Peter Huber Kältemaschinenbau Unistat 410w Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat 410w Dynamisches

Peter Huber Kältemaschinenbau Unistat 410w Dynamisches — Temperature control units with Noise level 61 dB.

The Unistat 410w Dynamisches is a water-cooled, free-standing temperature control unit with a variable-speed pressure pump and Pilot ONE controller, covering -45 to 250 °C with 3 kW heating. Its water-cooled refrigeration (R-1270, A3) distinguishes it from air-cooled siblings, requiring a 5–20 °C cooling water circuit. It serves precise temperature control of externally closed or open applications in process engineering.

Noise level
61 dB

Peter Huber Kältemaschinenbau Unistate Bis 45C Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionPower supplyPump connectionPump typeTemperature range, °C
Unistat 410w Dynamisches Current 610, 01 K220-240V 1~/2~ 50/60HzM24x1, 5 AG malePressure pump, variable -45–250
Grande Fleur Dynamisches ——————
Grande Fleur w Dynamisches —0, 01208-240V 1~/2~ 50/60HzM24x1, 5 AG malePressure pump, variable -40–200
Grande Fleur w-eo Dynamisches ——————
Petite Fleur-eo Dynamisches 580, 01 K220-240V 1~/2~ 50/60HzM16x1 AG malePressure pump, variable -40–200
Petite Fleur w Dynamisches —0, 01220-240V 1~/2~ 50/60HzM16x1 AG malePressure pump, variable -40–200
Unistat 425w Dynamisches 610, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250
Unistat 430w Dynamisches 610, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250
Unistat P405w Dynamisches —0, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st-45–250
Unistat P425 Dynamisches 650, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250
Unistat P425w Dynamisches 610, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250
Unistat P430 Dynamisches 650, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250
Unistat P430w Dynamisches 650, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st-40–250

Full specifications

Core Performance & Functional Specifications
Noise level 61 dB(A) (sound pressure level)
Control output POKO ONE (potential-free contact)
Heating capacity 3 kW
Pump connection M24x1, 5 AG male
Pump speed adjustable Yes
Pump type Pressure pump, variable speed
External sensor connection Pt100
Temperature range -45...250 °C
Dimensions, Weight & Mechanical Design
Weight 68 kg (net)
Electrical, Power & Drive Specifications
Current consumption 16 A (max)
Fuse rating 16 A
Power supply 220-240V 1~/2~ 50/60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s (max permissible)
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C (permissible)
Cooling water connection G1/2 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Working range and behavior

Installation, control and operation

Integration & Operating Notes

Cooling & Media
Cooling water must stay within 5–20 °C and 1–6 bar

The water-cooled refrigeration circuit is designed for inlet water between 5 °C and 20 °C; warmer water reduces cooling power and raises required flow, while pressure below 1 bar differential or above 6 bar risks inadequate flow or overpressure. Insulate cooling water pipes when water temperature falls below the condensation point to prevent moisture damage.

Unistat 410w Technical Data, page 2
Electrical
Supply must be 220–240 V with 16 A protection and stable quality

The unit draws up to 16 A and requires a 16 A fuse; voltage tolerance ±5% and frequency tolerance ±2% must not be combined in the unfavorable direction. At 230 V the maximum current is just under 16 A and the unit can be limited to 13 A or 10 A at first start-up, which affects upstream breaker sizing. Hard-wired connection must be performed by an electrician.

Unistat 410w Technical Data, page 2; Unistat Operation Manual, page 37
Process Limits
Expansion vessel setting depends on open vs closed application

For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage. For externally open (bath) applications the expansion vessel must be locked to prevent fluid loss. This valve setting must be verified before filling and venting.

Unistat Operation Manual, page 33
Process Limits
Heat transfer fluid viscosity must not exceed 50 mm²/s

The variable-speed pressure pump is limited to a maximum permissible kinematic viscosity of 50 mm²/s; selecting a fluid that is too viscous at low temperatures will overload the pump and compromise circulation. For FL-rated fluids, the fire point must be ≥65 °C, and ethanol use requires supervised operation.

Unistat 410w Technical Data, page 2; Unistat Operation Manual, Section 1.7
Mounting
Install level, upright, with drip tray and no ATEX zone

The unit must be transported and stored upright only, moved only when emptied, and set on leveling feet or parking brakes before commissioning. A condensation water/heat transfer fluid drip tray must be installed below the unit. Installation inside an ATEX zone is prohibited; explosion protection requires an Ex px cabinet.

Unistat Operation Manual, pages 15, 22; Section 1.4
Control & I/O
Process Safety mode requires compressor set to Permanently ON

In Process Safety mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles; this mode requires the compressor to be set to Permanently ON. Power Failure Auto can resume temperature control automatically after an outage if it was active, so choose the restart behavior according to whether unattended restart is acceptable.

Unistat Operation Manual, pages 19–20
Maintenance
Shut off cooling water even for overnight downtime

The cooling water supply should be shut off even for short downtimes such as overnight to prevent water damage and unnecessary load on the circuit. Hoses and connections must be periodically checked for leaks and quality and replaced as needed. Refrigerant-circuit work is restricted to approved refrigeration/air-conditioning contractors.

Unistat Operation Manual, page 29; Section 1.4.2

Selection & Integration Q&A

When should I choose the Unistat 410w Dynamisches instead of an air-cooled or non-dynamic sibling?

Choose the 410w when a cooling water circuit (5–20 °C, 1–6 bar differential) is available and air-cooled heat rejection is impractical. The 'Dynamisches' modification suits rapid temperature changes; the 410(w) has no plate heat exchanger, so the usual fatigue warning for rapid cycling does not apply in the same way.

What cooling water and pump connections are required for integration?

Cooling water: G1/2 male, inlet 5–20 °C, minimum 1 bar differential, maximum 6 bar. Pump circuit: M24x1.5 male. Insulate cooling water pipes if water is below the condensation point. Ensure heat transfer fluid viscosity ≤50 mm²/s.

What are the electrical and ambient limits for installation?

Supply 220–240 V 1~/2~ 50/60 Hz, max 16 A, 16 A fuse; voltage ±5% and frequency ±2% must not combine unfavorably. Ambient 5–40 °C, IP20, EMC Class A Group 1. Hard-wired connection by an electrician; allow ~2 h acclimation after cold/warm moves.

What maintenance and accessories are not included in base delivery?

Cooling water hoses/fittings (G1/2 male) and pump hoses/adapters (M24x1.5 male) are not included. A drip tray must be provided by the installer. Periodic checks of hoses and connections are required; refrigerant work only by approved contractors. Optional gas detection sensor and processing unit are stand-alone accessories.