Peter Huber Kältemaschinenbau Unimotive GL 30w
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unimotive GL 30w

Peter Huber Kältemaschinenbau Unimotive GL 30w — Temperature control units.

The Unimotive GL 30w is a water-cooled temperature control unit with a magnetically coupled stainless-steel pump, covering -45 to 95 °C with 24 kW heating and R-744 refrigerant. It is the largest of the Unimotive w-series, distinguished by 460 V 3~ 60 Hz supply and 57 A max current. It serves automotive temperature simulation and material testing with water-ethylene glycol mixtures.

Peter Huber Kältemaschinenbau Unimotive Series — Model Comparison & Selection

Model Display resolutionHeating capacity, WPower supplyPump connectionRefrigerantSafety class
Unimotive GL 30w Current 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive 10w 0.0112000400V 3~ 50HzM38x1,5 AG maleR-452A (A1, H280)III / FL
Unimotive 10w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 20w 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive 20w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 26w 0, 01 K24000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive 26w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 27w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive GL 07w 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 07w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 10w 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 10w-XT 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 20w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 20w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 50w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 50w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 60w 0, 0148000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 60w-XT 0, 0148000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Heating capacity 24 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable no
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -45...95 °C
Dimensions, Weight & Mechanical Design
Weight 820 kg
Electrical, Power & Drive Specifications
Current consumption 57 A (max)
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Refrigerant R-744 (A1, H280) (1st stage)
Maximum viscosity 200 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water consumption 3100 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

The Unimotive GL 30w is a water-cooled temperature control unit using R-744 (A1, H280) refrigerant in the first stage and a magnetically coupled, stainless-steel pump with fixed speed. It is the largest model in the Unimotive w-series, above the 10w and 20w siblings; the -XT variants are not part of this comparison. The unit weighs 820 kg and is rated IP20, safety class III / FL. Process connections are M38x1.5 male (bore shape Y, 60°, per DIN 3863), and cooling water connections are G3/4 male.

Working range and behavior under load

The temperature range is -45 to 95 °C with a display resolution of 0.01 K. Heating capacity is 24 kW. Cooling power falls from 35 kW at 0 °C to 8.5 kW at -40 °C, so low-temperature duty must be checked against the load curve. The unit is designed for water-ethylene glycol mixtures with corrosion protection (e.g. Glysantin®) down to -45 °C; maximum permissible kinematic viscosity is 200 mm²/s. Cooling water consumption is 3100 l/h at 15 °C water and 0 °C flow, and cooling power drops as cooling water temperature rises. Minimum filling capacity is 8.9 l, expansion tank 19.9 l, maximum system pressure 6 bar.

Control, installation and operation

The Pilot ONE controller with POKO ONE control output provides Ethernet, USB (Host and Device) and RS232 interfaces; an external Pt100 sensor can be connected. Electrical supply is 460 V 3~ 60 Hz with 57 A max current and 3x63 A fusing; three-phase devices below 63 A are delivered with cable but without plug. Leakage current exceeds 3.5 mA and external branch circuit protection per UL 489 is required. Voltage and frequency tolerances are ±5% and ±2% but may not be combined in the unfavorable direction. Cooling water must be 5–20 °C with differential pressure 1–4 bar and maximum pressure 6 bar; a backflow preventer on the building side is required, and sea water must not be used. Ambient temperature must be 5–40 °C. A drip tray must be installed below the unit, and minimum wall clearances depend on cooling type and bath configuration. The unit is Group 1 Class A per EN55011 and must not be installed in an ATEX zone.

Integration & Operating Notes

Electrical
Supply must be 460 V 3~ 60 Hz with 3x63 A fusing

The unit draws up to 57 A and requires 3x63 A branch protection. Three-phase devices below 63 A are delivered with cable but without plug, so a suitable plug and socket with protective earth must be provided on site. Leakage current exceeds 3.5 mA, and external branch circuit protection per UL 489 is mandatory.

Datasheet, Specifications; Operation Manual, Section Electrical Connection
Cooling & Media
Cooling water must stay within 5–20 °C and 1–4 bar differential

Cooling water intake temperature must be between 5 °C and 20 °C, with differential pressure between 1 bar and 4 bar and maximum pressure 6 bar. Consumption is 3100 l/h at 15 °C water and 0 °C flow. Only drinking water or filtered river/sea water may be used; sea water is prohibited. A backflow preventer on the building side is required, and cooling water should be shut off during downtimes because flow can occur even when the unit is switched off.

Datasheet, Specifications; Operation Manual, Section Cooling Water Connection
Process Limits
Fluid viscosity must not exceed 200 mm²/s

The maximum permissible kinematic viscosity of the heat transfer fluid is 200 mm²/s. At low temperatures viscosity rises and pump performance degrades, so the fluid selection and lowest operating temperature must be checked together. The unit is designed for water-ethylene glycol mixtures with corrosion protection down to -45 °C.

Datasheet, Specifications
Mounting
Install a drip tray and respect wall clearances

The responsible body must install a condensation water / heat transfer fluid drip tray below the unit. Minimum wall clearances depend on air- or water-cooling and on whether the unit runs with or without a bath; inadequate clearance prevents proper energy dissipation. The unit must not be installed or started inside an ATEX zone, and refrigerant charge versus room size must be checked.

Operation Manual, Section Installation
Process Limits
Bring fluid to room temperature before switching off

The heat transfer fluid must always be adjusted to room temperature before switching off to avoid overpressure in the system. For pressure-sensitive applications such as glass reactors, the maximum flow pressure of the unit must be taken into account and an external bypass may be required.

Operation Manual, Section Normal Operation
Electrical
Voltage and frequency tolerances may not combine unfavorably

Voltage tolerance is ±5% and frequency tolerance ±2%, but they may not be combined in the unfavorable direction (e.g. -5% voltage with +2% frequency is not allowed). The unit is a Group 1 Class A device per EN55011 for industrial EMC environments and may not be EMC-compatible elsewhere.

Datasheet, Specifications; Operation Manual, Section Installation

Selection & Integration Q&A

When should I choose the Unimotive GL 30w over the 10w or 20w siblings?

Choose the GL 30w when the load requires up to 24 kW heating and cooling down to -45 °C with 35 kW at 0 °C falling to 8.5 kW at -40 °C. The 10w and 20w are smaller; the GL 30w is the largest w-series unit and needs 460 V 3~ 60 Hz at 57 A.

What cooling water and electrical infrastructure must be provided for this unit?

Provide cooling water at 5–20 °C, 1–4 bar differential, max 6 bar, 3100 l/h at 15 °C water and 0 °C flow, with a building-side backflow preventer. Electrical: 460 V 3~ 60 Hz, 57 A max, 3x63 A fusing, UL 489 branch protection, PE socket; cable delivered without plug.

What maintenance and accessories are required beyond the base delivery?

The base delivery includes cable but no plug for three-phase below 63 A. On site you need a mating plug/socket with PE, a backflow preventer, a drip tray, and DIN 3863/3870 ball socket and sleeve nut for the M38x1.5 pump connections. Cooling water circuit materials include copper, 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water may be used.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unimotive GL 30w
Datasheet ·31,6 КБ ·2 pp.
View PDF
PDF
Unimotive Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF