Peter Huber Kältemaschinenbau Unistat TR401 Dynamisches
Peter Huber Kältemaschinenbau Unistat TR401 Dynamisches — Temperature control units.
The Unistat TR401 Dynamisches is a water-cooled, pressure-pump temperature control unit with a split Pilot ONE controller, covering 50 to 400 °C. It is the TR401 controller variant of the Unistat TR series, distinguished from TR400/TR402 siblings by its separate HT-Circulator and Controller connection. It serves high-temperature process loops requiring dynamic, variable-speed circulation.
Peter Huber Kältemaschinenbau Unistate Bis 425C Series — Model Comparison & Selection
| Model | Display resolution | Power supply | Pump connection | Pump type | Temperature range, °C | Expansion volume, m³ |
|---|---|---|---|---|---|---|
| Unistat TR401 Dynamisches Current | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 50–400 | 0.005 |
| Chili Dynamisches | 0.01 | 200-240V 1~/2~ 50/60Hz | M24x1,5 AG male | Pressure pump, variable | 65–300 | 0.002 |
| Unistat T305 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305 HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305w HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T320 Dynamisches | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T320w HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330w HT Dynamisches | 0, 01 K | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T340 Dynamisches | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T340 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T350 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T402 Dynamisches | 0, 01 | 400V 3~N 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 80–425 | — |
| Unistat TR402 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 80–425 | — |
Full specifications
| Control output | POKO ONE (potential-free contact) |
| Expansion volume | 5 l |
| Pump connection | M24x1, 5 (Flow) M24x1, 5 (Return) |
| Pump speed adjustable | Yes |
| Pump type | Pressure pump, variable speed |
| External sensor connection | Pt100 |
| Temperature range | 50...400 °C |
| Weight | 55 kg (net) |
| Current consumption | 14 A (max) |
| Fuse rating | 16 A |
| Power supply | 200-240V 1~/2~ 50/60Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Split architecture: HT-Circulator and Controller are separate assemblies connected by a cable of approximately 5 m, specific to the TR401/TR402 variants; the TR400 sibling does not use this controller connection.
- Variable-speed pressure pump with M24x1.5 flow and return connections; cooling water circuit via G1/2 male thread.
- Net weight 55 kg, IP20 enclosure, Pilot ONE controller with POKO ONE potential-free alarm contact.
- Safety classification III / FL with adjustable overtemperature protection to DIN 12876.
Working range and behavior
- Working temperature range 50...400 °C; ambient installation window 5...40 °C.
- Low-level protection uses a pressure sensor in the fluid circuit: air from insufficient filling or venting prevents the required pressure from being reached and interrupts temperature control and circulation.
- Process Safety mode keeps cooling active at the OT trigger only if the compressor is set to Permanently ON.
- Avoid recurring, very dynamic high-temperature changes in short intervals; the guarantee expires under such cyclic thermal loading of the plate heat exchanger.
Installation, connection and control
- Supply 200–240 V, 1~ or 2~, 50/60 Hz, max current 14 A, 16 A fuse; external branch circuit protection to UL 489 required; hard-wired connection by an electrician.
- At 230 V the maximum current is just below 16 A and can be limited to 13 A or 10 A at first start-up.
- Interfaces: Ethernet, USB host and device, RS232; external Pt100 sensor connection; display resolution 0.01 K.
- Expansion vessel must remain unlocked for externally closed applications and locked for externally open applications.
Integration & Operating Notes
The ±10 % voltage tolerance applies only as long as the frequency tolerance does not run in the opposite direction. Verify site supply quality before connection, since a combined deviation outside this envelope can damage the unit.
The equipment requires external branch circuit protection according to UL 489. Size the upstream breaker for the 14 A maximum current and 16 A fuse rating, and have hard-wired connection performed by an electrician.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage. For externally open applications it must be locked to prevent fluid loss. Confirm the application type before commissioning.
Low-level protection relies on a pressure sensor in the fluid circuit. Insufficient fill level or inadequate venting prevents the specified pressure from being reached, interrupting temperature control and circulation. Fill and vent thoroughly before starting.
Transport and store the unit upright only; horizontal transport damages the compressor. Allow about 2 hours acclimation when moving between cold and warm environments before switching on. Activate leveling feet and parking brakes before commissioning.
Close the cooling water supply even for short downtimes such as overnight to prevent water damage and unnecessary load on the cooling water circuit. Periodically check hoses and connections for leaks and quality and replace as required.
Process Safety mode keeps cooling active at the overtemperature trigger only if the compressor is configured to Permanently ON via System Settings > Power/ECO Settings. Configure this before relying on the mode for exothermic process protection.
The Pilot ONE controller connects to the machine by a cable of approximately 5 m. Plan the control cabinet or operator station position within this distance, and note that controller connection applies specifically to TR401 and TR402 variants.
Selection & Integration Q&A
Choose TR401 when a split HT-Circulator and Controller arrangement with a roughly 5 m controller cable is required. TR400 does not use this controller connection; TR402 is a separate controller variant. Confirm the controller variant against the process layout before ordering.
Provide 200–240 V, 1~ or 2~, 50/60 Hz with max 14 A and a 16 A fuse, plus external branch circuit protection to UL 489. At 230 V the current is just below 16 A and can be limited to 13 A or 10 A at first start-up. Hard-wiring must be done by an electrician.
Install indoors at 5...40 °C ambient with IP20 protection, on a level surface with leveling feet and parking brakes engaged. Do not install in an ATEX zone without an Ex px cabinet. Avoid recurring very dynamic high-temperature changes in short intervals; the guarantee expires under such cyclic loading.
Base delivery includes a power cable with country-specific plug (specify at order). Plan for M24x1.5 process hoses and G1/2 cooling water fittings, a drip tray below the unit, periodic hose inspection and replacement, and cleaning of the hat-type strainer on water-cooled units.