Peter Huber Kältemaschinenbau Unichiller P010w
Peter Huber Kältemaschinenbau Unichiller P010w — Enfriadores de recirculación.
El Unichiller P010w es un enfriador recirculante refrigerado por agua con bomba de plástico (tipo B) y controlador Pilot ONE, que cubre de -20 a +40 °C. Su designación 'P' lo distingue para circuitos externos cerrados con alta caída de presión. Proporciona hasta 1 kW de refrigeración a +15 °C, disminuyendo a 0,15 kW a -20 °C, para enfriamiento de procesos con agua de sitio a 5–20 °C.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Modelo | Nivel de ruido, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Unichiller P010w Actual | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller 015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller 015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 015w-H OLÉ | 54 | OLÉ | I / NFL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 017T | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017T-H | 64 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 017Tw-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020T | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020T-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller 020Tw | 60 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 020Tw-H | 60 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 022-H | 65 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 022w-H | — | Pilot ONE | III / FL | -10–100 | — | — |
| Unichiller 022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller 025T | 74 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025T-H | 74 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025Tw-H | — | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 230V 1~ 50Hz |
| Unichiller 025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller 025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller 025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P007 | 58 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007-H | — | Pilot ONE | III / FL | -20–100 | — | — |
| Unichiller P007-H OLÉ | 58 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P007 OLÉ | 58 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Unichiller P010 | 57 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P010-H | 57 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010-H OLÉ | 57 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P010 OLÉ | 57 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 50/60Hz |
| Unichiller P010w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 | 59 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208V 2~ 60Hz |
| Unichiller P012-H | 59 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012-H OLÉ | 59 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012 OLÉ | 59 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50/60Hz |
| Unichiller P012w-H OLÉ | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208V 2~ 60Hz |
| Unichiller P012w OLÉ | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Unichiller P015 | 63 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015-H | 63 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P015-H OLÉ | 63 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015 OLÉ | 63 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P015w | 54 | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 220-240V 1~/2~ 50Hz |
| Unichiller P015w-H | 54 | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P015w-H OLÉ | 54 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50Hz |
| Unichiller P022 | 65 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H | 65 | Pilot ONE | I / NFL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022-H OLÉ | 65 | OLÉ | I / NFL | -10–100 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P022 OLÉ | 65 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P022w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P022w-H | 60 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P022w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
| Unichiller P025 | 64 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H | 64 | Pilot ONE | III / FL | -10–100 | Ethernet, USB (Host u. D | 220-240V 1~ 50Hz |
| Unichiller P025-H OLÉ | 64 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025 OLÉ | 64 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w | 60 | Pilot ONE | I / NFL | -10–40 | Ethernet, USB (Host u. D | 208-230V 1~/2~ 60Hz |
| Unichiller P025w-H OLÉ | 60 | OLÉ | III / FL | -10–100 | USB (Device), RS232 Inte | 220-240V 1~ 50Hz |
| Unichiller P025w OLÉ | 60 | OLÉ | I / NFL | -10–40 | USB (Device), RS232 Inte | 208-230V 1~/2~ 60Hz |
Especificaciones completas
| Conexión de bomba | G3/4 AG male |
| Velocidad de bomba ajustable | no |
| Tipo de bomba | B |
| Conexión de sensor externo | Pt100 |
| Rango de temperatura | -20...40 °C |
| Peso | 57 kg |
| Alimentación | 220-240V 1~/2~ 50/60Hz |
| Controlador | Pilot ONE |
| Interfaz digital | Ethernet, USB (Host u. Device), RS232 |
| Límite de temperatura ambiente | 5...40 °C |
| Conexión de agua de refrigeración | G1/2 male |
| Presión diferencial del agua de refrigeración | 1 bar (min) |
| Presión del agua de refrigeración | 6 bar (max) |
| Clase de protección | IP20 |
| Clase de seguridad | I / NFL |
Descripción
Construcción y posicionamiento en la serie
- El P010w es un enfriador refrigerado por agua con bomba de plástico no ajustable (tipo B) y conexiones de bomba macho G3/4; el agua de refrigeración se conecta mediante roscas macho G1/2.
