Agilent Technologies High-throughput Purification | Drug discovery | Biological
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies High-throughput Purification | Drug discovery | Biological

Agilent Technologies High-throughput Purification | Drug discovery | Biological — Liquid chromatography.

The Agilent high-throughput purification system is a preparative HPLC configuration for drug discovery and biological applications, accepting columns of 1–3 in internal diameter. It achieves 97% fraction purity and 96% recovery at 1 mL/min with 254 nm detection. This modification is positioned for high-throughput purification within the InfinityLab preparative series.

Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection

Model Column inner diameter, mmTypical flow rate, mL/minPlate count, Nth/meterRetention time, minCarryover, %Sample capacity
High-throughput Purification | Drug discovery | Biological Current 1...314060615.18——
1220 Infinity II Analytical-Scale LC Purification System 4.61————
1260 Analytical-Scale Purification System | Preparative HPLC 1...314060615.18——
1260 Infinity Bio-Inert Analytical-Scale LC Purification System 1...314060615.18——
1260 Infinity II Manual Preparative LC System 1...314060615.18——
1260 Infinity II Preparative LC System | UV based Prep HPLC 1...314060615.185132
1260 Prime Bio Analytical-Scale Purification System 4.61——9×10⁻⁴6144
1290 Analytical-Scale LC Purification 1...314060615.18——
1290 Infinity Autoscale Preparative system 1...314060615.18——
1290 Infinity III 4.61——9×10⁻⁴6144
1290 Infinity II Preparative LC System 1...314060615.18——
Automated LC/MSD purification| High-precision| Complex mixtures 1...314060615.18——
Flexible HPLC/UHPLC, Prime Analytical-Scale Purification System 1...314060615.18——
Preparative LC/MSD System | Enhanced Purification & Efficiency 1...314060615.18——

Full specifications

Core Performance & Functional Specifications
Detection wavelength 254 nm
Fraction Purity 97 %
Fraction Recovery 96 %
Plate Count 40606 Nth/meter
Retention Time 15.18 min
Typical Flow Rate 1 mL/min
Uv Threshold 1 mAU/s
Productivity range mfr Micrograms Micrograms
Asymmetry mfr 1.27
Column inside diameter range mfr 9.4 mm
Gradient end point mfr 3.50 % B
Stop time mfr 5.10 minutes
Membrane pore size mfr 0.22 μm
Dimensions, Weight & Mechanical Design
Column Inner Diameter 1...3 in

Description

Construction and series positioning

Performance characteristics

Installation and operation

Integration & Operating Notes

Process Limits
Column pressure must remain within hardware limits

Exceeding the maximum pressure rating of the preparative flow path can damage columns and seals. Always verify backpressure at the typical flow rate of 1 mL/min with the installed column dimensions (1–3 in id) and adjust gradient or flow if pressure approaches the limit.

Technical Overview 5991-8159EN, Section on Preparative Binary Pump
Maintenance
Replace 0.22 µm membrane filters at defined intervals

The 0.22 µm membrane pore size referenced in the column documentation indicates filtration of mobile phases and samples. Clogged filters cause baseline noise and pressure spikes; establish a replacement schedule based on solvent volume and sample load to maintain 97% fraction purity.

Load & Lock Columns brochure 5994-3907EN
Control & I/O
UV threshold triggers fraction collection at 1 mAU/s

The UV threshold of 1 mAU/s is used to initiate peak-based fraction collection. Ensure the detector signal is properly calibrated and the threshold is set above baseline noise to avoid false triggers; integrate with the fraction collector via the control software for synchronized operation.

Brochure 5991-9154EN, InfinityLab LC Purification Solutions

Selection & Integration Q&A

When should I choose this high-throughput purification system over the 1260 Infinity II Manual Preparative LC System?

Choose this model for automated high-throughput purification with fraction collection and UV threshold triggering (1 mAU/s), achieving 97% purity and 96% recovery. The manual preparative system is suited for lower-throughput, hands-on operation without integrated automation.

What are the requirements for connecting a fraction collector to this system?

The system integrates with InfinityLab fraction collectors (valve-based or open-bed) via the control software. Ensure the collector's tubing and fittings are compatible with the preparative flow path (1–3 in id columns) and that the UV threshold signal (1 mAU/s) is routed to trigger collection.

What maintenance items and accessories are not included in the base delivery?

The base system does not include preparative columns (1–3 in id), mobile packing stations, or replacement membrane filters (0.22 µm). Additionally, solvent filtration kits, spare seals, and validation kits are typically ordered separately. Refer to the accessories list in the brochure for details.

Dimensional Drawings & Technical Documentation

Technical documentation