Peter Huber Kältemaschinenbau Unistat T340 Dynamisches
Peter Huber Kältemaschinenbau Unistat T340 Dynamisches — Temperature control units.
The Unistat T340 Dynamisches is a closed, magnetically coupled stainless-steel circulation system with 48 kW heating and a 65–300 °C working range, distinguished within the Unistat series by its high heating capacity and 56 l expansion volume. It has no active refrigeration, so the 65 °C lower limit depends on application heat loss or water cooling. It serves high-temperature process thermostating in closed loops.
Peter Huber Kältemaschinenbau Unistate Bis 425C Series — Model Comparison & Selection
| Model | Display resolution | Power supply | Pump connection | Pump type | Temperature range, °C | Expansion volume, m³ |
|---|---|---|---|---|---|---|
| Unistat T340 Dynamisches Current | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Chili Dynamisches | 0.01 | 200-240V 1~/2~ 50/60Hz | M24x1,5 AG male | Pressure pump, variable | 65–300 | 0.002 |
| Unistat T305 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305 HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305w HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T320 Dynamisches | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T320w HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330w HT Dynamisches | 0, 01 K | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T340 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T350 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T402 Dynamisches | 0, 01 | 400V 3~N 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 80–425 | — |
| Unistat TR401 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 50–400 | 0.005 |
| Unistat TR402 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 80–425 | — |
Full specifications
| Alarm output | optic, acoustic, relay |
| Control output | POKO ONE (potential-free contact) |
| Expansion volume | 56 l |
| Heating capacity | 48 kW |
| Pump connection | M38x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | 65...300 °C |
| Weight | 373 kg (net) |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s (max. permissible) |
| Ambient temperature limit | 5...40 °C (permissible) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Closed circuit with magnetically coupled stainless-steel circulation pump; automatic switch-over and capacity adaptation for heating.
- 48 kW heating capacity and 56 l expansion volume set this modification apart from smaller siblings such as the Unistat T305 Dynamisches and T305 HT Dynamisches; the Chili Dynamisches is a different line.
- Pump connection M38x1.5 AG male with bore shape Y (60°) per DIN 3863; pump speed adjustable.
- Expansion tank is not thermoregulated and is lockable for open baths.
Thermal behavior and media
- Working range 65...300 °C. No active refrigeration: reaching 65 °C requires heat loss from the application or suitable water cooling.
- Air-cooled operation accepts heat loss between 0.1 kW and 2.8 kW depending on the unit; ambient must be well below 60 °C to reach 65 °C.
- Maximum permissible kinematic viscosity of the medium is 50 mm²/s.
- Adjustable overtemperature protection per DIN 12876; safety class III / FL.
Control, connection and operation
- Pilot ONE controller with POKO ONE potential-free contact output; display resolution 0.01 K; interfaces Ethernet, USB (Host and Device), RS232; external Pt100 sensor connection.
- Alarm output optic, acoustic and relay.
- Power supply 460 V 3~ 60 Hz; three-phase units below 63 A are supplied with cable but without plug, so a plug must be provided on site.
- Leakage current exceeds 3.5 mA, affecting protective earthing and RCD selection. Classification to EN55011: Class A, Group 1.
- Process Safety mode requires the compressor set to Permanently ON; Power Failure Auto resumes control after an outage if it was active.
Integration & Operating Notes
Because the unit has no active refrigeration, the minimum setpoint of 65 °C is only reachable when the application dissipates heat or suitable water cooling is provided. Size the cooling water circuit and plan heat dissipation before installation; for air-cooled operation the heat loss must lie between 0.1 kW and 2.8 kW and ambient must be well below 60 °C.
Three-phase devices drawing less than 63 A are delivered with cable but without a plug, so the installer must fit a suitable plug. Leakage current exceeds 3.5 mA, which governs protective earthing and residual current device selection. Supply tolerance is ±5% voltage with ±2% frequency, and the combination of -5% voltage with +2% frequency is not allowed.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage to the application. For externally open applications the expansion vessel must be locked to prevent fluid loss. Verify the setting during commissioning according to the actual circuit type.
When Process Safety mode is used to protect against exothermic reactions, the compressor must be configured to Permanently ON so cooling remains active at the overtemperature trigger. Power Failure Auto resumes temperature control automatically after an outage if it was active, which affects unattended operation risk assessment.
Selection & Integration Q&A
Pick the T340 when the process needs the 48 kW heating capacity and 56 l expansion volume for large or high-load closed circuits in the 65–300 °C range. Smaller siblings suit lower heat demand; the Chili Dynamisches is a different line.
Match pipework or flexible hoses to the M38x1.5 male pump connection with bore shape Y (60°) per DIN 3863. Provide a plug on site for the 460 V 3~ 60 Hz supply, and plan water cooling or sufficient application heat loss to reach 65 °C.
Install level with parking brakes or leveling feet set, outside any ATEX zone, and allow about 2 hours acclimation after a temperature change before power-on. Power Failure Auto can resume control after an outage, so assess unattended risk accordingly.
Periodically inspect and replace hoses and hose connections, and shut off cooling water during downtimes. The unit ships with cable but no plug for three-phase supply below 63 A; the plug, cooling water hookup and thermal fluid are not part of base delivery.