Agilent Technologies 1260 Infinity II Preparative LC System | UV based Prep HPLC
Agilent Technologies 1260 Infinity II Preparative LC System | UV based Prep HPLC — Liquid chromatography with Motor power 0.103 kW.
The 1260 Infinity II Preparative LC System is a UV-based preparative HPLC platform built around the G7157A preparative autosampler, which injects 0.1–900 µL at up to 400 bar. It is the UV-detection preparative configuration of the 1260 Infinity II series, distinguished from the manual preparative and analytical-scale purification siblings by automated high-volume injection. It serves as the injection and separation front end of a preparative purification train feeding fraction collection.
Agilent Technologies Preparative HPLC Systems Series — Model Comparison & Selection
Full specifications
| Motor power | 350 BTU/h |
| Carryover | 0.005 percent |
| Column temperature | 4 °C |
| Maximum operating pressure | 400 bar |
| Plate Count | 40606 Nth/meter |
| Retention Time | 15.18 min |
| Sample Capacity | 132 vial |
| Typical Flow Rate | 1 mL/min |
| Productivity range mfr | Micrograms Micrograms |
| Asymmetry mfr | 1.27 |
| Injection volume range mfr | 0.1...900 μL |
| Maximum draw volume per step mfr | 100 μL |
| Sample Cooler Function Test duration mfr | 15 min |
| Bench clearance side mfr | 2.5 cm |
| Bench clearance rear mfr | 8 cm |
| IP address: mfr | 192.168.254.11 |
| Subnet Mask: mfr | 255.255.255.0 |
| Default Gateway mfr | not specified specified |
| ? mfr | displays syntax and descriptions of commands com |
| ip <x.x.x.x> mfr | sets new ip address address |
| sm <x.x.x.x> mfr | sets new subnet mask mask |
| gw <x.x.x.x> mfr | sets new default gateway gateway |
| exit mfr | exits shell and saves all changes changes |
| Settable injection range mfr | 0.1...900 extension |
| Injection precision mfr | 500...3600 |
| Injection cycle time mfr | 60 μL |
| Communications mfr | Controller-area network , Local Area Network ERI |
| Housing mfr | All materials recyclable. recyclable. |
| Safety standards: mfr | IEC, EN, CSA, UL UL |
| ISM Classification mfr | 1 B |
| Column Inner Diameter | 1...3 in |
| Weight | 6 kg |
| Dimensions (height × width × depth) mfr | 205 mm |
| Dimensions (height x width x depth) mfr | 205 mm |
| Current | 10 max. |
| Power supply | 24 VDC |
| Sample thermostat heater resistance acceptance range mfr | 5...9 Ohm |
| Line voltage mfr | 100...240 |
| Line frequency mfr | 50 |
| Sample viscosity range mfr | 0.2...5 cP |
| Refrigerant gas mfr | 600 a |
| Operating Altitude | 3000 m |
| Sample Cooler Function Test final stability mfr | 1.0 °C |
| Humidity mfr | 95 °C |
| Non-operating altitude mfr | 4600 m |
| Safety standards: IEC, EN, CSA, UL mfr | 2 |
Description
Construction and positioning
- The system is a UV-detection preparative LC configuration; its injection module is the G7157A preparative autosampler with a 0.1–900 µL injection head rated to 400 bar.
- Within the 1260 Infinity II purification family it sits above the Manual Preparative LC System (no automated sampler) and is distinct from the Analytical-Scale Purification Systems (1220/1260/1260 Bio-Inert), which are not preparative-load instruments.
- The autosampler transport uses four closed-loop stepper motors (X, Z, Theta, Gripper) with optical encoders that automatically correct position errors, e.g. after accidental movement during vial loading.
- The injection valve is a two-position 6-port valve wired on five ports; port 3 is unused and not available for connections.
Behavior and media
- Injection volume is selectable from 0.1 to 900 µL; a single Draw step command is limited to 100 µL, so larger volumes require multiple draw steps with Plunger Home resets.
- The metering device is flushed after every injection to keep carry-over minimal; flush solvent supply must therefore be provided.
- Mobile phase compatibility is constrained by the leak sensor: DMF corrodes the PVDF sensor and must not be used.
- Reported performance data include 40,606 N/m and asymmetry 1.27; these are method/column-dependent values, not guaranteed instrument ratings.
Installation, control and operation
- The module must sit horizontally, checked with a bubble level, particularly when a Sample Cooler or Sample Thermostat is fitted.
- Clearances: 2.5 cm on either side and about 8 cm at the rear for air circulation and electrical connections.
- LAN/TCP/IP configuration is set via the 6-bit configuration switch and initialization mode (DHCP or manual), with PC/ChemStation setup described in the manual.
- Early Maintenance Feedback (EMF) tracks wear; maintenance positions and step commands allow Change Needle, Change Metering Seal/Piston, Park Arm, Change Gripper and Automatic Referencing procedures.
Integration & Operating Notes
The G7157A injection head is rated to 400 bar; column back pressure plus plumbing restriction must stay under this figure, otherwise the sampling sequence can fail or the metering device can be damaged. Size columns and flow rates so the preparative load does not push the head past its rating.
Dimethylformamide attacks the PVDF leak sensor and causes corrosion. If DMF is required by the method, the leak sensor must be treated as a consumable and inspected regularly, or the method moved to a compatible solvent.
A Draw step command cannot exceed 100 µL. For injections up to the 900 µL head volume, the method must chain multiple draw steps and return the plunger home between them; otherwise the sampler aborts the step and reports an error.
Corrected gripper positions are stored in firmware, so after repair of internal components the Calibration Tool Kit G7129-60014 must be used with the four tray reference points; the Gripper Verification Test (positions 1, 11, 39, 56, 66, 101, 111, 139, 156, 166) confirms alignment.
The arm must be moved to Park Arm and Transport Protection Foam G7129-40050 fitted before transport; shipping without both risks mechanical damage to the transport assembly and requires re-referencing on arrival.
Selection & Integration Q&A
Pick this system when automated injection of 0.1–900 µL at up to 400 bar and UV-directed fraction collection are needed. The Manual Preparative system lacks the automated G7157A sampler; the 1220/1260 Analytical-Scale Purification systems are for analytical loads, not preparative injection volumes.
A pump and column capable of staying within the 400 bar head rating, flush solvent for the post-injection metering-device flush, and waste disposal via the recommended 6 L can with Stay Safe cap GL45 4-port (5043-1221). The injection valve uses five of six ports; port 3 is not connectable.
Plan for Calibration Tool Kit G7129-60014 for Automatic Referencing, Transport Protection Foam G7129-40050 for shipping, and Lab Advisor B.02.11+ (heater resistance test) or 2.19+ (Sample Cooler Function Test) if a Sample Cooler/Thermostat is fitted. EMF tracks wear; maintenance positions cover needle, metering seal/piston and gripper changes.
Dimensional Drawings & Technical Documentation
Dimensional drawings
Click drawing to inspect vector dimensions