Peter Huber Kältemaschinenbau Unistat T402 Dynamisches
Peter Huber Kältemaschinenbau Unistat T402 Dynamisches — Temperature control units.
The Unistat T402 Dynamisches is a pressure-pump temperature control unit with a variable-speed pump, 6 kW heating, and a working range of 80 to 425 °C, positioned above the T305 siblings in the Unistat series. It requires a 400 V three-phase supply at up to 17 A and is intended for closed-loop heating of external circuits with high-temperature heat transfer fluids.
Peter Huber Kältemaschinenbau Unistate Bis 425C Series — Model Comparison & Selection
| Model | Display resolution | Power supply | Pump connection | Pump type | Temperature range, °C | Expansion volume, m³ |
|---|---|---|---|---|---|---|
| Unistat T402 Dynamisches Current | 0, 01 | 400V 3~N 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 80–425 | — |
| Chili Dynamisches | 0.01 | 200-240V 1~/2~ 50/60Hz | M24x1,5 AG male | Pressure pump, variable | 65–300 | 0.002 |
| Unistat T305 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305 HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305w HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T320 Dynamisches | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T320w HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330w HT Dynamisches | 0, 01 K | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T340 Dynamisches | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T340 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T350 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat TR401 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 50–400 | 0.005 |
| Unistat TR402 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 80–425 | — |
Full specifications
| Control output | POKO ONE (potential-free contact) |
| Heating capacity | 6 kW |
| Pump connection | M24x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | Pressure pump, variable speed |
| External sensor connection | Pt100 |
| Temperature range | 80...425 °C |
| Weight | 62 kg (net) |
| Current consumption | 17 A (max) |
| Power supply | 400V 3~N 50/60Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C (permissible) |
| Cooling water connection | G1/2 male |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- The T402 Dynamisches is a high-temperature variant of the Unistat series, distinguished from the T305 and T305 HT siblings by its 80–425 °C range and 6 kW heating capacity.
- It uses a variable-speed pressure pump with an M24x1.5 male connection, a Pilot ONE controller, and POKO ONE potential-free contact output.
- Cooling water is supplied via a G1/2 male connection; the unit is air-cooled and requires a three-phase 400 V supply.
Behavior under load and media
- The pump delivers up to 45 l/min at a maximum pressure of 0.9 bar, which must overcome the pressure drop of the external circuit.
- Safety class III / FL per DIN 12876 defines permitted fluids and operating conditions; adjustable overtemperature protection must be set for the application.
- The expansion tank lid can be fixed and has connections for a nitrogen blanket at a maximum pressure of 0.2 bar.
Installation and operation
- The unit is delivered with a cable but without a plug; hard-wired connection must be performed by an electrician.
- For externally closed applications the expansion vessel must remain unlocked; for externally open applications it must be locked.
- The controller supports Ethernet, USB (host and device), and RS232 interfaces; a Pt100 external sensor can be connected.
Integration & Operating Notes
The unit draws up to 17 A per phase at 400 V 3~N 50/60 Hz. The site electrical infrastructure, including breaker and cable sizing, must be rated accordingly. Three-phase devices under 63 A are delivered with cable but without a plug, so the customer must provide and install a suitable plug or hard-wire the connection.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage. For externally open applications the expansion vessel must be locked to prevent fluid loss. This setting must be verified before commissioning.
The expansion tank lid can be fixed and has connections for a nitrogen blanket. Exceeding 0.2 bar could damage the tank or create a safety hazard. Ensure the nitrogen supply is regulated to this maximum.
Shut off the cooling water supply even for short downtimes such as overnight to prevent water damage and unnecessary load on the cooling water circuit. Periodically check hoses and connections for leaks and quality, and replace as needed.
When using Process Safety mode for exothermic process protection, the compressor must be set to Permanently ON to keep cooling active at the overtemperature trigger. This ensures cooling remains available if the overtemperature protection activates.
Selection & Integration Q&A
Choose the T402 when your process requires temperatures up to 425 °C and 6 kW heating. The T305 and T305 HT cover lower temperature ranges; select the T402 for high-temperature closed-loop applications where the T305's range is insufficient.
The pump connection is M24x1.5 male, so hoses or adapters must match this thread. The cooling water connection is G1/2 male, requiring a G1/2 female coupling on site. Ensure the external circuit's pressure drop does not exceed the pump's 0.9 bar maximum.
The ambient temperature must stay between 5 °C and 40 °C. The unit must be installed upright, on a level surface with leveling feet or casters locked. It must not be installed in an ATEX zone. Allow 2 hours acclimation after temperature changes before power-on.
Periodically check hoses and connections for leaks and replace as needed. Shut off cooling water during downtimes. The unit is delivered with a cable but without a plug; the customer must provide a suitable plug. No other accessories are included in base delivery.