Peter Huber Kältemaschinenbau Chili Dynamisches
Peter Huber Kältemaschinenbau Chili Dynamisches — Temperature control units.
The Chili Dynamisches is a closed-loop heating circulator (pressure pump, variable speed) rated 65–300 °C with 0.02 K stability, positioned in the Unistate Bis 425C series as the compact 2.7–3 kW modification. Its M24x1.5 male pump connection and 45 l/min / 0.9 bar delivery suit pressure-sensitive glass reactors and jacketed vessels requiring controlled flow.
Peter Huber Kältemaschinenbau Unistate Bis 425C Series — Model Comparison & Selection
| Model | Display resolution | Power supply | Pump connection | Pump type | Temperature range, °C | Expansion volume, m³ |
|---|---|---|---|---|---|---|
| Chili Dynamisches Current | 0.01 | 200-240V 1~/2~ 50/60Hz | M24x1,5 AG male | Pressure pump, variable | 65–300 | 0.002 |
| Unistat T305 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305 HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305w HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T320 Dynamisches | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T320w HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330w HT Dynamisches | 0, 01 K | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T340 Dynamisches | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T340 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T350 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T402 Dynamisches | 0, 01 | 400V 3~N 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 80–425 | — |
| Unistat TR401 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 50–400 | 0.005 |
| Unistat TR402 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 80–425 | — |
Full specifications
| Expansion volume | 2 l |
| Filling volume | 1.45 l |
| Heating capacity | 2.7 - 3 kW |
| Pump connection | M24x1,5 AG male |
| Pump speed adjustable | Yes |
| Pump type | Pressure pump, variable speed |
| External sensor connection | Pt100 |
| Temperature range | 65...300 °C |
| Temperature stability | 0.02 K |
| Alarm message mfr | optic, acoustic, relay |
| Dimensions (W x D x H) mfr | 240 x 427 x 393 mm |
| Delivery capacity pressure pump max. mfr | 45 l/min; 0,9 bar |
| Weight | 23 kg |
| Current consumption | 15.5 A |
| Fuse rating | 16 A |
| Power supply | 200-240V 1~/2~ 50/60Hz |
| Controller | Pilot ONE |
| Display resolution | 0.01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Closed-system heating circulator only; open bath use is excluded by design.
- Compact footprint 240 × 427 × 393 mm, 23 kg, IP20, safety class III / FL.
- Within the Unistate Bis 425C series, this model is the 2.7–3 kW heating variant; siblings T305/T305 HT/T305w HT/T320 are separate modifications — do not assume their ratings apply here.
- Pressure equipment category Art. 4.3 PED; EMC classification EN55011 Class A, Group 1.
Working behavior
- Temperature range 65–300 °C, stability 0.02 K, display resolution 0.01 K.
- Variable-speed pressure pump: max delivery 45 l/min at max delivery pressure 0.9 bar; max permissible kinematic viscosity 50 mm²/s.
- Minimum filling capacity 1.45 l; expansion tank 2 l.
- Adjustable overtemperature protection per DIN 12876; external Pt100 sensor connection available.
- Alarm signaling via optic, acoustic and relay outputs.
Control, installation and operation
- Pilot ONE controller; interfaces Ethernet, USB (host and device), RS232.
- Power: 200–240 V 1~/2~ 50/60 Hz, max current 15.5 A, 16 A fuse; external branch protection per UL 489 required; hard-wired connection by an electrician; power cable max 3 m.
- Pump connection M24x1.5 male, bore shape Y (60°) per DIN 3863, ball socket DIN 3863, sleeve nut DIN 3870.
- After Stop the pump overruns about 30 seconds; thermal fluid must be brought to room temperature before switching off to avoid overpressure.
Integration & Operating Notes
The manual explicitly prohibits installation or startup within an ATEX zone due to explosion risk; site classification must be confirmed before the unit is placed, regardless of the process fluid used.
The responsible body must install a condensation water / thermal fluid drip tray below the unit, and any casters must be locked after installation to prevent crushing of limbs during operation and service.
The unit does not include branch circuit protection; an external breaker or fuse according to UL 489 must be provided. Supply must be 200–240 V 1~/2~ 50/60 Hz with 16 A fuse, and voltage/frequency tolerance is ±5% / ±2% with some combinations not allowed.
Single- and two-phase devices are delivered with a power cable and country-specific plug that must be stated when ordering; hard-wired connection must be performed by an electrician and the power cable must not exceed 3 m.
For pressure-sensitive applications such as glass reactors, the maximum flow pressure of 0.9 bar must be taken into account; the variable-speed pump allows flow to be reduced, but the pressure limit remains the governing constraint for the connected circuit.
Temperature control hoses should be as short as possible and their inside diameter must at least match the M24x1.5 pump connections; undersized or long hoses increase pressure drop and degrade achievable temperature control performance.
To prevent overpressure in the system, the thermal fluid must always be adjusted to room temperature before switching off; after pressing Stop the pump continues to run for about 30 seconds, so service or draining must wait for that overrun.
When changing from a cold to a warm environment (or vice versa), the unit must acclimate for about 2 hours before switching on; ambient temperature during operation must remain between 5 °C and 40 °C.
Selection & Integration Q&A
Pick this model for closed-loop heating up to 300 °C with 2.7–3 kW and a compact 240 mm width. The T305/T305 HT/T305w HT/T320 are separate modifications; their ratings must be checked individually and are not interchangeable with this unit's 65–300 °C range.
Mating hoses need M24x1.5 female fittings with bore shape Y (60°) per DIN 3863, ball socket DIN 3863 and sleeve nut DIN 3870, with inside diameter at least matching the pump connection. Supply: 200–240 V 1~/2~ 50/60 Hz, 16 A fuse, external UL 489 branch protection, max 3 m power cable.
No ATEX zone; ambient 5–40 °C; drip tray below the unit; casters locked; 2 h acclimation after cold/warm moves; thermal fluid viscosity max 50 mm²/s; fluid cooled to room temperature before switch-off; pump overruns about 30 s after Stop.
External branch circuit protection per UL 489 and the drip tray are site-provided; the country-specific plug must be specified at order. Temperature control hoses and fittings are not part of the unit. Service follows the manual's Service and Maintenance section; no consumables are listed in the verified facts.