Agilent Technologies 1260 Infinity II Manual Preparative LC System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1260 Infinity II Manual Preparative LC System

Agilent Technologies 1260 Infinity II Manual Preparative LC System — Liquid chromatography with Pumping speed 0.012 m³/h.

The 1260 Infinity II Manual Preparative LC System is a preparative-scale HPLC configuration built around a manual injector and open-bed fraction collection, accepting columns of 1 to 3 in internal diameter. It sits between the analytical-scale purification systems and the UV-directed preparative LC system in the 1260 series, and is intended for hands-on purification of milligram-to-gram quantities where the operator controls injection and fraction cutting.

Pumping speed
0.012 m³/h

Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection

Model Column inner diameter, mmTypical flow rate, mL/minPlate count, Nth/meterRetention time, minCarryover, %Sample capacity
1260 Infinity II Manual Preparative LC System Current 1...314060615.18——
1220 Infinity II Analytical-Scale LC Purification System 4.61————
1260 Analytical-Scale Purification System | Preparative HPLC 1...314060615.18——
1260 Infinity Bio-Inert Analytical-Scale LC Purification System 1...314060615.18——
1260 Infinity II Preparative LC System | UV based Prep HPLC 1...314060615.185132
1260 Prime Bio Analytical-Scale Purification System 4.61——9×10⁻⁴6144
1290 Analytical-Scale LC Purification 1...314060615.18——
1290 Infinity Autoscale Preparative system 1...314060615.18——
1290 Infinity III 4.61——9×10⁻⁴6144
1290 Infinity II Preparative LC System 1...314060615.18——
Automated LC/MSD purification| High-precision| Complex mixtures 1...314060615.18——
Flexible HPLC/UHPLC, Prime Analytical-Scale Purification System 1...314060615.18——
High-throughput Purification | Drug discovery | Biological 1...314060615.18——
Preparative LC/MSD System | Enhanced Purification & Efficiency 1...314060615.18——

Full specifications

Core Performance & Functional Specifications
Pumping speed 200 mL/min
Plate Count 40606 Nth/meter
Retention Time 15.18 min
Typical Flow Rate 1 mL/min
Productivity range mfr Grams Grams
Asymmetry mfr 1.27
pressure at 50 mL/min mfr 600 bar
pressure at 200 mL/min mfr 420 bar
maximum flow rate (1260) mfr 50 mL/min
sample capacity (Open-Bed) mfr 864 samples
fraction capacity (Open-Bed) mfr 432 fractions
maximum fraction capacity mfr 1296 fractions
fractions per module (1260) mfr 216 fractions
expandable fraction capacity (1260) mfr 648 fractions
injection volume (1260 sampler) mfr 3.6 mL
sample capacity (1260 sampler) mfr 132 samples
sample loading increase (Load & Lock) mfr 20
Dimensions, Weight & Mechanical Design
Column Inner Diameter 1...3 in
maximum column inner diameter (1290) mfr 50 mm
maximum column inner diameter (1260) mfr 30 mm

Description

Construction and positioning in the series

The 1260 Infinity II Manual Preparative LC System is the manual-injection member of the 1260 preparative family. Unlike the UV-based preparative system, which automates fraction detection and cutting, this configuration relies on the operator to inject via a manual injector and to collect fractions from an open-bed collector. It is distinguished from the 1220 and 1260 analytical-scale purification systems by its preparative column capacity: the load-and-lock column range covers 1 to 3 in internal diameter (27 to 75 mm), whereas analytical-scale siblings are limited to analytical columns. The Bio-Inert variant is the choice when biological samples require inert flow path; this standard preparative system is the general-purpose option.

Behavior and performance context

Verified performance data for this exact configuration are limited to a plate count of 40,606 N/m, a retention time of 15.18 min and a typical flow rate of 1 mL/min, with peak asymmetry of 1.27. These values describe a chromatographic separation at analytical-like flow on a preparative column, not a high-throughput production run; the system is therefore suited to method development and scale-up studies before transferring to automated preparative platforms. The 1 to 3 in column range allows the same hardware to run small and larger preparative columns, but the operator must expect flow rate and backpressure to scale with column diameter.

Installation, control and operation

From the portfolio documentation, the system is assembled from preparative modules: column organizer, column compartment, manual injector, open-bed sampler/collector, detectors and fraction collector. The load-and-lock columns are available in dynamic axial compression (DAC) and static axial compression (SAC) modes with standard stainless steel water jackets, and mobile packing stations exist for 1, 2 and 3 in id columns. Installation therefore requires planning for column packing and unpacking equipment, jacket cooling water, and manual fraction handling. Control is local and manual for injection and collection; no automated fraction-cutting logic is part of this configuration.

Integration & Operating Notes

Mounting
Column hardware must match the 1–3 in id load-and-lock range

The system is documented for load-and-lock columns of 1 to 3 in internal diameter (27 to 75 mm). Fitting a column outside this range, or a non-load-and-lock column, requires separate fittings and is not covered by the system documentation; confirm column end fittings and jacket connections before ordering.

Agilent Load & Lock Columns brochure 5994-3907EN
Process Limits
Choose DAC or SAC packing mode before commissioning

Load-and-lock columns are offered in dynamic axial compression (DAC) and static axial compression (SAC) modes. The packing station and operating procedure differ between modes, so the mode must be fixed at the selection stage; the mobile packing stations are sized for 1, 2 and 3 in id columns and are not interchangeable across diameters.

Agilent Load & Lock Columns brochure 5994-3907EN
Cooling & Media
Water jacket connections are standard on preparative columns

Standard stainless steel water jackets are part of the column hardware. Installation planning must provide jacket coolant supply and return lines at the column location; the jacket is a column feature, not a system module, so the coolant circuit is the user's responsibility.

Agilent Load & Lock Columns brochure 5994-3907EN
Control & I/O
Manual injection and open-bed collection define the workflow

This configuration uses a manual injector and an open-bed sampler/collector rather than an automated fraction collector with UV-triggered cutting. Operators must plan fraction cutting by hand and provide the detector signal display; the UV-based preparative sibling is the alternative when automated fraction detection is required.

InfinityLab LC Purification Solutions brochure 5991-9154EN
Maintenance
Column packing and unpacking require the matching mobile station

Mobile packing stations are listed for 1, 2 and 3 in id columns. Packing or unpacking a column without the correct station for its diameter is not supported by the documentation; schedule station availability and operator training as part of commissioning rather than treating packing as an accessory.

Agilent Load & Lock Columns brochure 5994-3907EN

Selection & Integration Q&A

When should I choose the 1260 Infinity II Manual Preparative LC System instead of the UV-based preparative system or an analytical-scale purification system?

Pick the manual system when the operator will inject by hand and cut fractions from an open-bed collector, and when columns of 1–3 in id are needed. Choose the UV-based preparative system for automated UV-triggered fraction cutting; choose the 1220/1260 analytical-scale systems for analytical columns only.

What column hardware and packing equipment must be ordered alongside this system?

Load-and-lock columns in 1, 2 or 3 in id, in either DAC or SAC mode, with standard stainless steel water jackets. A mobile packing station matched to the column diameter is required for packing and unpacking; these are separate items from the LC system itself.

What installation conditions does the preparative column hardware impose on the lab?

The columns carry standard stainless steel water jackets, so coolant supply and return lines must be routed to the column position. The 1–3 in id columns and their packing stations occupy bench space beyond the LC modules; plan the column organizer and packing station footprint before installation.

Which items are not included in the base system and must be sourced separately?

Preparative load-and-lock columns, the mobile packing station for the chosen column diameter, and jacket coolant plumbing are separate from the LC system. Fraction collection vessels for the open-bed collector and any detector-specific flow cells are also user-supplied.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Purify Your Samples with Agilent Infinity II Purification Systems
Brochure ·2,0 МБ ·16 pp.
View PDF