Peter Huber Kältemaschinenbau Unistat T305 HT Dynamisches
Peter Huber Kältemaschinenbau Unistat T305 HT Dynamisches — Temperature control units.
The Unistat T305 HT Dynamisches is a high-temperature pressure temperature control unit with a variable-speed pump and Pilot ONE controller, covering 65–300 °C. It is the HT modification of the T305 series, distinguished by its high-temperature range and dynamic pressure pump. It serves closed-loop tempering of exothermic or high-temperature processes where sub-ambient cooling is not required.
Peter Huber Kältemaschinenbau Unistate Bis 425C Series — Model Comparison & Selection
| Model | Display resolution | Power supply | Pump connection | Pump type | Temperature range, °C | Expansion volume, m³ |
|---|---|---|---|---|---|---|
| Unistat T305 HT Dynamisches Current | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Chili Dynamisches | 0.01 | 200-240V 1~/2~ 50/60Hz | M24x1,5 AG male | Pressure pump, variable | 65–300 | 0.002 |
| Unistat T305 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305w HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T320 Dynamisches | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T320w HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330w HT Dynamisches | 0, 01 K | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T340 Dynamisches | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T340 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T350 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T402 Dynamisches | 0, 01 | 400V 3~N 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 80–425 | — |
| Unistat TR401 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 50–400 | 0.005 |
| Unistat TR402 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 80–425 | — |
Full specifications
| Control output | POKO ONE |
| Maximum delivery flow rate | 45 l/min (0, 9 bar) |
| Pump connection | M24x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | Pressure pump, variable speed |
| External sensor connection | Pt100 |
| Temperature range | 65...300 °C |
| Weight | 42 kg |
| Power supply | 200-240V 1~/2~ 50/60Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
The Unistat T305 HT Dynamisches is a high-temperature variant within the Unistat T305 series. Unlike the standard T305 Dynamisches or the T305w HT Dynamisches, this model is configured for a 65–300 °C operating window and uses a variable-speed pressure pump (Pilot ONE controller, POKO ONE control output). It is not intended for sub-ambient work; the Chili Dynamisches and T320 Dynamisches siblings cover different temperature ranges. The unit weighs 42 kg and is rated IP20 for dry indoor installation.
Behavior under load and media
Cooling capacity is strongly temperature-dependent: 3.2 kW at 300 °C falling to 0.6 kW at 100 °C, so heat-removal sizing must use the actual process temperature. The pump delivers up to 45 l/min at 0.9 bar; external loop pressure drop must be checked against this curve. The maximum permissible kinematic viscosity is 50 mm²/s, so the thermofluid must be selected to stay below this limit at the lowest operating temperature. Minimum filling capacity is 3.5 l and the expansion tank holds 4.5 l; the expansion vessel must be unlocked for externally closed applications and locked for open-bath use.
Installation, control and operation
Electrical supply is 200–240 V, 1~ or 2~, 50/60 Hz, with a maximum current just under 16 A at 230 V; the unit can be limited to 13 A or 10 A at first start-up. External branch circuit protection to UL 489 is required, and hard-wired connection must be performed by an electrician. The pump connection is M24x1.5 male with Y-bore to DIN 3863; hoses must use ball sockets to DIN 3863 and sleeve nuts to DIN 3870. The Pilot ONE controller provides Ethernet, USB (host and device) and RS232 interfaces, with 0.01 K display resolution and Pt100 external sensor input. Process Safety mode requires the compressor set to Permanently ON; Power Failure Auto resumes control after an outage if it was active. The unit is classified III / FL to DIN 12876 and pressure equipment category Art. 4.3 PED.
Integration & Operating Notes
Horizontal transport damages the compressor, and moving a filled unit risks thermal fluid overflow. Plan rigging and floor layout so the unit stays upright from delivery to commissioning, and empty the fluid circuit before any relocation.
External branch circuit protection according to UL 489 is mandatory ahead of the unit. Single- and two-phase units are delivered with a country-specific plug only if specified at order, so the purchase order must state the plug type to avoid site rework.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage. For externally open applications it must be locked to prevent fluid loss. Confirm the application type before commissioning and set the vessel accordingly.
When Process Safety mode is enabled, the compressor must be configured to Permanently ON so that cooling remains active at the over-temperature trigger. Verify this setting in the Pilot ONE controller before relying on the safety function.
The cooling water supply should be shut off even for short downtimes such as overnight to prevent water damage and unnecessary load on the cooling water circuit. Include this step in the daily shutdown procedure.
Hoses and hose connections must be checked periodically for leaks and quality and replaced as required. Establish a preventive maintenance interval based on duty cycle and fluid compatibility to avoid sudden failure in high-temperature service.
The IP20 rating excludes washdown and outdoor siting. Ambient temperature must stay between 5 and 40 °C, so room HVAC and placement away from heat sources must be considered. Allow about 2 hours acclimation when moving between cold and warm environments before power-on.
Selection & Integration Q&A
Choose the T305 HT Dynamisches for closed-loop processes requiring 65–300 °C with a variable-speed pressure pump. The standard T305 Dynamisches covers a different temperature range; the T305w HT is a water-cooled variant. Select the HT only when sub-ambient cooling is not needed.
The pump connection is M24x1.5 male with Y-bore to DIN 3863. Use flexible tempering hoses with ball sockets to DIN 3863 and sleeve nuts to DIN 3870. Non-matching fittings will not seal, so verify the standard before procuring hoses.
Install indoors in a dry location (IP20) with ambient 5–40 °C. Transport and store upright only; drain before moving. Allow 2 h acclimation after temperature changes. Do not install in an ATEX zone. Leveling feet or parking brakes must be engaged before operation.
The base delivery does not include hoses, fittings, or a country-specific plug unless specified at order. Periodically inspect hoses and connections for leaks and replace as needed. Shut off cooling water during downtimes. External UL 489 branch protection must be provided by the installer.