Peter Huber Kältemaschinenbau Unistat T305w HT Dynamisches
Peter Huber Kältemaschinenbau Unistat T305w HT Dynamisches — Temperature control units.
The Unistat T305w HT is a water-cooled, dynamically temperature-controlled pressure-pump unit with a 65–300 °C range (15–300 °C with water cooling), positioned above the air-cooled T305 HT and below the T320 in the Unistat series. Its variable-speed pressure pump delivers up to 45 l/min at 0.9 bar, making it suited to closed-loop tempering of reactors and process equipment requiring high-temperature stability.
Peter Huber Kältemaschinenbau Unistate Bis 425C Series — Model Comparison & Selection
| Model | Display resolution | Power supply | Pump connection | Pump type | Temperature range, °C | Expansion volume, m³ |
|---|---|---|---|---|---|---|
| Unistat T305w HT Dynamisches Current | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Chili Dynamisches | 0.01 | 200-240V 1~/2~ 50/60Hz | M24x1,5 AG male | Pressure pump, variable | 65–300 | 0.002 |
| Unistat T305 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305 HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T320 Dynamisches | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T320w HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330w HT Dynamisches | 0, 01 K | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T340 Dynamisches | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T340 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T350 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T402 Dynamisches | 0, 01 | 400V 3~N 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 80–425 | — |
| Unistat TR401 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 50–400 | 0.005 |
| Unistat TR402 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 80–425 | — |
Full specifications
| Control output | POKO ONE (potential-free contact) |
| Maximum delivery flow rate | 45 l/min (pressure pump max.; also 0, 9 bar) |
| Pump connection | M24x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | Pressure pump, variable speed |
| External sensor connection | Pt100 |
| Temperature range | 65...300 °C with water cooling: 15...300 °C |
| Weight | 42 kg |
| Current consumption | 15 A (max.) |
| Power supply | 200-240V 1~/2~ 50/60Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s (max. permissible) |
| Ambient temperature limit | 5...40 °C (permissible) |
| Cooling water connection | G1/2 male |
| Cooling water differential pressure | 1 bar (min.) |
| Cooling Water Pressure | 6 bar (max.) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Water-cooled variant of the T305 HT: the 'w' denotes cooling-water heat rejection, enabling a 15 °C lower range limit (15–300 °C) versus the 65–300 °C of the air-cooled T305 HT.
- Sits between the T305 HT (air-cooled, same nominal capacity) and the larger T320 in the Unistat series; the Chili Dynamisches is a separate, lower-temperature line.
- Variable-speed pressure pump, M24x1.5 AG male pump connection, G1/2 male cooling-water connection; 42 kg, IP20, Class III/FL safety class.
- Pilot ONE controller with POKO ONE potential-free contact output; Pt100 external sensor input; Ethernet, USB host/device and RS232 interfaces; 0.01 K display resolution.
Behavior and media limits
- Temperature range 65–300 °C without water cooling, extended down to 15 °C when water cooling is active.
- Cooling power ratings are referenced to 20 °C room temperature, 15 °C cooling-water inlet and 1 bar differential pressure; higher cooling-water temperature reduces cooling power and may require increased flow.
- Water exit temperature is limited to 55 °C and no steam exits when cooling at circulation temperatures above 100 °C.
- Maximum permissible viscosity 50 mm²/s; pump speed adjustable.
Installation, connection and operation
- Cooling water must be 5–20 °C inlet with at least 1 bar differential pressure; insulate cooling-water pipes if below the condensation point; circuit materials include copper, 1.4401 stainless steel, MS, PA, PPE, PTFE and EPDM.
- Power: 200–240 V 1~/2~ 50/60 Hz, max 15 A; voltage tolerance ±10% only if frequency tolerance does not run opposite; single/two-phase units ship with country-specific plug (specify at order); external branch protection per UL 489 required.
- Expansion vessel must be unlocked for externally closed applications and locked for externally open applications.
- Process Safety mode requires the compressor set to Permanently ON; Power Failure Auto resumes control after outage if active.
Integration & Operating Notes
The unit requires cooling water inlet temperature between 5 °C and 20 °C and at least 1 bar differential pressure. Outside this window cooling power drops and flow demand rises, so the site water supply must be confirmed during selection; if inlet temperature falls below the condensation point, the internal cooling-water pipes must be insulated.
Voltage tolerance is ±10% only if the frequency tolerance does not run in the opposite direction, so supply quality must be verified. External branch circuit protection according to UL 489 is required. Single/two-phase units are delivered with a country-specific plug that must be specified at order; hard-wired connection must be performed by an electrician.
Only transport and store the unit upright and only when emptied; horizontal transport damages the compressor. Casters are not for transport and carry only 25% of total mass symmetrically. Before commissioning, activate parking brakes and unscrew leveling feet. After moving between cold and warm environments, allow about 2 hours acclimation before power-on to prevent condensation-induced faults.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage to the application. For externally open applications the expansion vessel must be locked to prevent fluid loss. This setting must be confirmed at commissioning and whenever the application circuit type changes.
If Process Safety mode is used for exothermic process protection, the compressor must be configured to Permanently ON so cooling remains active at the over-temperature trigger. Power Failure Auto resumes temperature control automatically after a power outage if it was active, which affects unattended operation risk assessment.
Shut off the cooling water supply even for short downtimes such as overnight to prevent water damage and unnecessary load on the circuit. Periodically check hoses and hose connections for leaks and quality and replace as required.
Selection & Integration Q&A
Pick the T305w HT when you need the range extended down to 15 °C via water cooling and have a suitable 5–20 °C water supply; the air-cooled T305 HT stops at 65 °C. Choose the T320 only if its larger capacity is required.
Cooling-water connection is G1/2 male with 5–20 °C inlet and ≥1 bar differential pressure; pump connection is M24x1.5 AG male with bore shape Y (60°) per DIN 3863, requiring ball socket per DIN 3863 and sleeve nut per DIN 3870 on hoses.
Install within 5–40 °C ambient, IP20, free of water ingress, and never inside an ATEX zone. Transport upright and empty; allow 2 h acclimation after temperature changes; activate leveling feet and brakes before commissioning.
Base delivery includes cable and country-specific plug for single/two-phase (specify at order); external UL 489 branch protection and mating hoses/fittings are customer-supplied. Shut off cooling water for short downtimes and periodically inspect/replace hoses and connections.