Peter Huber Kältemaschinenbau Unichiller 025-H
Peter Huber Kältemaschinenbau Unichiller 025-H — Enfriadores de recirculación con Nivel de ruido 64 dB.
El Unichiller 025-H es un enfriador de recirculación refrigerado por aire, monofásico, con bomba de inmersión y controlador Pilot ONE, que cubre de -10 a 100 °C. Dentro de la serie Unichiller es la variante 025 de mayor capacidad, distinguida por su caudal de bomba de 29 l/min y una corriente máxima de 16 A. Sirve a circuitos de refrigeración cerrados externos en procesos industriales.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Modelo | Nivel de ruido, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Unichiller 025-H Actual | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015w-H OLÉ | 54 | OLÉ | I / NFL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 017T | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017T-H | 64 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017Tw-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020T | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020T-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020Tw | 60 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw-H | 60 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 022-H | 65 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022w-H | — | Pilot ONE | III / FL | -10–100 | — | — |
| Unichiller 022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025T | 74 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025T-H | 74 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025Tw-H | — | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P007 | 58 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007-H | — | Pilot ONE | III / FL | -20–100 | — | — |
| Unichiller P007-H OLÉ | 58 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007 OLÉ | 58 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P010 | 57 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P010-H | 57 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010-H OLÉ | 57 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010 OLÉ | 57 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 50/60Hz |
| Unichiller P010w | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 | 59 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P012-H | 59 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012-H OLÉ | 59 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 OLÉ | 59 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H OLÉ | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208V 2~ 60Hz |
| Unichiller P012w OLÉ | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015 OLÉ | 63 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015w | 54 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P015w-H OLÉ | 54 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50Hz |
| Unichiller P022 | 65 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H | 65 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P022w-H | 60 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P025 | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
Especificaciones completas
| Nivel de ruido | 64 dB(A) |
| Caudal máximo de impulsión | 29 l/min (pressure pump max; 1 bar) |
| Conexión de bomba | G3/4 AG male |
| Velocidad de bomba ajustable | Yes |
| Tipo de bomba | Immersion pump |
| Conexión de sensor externo | Pt100 |
| Rango de temperatura | -10...100 °C |
| Peso | 77 kg |
| Consumo de corriente | 16 A (max) |
| Valor nominal del fusible | 20 A |
| Alimentación | 220-240V 1~ 50Hz |
| Controlador | Pilot ONE |
| Interfaz digital | Ethernet, USB (Host u. Device), RS232 |
| Límite de temperatura ambiente | 5...40 °C |
| Clase de protección | IP20 |
| Clase de seguridad | III / FL |
Descripción
Construcción y posicionamiento en la serie
- El 025-H es un enfriador autónomo refrigerado por aire que utiliza refrigerante inflamable R-290 (carga de 0.25 kg, GWP 0.02) y una bomba de inmersión con conexiones macho G3/4 AG.
- En comparación con los hermanos Unichiller 015 (63 dB(A)), esta variante 025-H tiene una clasificación de 64 dB(A) y consume hasta 16 A en una alimentación monofásica de 220–240 V a 50 Hz, requiriendo un fusible de 20 A.
- El controlador Pilot ONE proporciona interfaces Ethernet, USB (host y dispositivo) y RS232, además de una entrada para sensor externo Pt100.
- La clasificación de seguridad es III / FL según DIN 12876 con protección ajustable contra sobretemperatura.
Comportamiento bajo carga y limitaciones del medio
- La unidad está destinada únicamente a aplicaciones cerradas externamente; no está protegida contra explosiones y no debe instalarse en una zona ATEX.
- La capacidad de refrigeración está nominalizada a 20 °C de temperatura ambiente y disminuye a medida que aumenta la temperatura ambiente; el rango ambiente admisible es de 5–40 °C.
- La bomba de plástico no es resistente a la acetona ni a los poliglicoles, por lo que estos no deben utilizarse como medios de transferencia de calor. Para protección contra heladas por debajo de 0 °C, el agua debe mezclarse con glisantina o etilenglicol.
- La bomba es de velocidad ajustable y entrega un máximo de 29 l/min a 1 bar.
Instalación, control y operación
- Se requiere una separación de pared de 50–200 cm por lado para el mantenimiento en modelos autónomos; la unidad debe utilizarse en interiores con una iluminancia de al menos 300 lx y hasta 2000 m de altitud.
- Las patas niveladoras deben activarse y los frenos de estacionamiento aplicarse antes de la puesta en marcha. No deben superarse los pares de apriete máximos para las conexiones de la bomba, y las conexiones deben sujetarse con contraherramienta.
- La respuesta ante fallo de alimentación es configurable mediante Pilot ONE como OFF/Standby, ON o Power Failure Auto. El modo Process Safety libera la máxima capacidad de refrigeración cuando se alcanza el disparo de sobretemperatura.
- La unidad es EMC Clase A, Grupo 1 (EN55011), destinada a entornos industriales. Debe especificarse un enchufe específico del país al realizar el pedido.
Integration & Operating Notes
Selection & Integration Q&A
Elija el 025-H cuando su proceso necesite un caudal de bomba mayor (29 l/min) y pueda aceptar una corriente máxima de 16 A con un fusible de 20 A; los modelos 015 son de menor capacidad (63 dB(A)) y se adaptan a cargas más pequeñas. El 025-H también ofrece el mismo controlador Pilot ONE y las mismas interfaces.
Los trabajos en el circuito de refrigerante deben ser realizados por contratistas certificados. El enchufe específico del país debe pedirse por separado. Para la protección contra heladas, mezcle agua con glysantine o etilenglicol. La bomba de plástico es incompatible con acetona y poliglicoles. No se incluyen cables ni mangueras en la entrega básica.