Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat T345 HT Dynamisches

Peter Huber Kältemaschinenbau Unistat T345 HT Dynamisches — Temperature control units.

The Unistat T345 HT Dynamisches is a high-temperature dynamic temperature control system with a 65–300 °C working range, 72 kW heating and 300 kW cooling at 30 °C. It is the larger-capacity HT modification in the Unistat T3xx series, positioned above the T305 variants. It serves closed-loop heating and cooling of large process loads requiring precise, dynamic temperature control up to 300 °C.

Peter Huber Kältemaschinenbau Unistate Bis 425C Series — Model Comparison & Selection

Model Display resolutionPower supplyPump connectionPump typeTemperature range, °CExpansion volume, m³
Unistat T345 HT Dynamisches Current 0, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st65–3000.056
Chili Dynamisches 0.01200-240V 1~/2~ 50/60HzM24x1,5 AG malePressure pump, variable 65–3000.002
Unistat T305 Dynamisches 0, 01200-240V 1~/2~ 50/60HzM24x1, 5 AG malePressure pump, variable 65–300—
Unistat T305 HT Dynamisches 0, 01200-240V 1~/2~ 50/60HzM24x1, 5 AG malePressure pump, variable 65–300—
Unistat T305w HT Dynamisches 0, 01200-240V 1~/2~ 50/60HzM24x1, 5 AG malePressure pump, variable 65–300—
Unistat T320 Dynamisches 0, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st65–3000.024
Unistat T320w HT Dynamisches 0, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st65–3000.024
Unistat T330 HT Dynamisches 0, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st65–3000.024
Unistat T330w HT Dynamisches 0, 01 K400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st65–3000.024
Unistat T340 Dynamisches 0, 01460V 3~ 60HzM38x1, 5 AG malemagnetically coupled, st65–3000.056
Unistat T340 HT Dynamisches 0, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st65–3000.056
Unistat T345 Dynamisches 0, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st65–3000.056
Unistat T350 HT Dynamisches 0, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st65–3000.056
Unistat T402 Dynamisches 0, 01400V 3~N 50/60HzM24x1, 5 AG malePressure pump, variable 80–425—
Unistat TR401 Dynamisches 0, 01200-240V 1~/2~ 50/60HzM24x1, 5 (Flow) M24x1, 5Pressure pump, variable 50–4000.005
Unistat TR402 Dynamisches 0, 01200-240V 1~/2~ 50/60HzM24x1, 5 (Flow) M24x1, 5Pressure pump, variable 80–425—

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Expansion volume 56 l
Heating capacity 72 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range 65...300 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 300 kW (at 30 °C)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Working range and media behavior

Control, installation and operation

Integration & Operating Notes

Electrical
Three-phase supply must meet combined voltage/frequency tolerance

The unit requires 400 V 3~ 50 Hz with ±5% voltage and ±2% frequency tolerance, but these tolerances must not be applied simultaneously in opposite directions. Verify supply quality before commissioning; three-phase devices under 63 A are delivered with cable but without a plug, so the site plug must be provided and fitted by an electrician.

Unistat T345 HT Technical Data, page 2
Process Limits
Expansion vessel lock state depends on open vs closed application

For externally closed applications the expansion vessel must remain unlocked; locking it will damage the application due to overpressure. For externally open applications the expansion vessel must be locked to prevent fluid loss. Confirm the application type before commissioning.

Unistat Operation Manual, page 33
Process Limits
Fluid viscosity must stay below 50 mm²/s at operating temperature

The maximum permissible kinematic viscosity is 50 mm²/s. Select the heat transfer fluid so that its viscosity at the lowest operating temperature remains within this limit; otherwise pump load rises and circulation may become inadequate.

Unistat T345 HT Technical Data, page 1
Mounting
Transport and store upright only; drain before moving

The unit must be transported and stored upright only; horizontal transport damages the compressor. Only an emptied unit may be moved, since filled transport risks thermal fluid overflow. Casters are not suitable for transport and carry only 25% of total mass symmetrically; use an industrial truck.

Unistat Operation Manual, page 22
Control & I/O
Process Safety mode requires compressor set to Permanently ON

If Process Safety mode is used to protect against exothermic reactions, the compressor must be configured to Permanently ON so that cooling remains active when the overtemperature trigger occurs. Power Failure Auto resumes temperature control automatically after a power outage if it was active.

Unistat Operation Manual, pages 19–20
Maintenance
Shut off cooling water even for overnight downtime

Shut off the cooling water supply to the unit even for shorter downtimes such as overnight, to prevent water damage and unnecessary load on the cooling water circuit. Periodically check hoses and connections for leaks and quality and replace as required.

Unistat Operation Manual, page 29

Selection & Integration Q&A

When should I choose the Unistat T345 HT Dynamisches instead of the T305 HT or T305w HT siblings?

Choose the T345 HT when the process needs the larger 72 kW heating and 300 kW cooling capacity at 30 °C and a 65–300 °C range. The T305/T305w HT are smaller-capacity siblings; select them only if their lower capacity covers the load.

What mating fittings and external circuit conditions must the pump loop satisfy?

Pump connections are M38x1.5 male with bore shape Y (60°) per DIN 3863; hoses need ball sockets per DIN 3863 and sleeve nuts per DIN 3870. External pressure drop must be checked against the pump curve of up to 200 l/min at 5.5 bar.

What installation environment and duty-cycle limits apply from the manual?

Install indoors within 5–40 °C ambient, IP20 enclosure, never inside an ATEX zone. Transport and store upright only, level the unit and engage parking brakes before operation, and allow 2 h acclimation after a temperature change before power-on.

What maintenance and delivery-scope items should be planned beyond the base unit?

The unit ships with cable but without a plug for three-phase supplies under 63 A; the site must provide the plug. Plan periodic hose/connection inspection and replacement, shut off cooling water during downtime, and provide heat transfer fluid within the 50 mm²/s viscosity limit.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat T345 HT Technical Data
Datasheet ·17,6 КБ ·2 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.