- Dentro de la línea Unichiller, la 'P' en el nombre del modelo denota idoneidad para aplicaciones que requieren altas caídas de presión, distinguiéndolo de modelos hermanos como las variantes Unichiller 015.
- La unidad está destinada exclusivamente a aplicaciones externas cerradas y no está protegida contra explosiones (no apta para instalación en zona ATEX).
Comportamiento térmico y medios
- La capacidad de refrigeración depende fuertemente de la temperatura: 1 kW a +15 °C, disminuyendo a 0,15 kW a -20 °C (a +20 °C ambiente).
- La bomba de plástico no es resistente a acetona ni a poliglicoles; para protección contra heladas, el agua debe mezclarse con glisantina o etilenglicol.
- La capacidad mínima de llenado es de 3,8 L con 1,7 L de volumen de expansión; el refrigerante es R-449A (A1, H280).
Instalación, control y operación
- El controlador Pilot ONE proporciona interfaces Ethernet, USB (host y dispositivo) y RS232, además de una conexión para sensor externo Pt100.
- La respuesta ante fallo de alimentación es configurable (OFF/Standby, ON, Power Failure Auto); el modo Process Safety libera la máxima refrigeración al activarse el disparo por sobretemperatura.
- La instalación requiere un espacio libre a la pared de 50–200 cm por cada lado, uso en interiores con ≥300 lx, y protección de las líneas eléctricas debajo de la unidad contra condensado.
Integration & Operating Notes
El suministro de agua de sitio debe proporcionar una presión diferencial de al menos 1 bar y no más de 6 bar. Una presión insuficiente impide el funcionamiento correcto, mientras que una presión excesiva puede dañar la unidad. Verifique el suministro antes de la instalación.
El suministro debe cumplir con ±5% de tensión con una tolerancia simultánea de ±2% de frecuencia. No se permiten desviaciones de signo opuesto (por ejemplo, alta tensión con baja frecuencia), ya que someten a esfuerzo el motor y la electrónica.
Los modelos de pie requieren un espacio libre a la pared de 50 a 200 cm por cada lado para permitir el acceso de mantenimiento. La unidad debe instalarse en interiores con una iluminancia de al menos 300 lx y hasta 2000 m de altitud.
Las líneas eléctricas directamente debajo de una unidad refrigerada por agua deben protegerse contra la entrada de líquido por condensación. Esta es una medida de instalación obligatoria para evitar el riesgo de descarga eléctrica.
El suministro de agua de refrigeración debe cerrarse incluso para tiempos de inactividad más cortos, como durante la noche, para prevenir daños por agua y corrosión durante los períodos de inactividad.
El Pilot ONE permite configurar la respuesta ante fallo de alimentación como OFF/Standby, ON o Power Failure Auto. Esto determina si el proceso se reinicia automáticamente después de un corte de energía, lo cual es crítico para la operación desatendida.
En el modo Process Safety, el controlador libera la máxima capacidad de refrigeración cuando se alcanza el valor de disparo de la protección contra sobretemperatura, en lugar de desconectar todos los polos. Esto es esencial para procesos exotérmicos donde cortar la refrigeración podría causar temperaturas descontroladas.
Los trabajos en el circuito de refrigerante solo deben ser realizados por contratistas aprobados de sistemas de refrigeración/aire acondicionado. El refrigerante R-449A se almacena bajo presión (H280).
Selection & Integration Q&A
Elija el P010w cuando su circuito de proceso tenga una alta caída de presión, como indica la 'P' en el nombre del modelo. Las variantes 015 son de propósito general; el P010w es específicamente adecuado para aplicaciones con alta caída de presión y ofrece un rango de -20 a +40 °C con hasta 1 kW de refrigeración a +15 °C.
El agua de refrigeración debe estar a 5–20 °C con una presión diferencial de 1–6 bar, conectada mediante roscas macho G1/2. Las conexiones de la bomba son macho G3/4; deben proporcionarse acoplamientos de manguera compatibles y no deben excederse los pares de apriete máximos.
La entrega base excluye el fluido de transferencia de calor; se requiere un mínimo de 3,8 L, con protección contra heladas usando glisantina o etilenglicol. El servicio del circuito de refrigerante debe ser realizado por contratistas aprobados. No se especifican intervalos de mantenimiento concretos en los documentos proporcionados.