Peter Huber Kältemaschinenbau Unimotive GL 20w
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unimotive GL 20w

Peter Huber Kältemaschinenbau Unimotive GL 20w — Temperature control units.

The Unimotive GL 20w is a water-cooled temperature control unit with a magnetically coupled stainless-steel pump, covering -45 to 95 °C with 24 kW heating. It is the GL modification of the 20w series, intended for water-ethylene glycol mixtures with corrosion protection down to -45 °C. It serves automotive test benches and processes requiring precise temperature control with plant cooling water.

Peter Huber Kältemaschinenbau Unimotive Series — Model Comparison & Selection

Model Display resolutionHeating capacity, WPower supplyPump connectionRefrigerantSafety class
Unimotive GL 20w Current 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive 10w 0.0112000400V 3~ 50HzM38x1,5 AG maleR-452A (A1, H280)III / FL
Unimotive 10w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 20w 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive 20w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 26w 0, 01 K24000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive 26w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)I / NFL
Unimotive 27w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-452A (A1, H280)III / FL
Unimotive GL 07w 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 07w-XT 0, 0112000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 10w 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 10w-XT 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 20w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 30w 0, 0124000460V 3~ 60HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 50w 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 50w-XT 0, 0124000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL
Unimotive GL 60w 0, 0148000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)III / FL
Unimotive GL 60w-XT 0, 0148000400V 3~ 50HzM38x1, 5 AG maleR-744 (A1, H280)I / NFL

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Heating capacity 24 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable no
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -45...95 °C
Dimensions, Weight & Mechanical Design
Weight 612 kg
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Refrigerant R-744 (A1, H280) (1st stage)
Maximum viscosity 200 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water consumption 2100 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

The Unimotive GL 20w is a water-cooled temperature control unit in the Unimotive series, distinguished from sibling models (10w, 10w-XT, 20w, 20w-XT) by its GL designation and 20w size class. It uses a magnetically coupled stainless-steel pump with fixed speed (not adjustable) and M38x1.5 male pump connections. The refrigerant is R-744 (CO2) in the first stage, with a charge of 3.5 kg and GWP 1. The unit weighs 612 kg and has IP20 protection.

Working range and media

Control and operation

The unit is equipped with the Pilot ONE controller and POKO ONE control output. Interfaces include Ethernet, USB (Host and Device), and RS232. An external Pt100 sensor can be connected. The pump speed is not adjustable. The unit requires a 400 V 3~ 50 Hz supply with maximum current 55.7 A and 3x63 A fusing. Three-phase devices below 63 A are supplied with cable but without a plug. Leakage current exceeds 3.5 mA, requiring appropriate protective earthing. The unit is a Group 1 Class A device per EN55011, suitable for industrial EMC environments only.

Installation and site requirements

Ambient temperature must be 5–40 °C. The unit must not be installed in an ATEX zone. A drip tray for condensate/heat transfer fluid must be installed below the unit. Minimum wall clearances depend on cooling type and operation with or without a bath. Cooling water must be drinking water or filtered river water (sea water prohibited), with a backflow preventer on the building side. Cooling water supply should be shut off during downtimes. Outdoor installation requires frost-protected lines and cooling water temperature not below 5 °C. Power cables are length-limited to 4 m for 3-phase connections. Pressure-sensitive applications (e.g., glass reactors) must account for maximum flow pressure and may need an external bypass. Heat transfer fluid must be brought to room temperature before switching off to avoid overpressure.

Integration & Operating Notes

Process Limits
Cooling water temperature must stay between 5 and 20 °C

Exceeding 20 °C reduces cooling capacity and may require higher flow rates; below 5 °C risks frost damage. The datasheet specifies this intake range, and the manual prohibits cooling water below 5 °C for outdoor installation. Plan the plant cooling water supply accordingly.

Datasheet, page 2; Operation Manual, page 28
Electrical
Leakage current exceeds 3.5 mA – verify PE and RCD selection

The unit's leakage current is above 3.5 mA, which affects protective earthing design and residual current device selection. Ensure the installation provides a reliable protective earth connection and that any RCD is rated for high leakage currents to avoid nuisance tripping.

Datasheet, page 2
Electrical
Three-phase supply requires 3x63 A fusing and cable without plug

The unit draws up to 55.7 A at 400 V 3~ 50 Hz and must be protected with 3x63 A fuses. Three-phase devices below 63 A are delivered with a cable but without a plug, so site wiring must include a suitable connector or hardwired connection by a certified electrician.

Datasheet, page 2; Operation Manual, page 31
Mounting
Install a drip tray below the unit for condensate and fluid

The responsible body must install a condensation water / heat transfer fluid drip tray below the temperature control unit to contain leaks or condensate. This is mandatory to prevent damage to the floor and surroundings, especially when operating at low temperatures where condensation occurs.

Operation Manual, page 15
Process Limits
Use only water-ethylene glycol mixture with corrosion protection

The unit is constructed for operation with water-ethylene glycol mixture including corrosion protection (e.g., Glysantin®) down to -45 °C. Using other fluids may cause corrosion, fouling, or inadequate performance. Minimum filling capacity is 8.9 l, and expansion tank capacity is 19.9 l.

Datasheet, page 1 and page 2
Maintenance
Shut off cooling water during downtimes to prevent flow

Cooling water can flow through the unit even when switched off, so shut off the supply during shorter downtimes (e.g., overnight) to prevent unnecessary water consumption and potential water damage. Also, bring heat transfer fluid to room temperature before switching off to avoid overpressure.

Operation Manual, page 28 and page 34
Control & I/O
Interfaces include Ethernet, USB, and RS232 for remote control

The Pilot ONE controller provides Ethernet, USB (Host and Device), and RS232 interfaces, allowing integration into automation systems. An external Pt100 sensor can be connected for precise temperature measurement at the application. Ensure cabling and network configuration meet industrial EMC requirements (Group 1 Class A).

Datasheet, page 2; Operation Manual, page 25

Selection & Integration Q&A

When should I choose the Unimotive GL 20w over the 20w or 10w variants?

Choose the GL 20w when you need water-ethylene glycol operation down to -45 °C with 24 kW heating and water cooling. The 20w is air-cooled; the 10w has lower capacity. The GL 20w is specifically built for glycol mixtures with corrosion protection, making it suitable for automotive test fluids.

What are the requirements for the cooling water supply and connections?

Cooling water connection is G3/4 male. Supply must be 5–20 °C, differential pressure 1–4 bar, max 6 bar, flow 2100 l/h at 15 °C. Use drinking or filtered river water (no sea water), install a backflow preventer, and provide a drip tray. Shut off water during downtimes.

What maintenance and accessories are required that are not included in base delivery?

The unit is delivered with cable but without a plug for 3-phase. A drip tray and backflow preventer are site-provided. Heat transfer fluid (water-glycol mixture) must be supplied separately; min filling 8.9 l. Regular maintenance includes checking cooling water quality and shutting off water during downtimes.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unimotive GL 20w
Datasheet ·97,0 КБ ·2 pp.
View PDF
PDF
Unimotive Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF