6 bar static, compatible with copper/1.4401/EPDM, with a building-side backflow preventer.

What mounting and environment limits apply from the manual?

Ambient 5...40 °C, IP20, EMC Class A Group 1 (may interfere in residential areas), no ATEX zone, refrigerant charge vs room size checked, drip tray below the unit, wall clearances per the manual table, and frost-protected cooling water lines ≥5 °C for outdoor siting.

What is not included in base delivery and what service actions does the manual require?

The three-phase plug is not included (cable is supplied below 63 A); the customer provides the plug and the building-side backflow preventer and drip tray. Replacement power cables are limited to 3 m (1–2 phase) or 4 m (3-phase). Shut off cooling water during downtimes and warm the fluid to room temperature before switch-off.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unimotive GL 07w-XT Technical Data
Datasheet ·96,7 КБ ·2 pp.
View PDF
PDF
Unimotive Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF