Peter Huber Kältemaschinenbau Unichiller P010
Peter Huber Kältemaschinenbau Unichiller P010 — Enfriadores de recirculación con Nivel de ruido 57 dB.
El Unichiller P010 es un enfriador de recirculación con bomba de plástico y controlador Pilot ONE, clasificado para -20 a 40 °C y alimentación de 208 V bifásica 60 Hz. Su designación 'P' indica idoneidad para aplicaciones de alta caída de presión, lo que lo distingue de sus hermanos de la serie 015. Sirve a circuitos de refrigeración cerrados externamente que requieren hasta 25 l/min a 2,5 bar.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Modelo | Nivel de ruido, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Unichiller P010 Actual | 57 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015w-H OLÉ | 54 | OLÉ | I / NFL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 017T | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017T-H | 64 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017Tw-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020T | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020T-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020Tw | 60 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw-H | 60 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 022-H | 65 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022w-H | — | Pilot ONE | III / FL | -10–100 | — | — |
| Unichiller 022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025T | 74 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025T-H | 74 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025Tw-H | — | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P007 | 58 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007-H | — | Pilot ONE | III / FL | -20–100 | — | — |
| Unichiller P007-H OLÉ | 58 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007 OLÉ | 58 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P010-H | 57 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010-H OLÉ | 57 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010 OLÉ | 57 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 50/60Hz |
| Unichiller P010w | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 | 59 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P012-H | 59 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012-H OLÉ | 59 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 OLÉ | 59 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H OLÉ | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208V 2~ 60Hz |
| Unichiller P012w OLÉ | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015 OLÉ | 63 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015w | 54 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P015w-H OLÉ | 54 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50Hz |
| Unichiller P022 | 65 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H | 65 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P022w-H | 60 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P025 | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
Especificaciones completas
| Nivel de ruido | 57 dB(A) |
| Caudal máximo de impulsión | 25 l/min (pressure pump max; also 2, 5 bar) |
| Conexión de bomba | G3/4 AG male |
| Velocidad de bomba ajustable | no |
| Tipo de bomba | B |
| Conexión de sensor externo | Pt100 |
| Rango de temperatura | -20...40 °C |
| Peso | 56 kg |
| Valor nominal del fusible | 10 A |
| Alimentación | 208V 2~ 60Hz |
| Controlador | Pilot ONE |
| Interfaz digital | Ethernet, USB (Host u. Device), RS232 |
| Límite de temperatura ambiente | 5...40 °C |
| Clase de protección | IP20 |
| Clase de seguridad | I / NFL |
Descripción
Construcción y posicionamiento en la serie
- El P010 es un enfriador de recirculación de instalación libre en la serie Unichiller, que utiliza una bomba de plástico (tipo B) con conexiones macho G3/4 y un controlador Pilot ONE.
- A diferencia de sus hermanos 015 (63 dB(A)), el P010 es más silencioso con 57 dB(A) y está marcado específicamente con 'P' para aplicaciones de alta caída de presión, según el manual.
- Está destinado únicamente a circuitos cerrados externamente y no debe instalarse en zonas ATEX.
Rendimiento y comportamiento del medio
- La capacidad de refrigeración depende fuertemente de la temperatura: 1 kW a +15 °C, 0,8 kW a 0 °C, 0,5 kW a -10 °C y 0,15 kW a -20 °C, válido a 20 °C de temperatura ambiente.
- La bomba entrega hasta 25 l/min y 2,5 bar, pero el caudal cae a 6 l/min a 2,0 bar, por lo que los circuitos de alta caída de presión deben verificarse contra la curva de la bomba.
- La bomba de plástico no es resistente a acetona ni a poliglicoles; para operación bajo cero, el agua debe mezclarse con glisantina o etilenglicol para protección contra congelamiento.
Instalación, control y operación
- Requiere alimentación de 208 V 2~ 60 Hz con fusible de 10 A; los dispositivos trifásicos por debajo de 63 A se suministran con cable pero sin enchufe.
- Protección IP20, ambiente de 5–40 °C, uso solo en interiores con iluminancia ≥300 lx y altitud hasta 2000 m.
- Se requiere un espacio libre de pared de 50–200 cm por lado para mantenimiento; las patas niveladoras o los frenos de estacionamiento deben estar accionados antes de la operación.
- El controlador Pilot ONE ofrece interfaces Ethernet, USB (host y dispositivo) y RS232, y admite respuesta configurable ante fallo de alimentación (OFF/Standby, ON, Power Failure Auto) y modo de Seguridad de Proceso para procesos exotérmicos.
Integration & Operating Notes
A -20 °C el enfriador proporciona solo 0,15 kW, frente a 1 kW a +15 °C. Dimensione la carga del proceso según el punto de ajuste real, no según el máximo nominal, o la unidad no mantendrá la temperatura.
La unidad está configurada para 208 V 2~ 60 Hz y consume máx. 6,5 A. Las tolerancias de tensión y frecuencia son ±5% y ±2%, pero no se permiten desviaciones combinadas en el peor caso en la misma dirección.
Los modelos de instalación libre requieren un espacio libre de pared de 50 a 200 cm a cada lado para mantenimiento. Asegúrese también de una ubicación en interiores con iluminancia ≥300 lx y altitud ≤2000 m.
La bomba de plástico estándar no es resistente a acetona ni a poliglicoles (según el fabricante). Especifique una bomba alternativa o evite estos fluidos para prevenir fallos de la bomba.
El Pilot ONE permite configurar la respuesta ante fallo de alimentación como OFF/Standby, ON o Power Failure Auto. Para procesos exotérmicos, utilice el modo de Seguridad de Proceso para liberar la máxima refrigeración en caso de sobretemperatura en lugar de apagar.
Cualquier trabajo en el circuito de refrigerante debe ser realizado por contratistas aprobados en sistemas de refrigeración y aire acondicionado. El refrigerante es R-449A (A1, H280) con GWP 1397, sujeto a reporte de gases fluorados.
Selection & Integration Q&A
Elija el P010 para aplicaciones de alta caída de presión (designación P) y menor ruido (57 dB(A) frente a 63 dB(A)). La serie 015 ofrece mayor capacidad de refrigeración pero es más ruidosa; seleccione 015 si la capacidad es primordial y el ruido no es crítico.
La conexión de la bomba es macho G3/4, por lo que debe usar racores hembra G3/4. Asegúrese de que la caída de presión del circuito externo no exceda la curva de la bomba: el caudal cae a 6 l/min a 2,0 bar. El circuito debe ser cerrado externamente.
Instale solo en interiores, a 5–40 °C de ambiente, con iluminancia ≥300 lx y altitud ≤2000 m. Mantenga un espacio lateral de 50–200 cm. No instale en zonas ATEX. Accione las patas niveladoras o los frenos de estacionamiento antes de la operación.
Se debe proporcionar un enchufe de red en el sitio (cable incluido, enchufe no). El trabajo en el circuito de refrigerante requiere contratistas certificados. Para operación bajo cero, mezcle agua con glisantina o etilenglicol. Cierre el agua de refrigeración durante los tiempos de inactividad.