Peter Huber Kältemaschinenbau CC-508w Kälte-Badumwälzthermostat
Peter Huber Kältemaschinenbau CC-508w Kälte-Badumwälzthermostat — Thermostatic baths with Noise level 57 dB.
The CC-508w is a water-cooled circulating bath thermostat with a 5 L bath and a variable-speed pressure/suction pump, covering -55 to 200 °C with ±0.02 K stability. It is the 5 L water-cooled variant in the CC series, distinguished from air-cooled siblings by its 5–20 °C cooling water requirement. It serves as a temperature-control source for external circuits via M16x1 connections.
Direct drop-in replacements
Peter Huber Kältemaschinenbau Cc Modelle Bis 90C Series — Model Comparison & Selection
| Model | Noise level, dB | Power supply | Pump connection | Temperature range, °C | Weight, kg | Filling volume, m³ |
|---|---|---|---|---|---|---|
| CC-508w Kälte-Badumwälzthermostat Current | 57 | 208-230V 1~/2~ 60Hz | M16x1 AG male | -55–200 | — | 0.004 |
| CC-410wl Kälte-Badumwälzthermostat | — | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | -45–200 | 71 | 0.017 |
| CC-415wl Kälte-Badumwälzthermostat | — | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | -40–200 | 61 | 0.004 |
| CC-510w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -50–200 | 106 | 0.016 |
| CC-515w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -55–200 | 105 | 0.016 |
| CC-520w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -55–200 | 161 | 0.015 |
| CC-525w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -55–200 | 163 | 0.015 |
| CC-905 Kälte-Badumwälzthermostat | 64 | 400V 3~N 50Hz | M16x1 AG male | -90–200 | 171 | 0.019 |
| CC-905w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -90–200 | 175 | 0.019 |
| CC-906w Kälte-Badumwälzthermostat | — | 460V 3~ 60Hz | M16x1 AG male | -90–200 | 234 | 0.025 |
| CC-K12 Kälte-Badthermostat | — | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -20–200 | 29 | 0.007 |
| CC-K15 Kälte-Badthermostat | — | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -20–200 | 28 | — |
| CC-K20 Kälte-Badthermostat | 50 | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -30–200 | 41 | 0.012 |
| CC-K25 Kälte-Badthermostat | 50 | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -30–200 | 41 | 0.017 |
| CC-K6 Kälte-Badumwälzthermostat | 57 | 208-240V 1~/2~ 50/60Hz | M16x1 AG male | -25–200 | 25 | — |
| Variostat Kältethermostat für variable Badgefäße | 54 | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | -30–150 | 25 | — |
Full specifications
| Noise level | 57 dB(A) |
| Bath volume | 5 l |
| Filling volume | 4 l (min) |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | Yes |
| Pump type | Pressure and suction pump, variable speed |
| External sensor connection | Pt100 |
| Temperature range | -55...200 °C |
| Temperature stability mfr | ±0, 02 K |
| Dimensions (W x D x H) mfr | 410 x 480 x 764 mm |
| Heating capacity mfr | 2, 45 kW |
| Delivery capacity pressure pump max. mfr | 25 l/min; 0, 7 bar |
| Delivery capacity suction pump max. mfr | 18, 5 l/min; 0, 4 bar |
| Bath opening WxD/BD mfr | 120 x 110 / 160 mm |
| Power supply | 208-230V 1~/2~ 60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Cooling capacity mfr | 100:1, 5; 20:1, 5; 0:1, 5; -20:0, 8; -40:0, 25 k (at °C bath temperature) |
| Safety class | III / FL |
Description
Construction and series positioning
The CC-508w is a refrigerated circulating bath (Kälte-Badumwälzthermostat) with a 5 L bath volume and a minimum filling volume of 4 L. It is water-cooled, requiring a cooling water supply at 5–20 °C, which differentiates it from air-cooled siblings such as the CC-405w, CC-410wl, CC-415wl and CC-505wl. The bath opening measures 120 x 110 mm (W x D) with a 160 mm depth. The unit uses the Pilot ONE controller and is rated IP20, safety class III/FL.
Thermal and hydraulic behavior
- Temperature range: -55 to 200 °C; stability ±0.02 K.
- Heating capacity: 2.45 kW.
- Cooling capacity at bath temperature: 1.5 kW at 100 °C, 1.5 kW at 20 °C, 1.5 kW at 0 °C, 0.8 kW at -20 °C, 0.25 kW at -40 °C.
- Pump: variable-speed pressure and suction pump; max delivery pressure side 25 l/min at 0.7 bar; suction side 18.5 l/min at 0.4 bar.
- Pump connections: M16x1 male.
- Maximum permissible kinematic viscosity of the medium: 50 mm²/s.
Installation, control and operation
- Power supply: 208–230 V, 1~/2~, 60 Hz. Voltage tolerance ±5% only with simultaneous frequency tolerance ±2%; the combination -5% voltage with +2% frequency is not allowed.
- Single- and two-phase devices are delivered with a power cable and country-specific plug, to be specified at ordering.
- Interfaces: Ethernet, USB (host and device), RS232; external Pt100 sensor connection.
- Cooling water circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM; only compatible water may be used. If cooling water temperature falls below the condensation point, internal cooling water pipes must be insulated.
- Refrigerant: R-1270 (A3, H220), GWP 0; flammable refrigerant requires appropriate safety measures.
- EMC classification: EN55011 Class A, Group 1.
- Permissible ambient temperature: 5–40 °C; IP20 requires a dry environment protected from water ingress.
Integration & Operating Notes
Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%; the combination of -5% voltage with +2% frequency is explicitly not allowed. Verify site supply quality against these combined limits before commissioning to avoid invalid operating conditions. The unit is supplied for 208–230 V, 1~/2~, 60 Hz.
IP20 protection does not guard against water ingress, so the installation site must be dry and protected from splashes. The permissible ambient temperature range is 5–40 °C; operating outside this range can affect performance, reliability and safety. Plan the location with these environmental limits in mind.
The maximum permissible kinematic viscosity of the circulated medium is 50 mm²/s. Higher-viscosity fluids can overload the pump and reduce circulation performance. Select the bath fluid and external circuit medium accordingly, especially at low temperatures where viscosity increases.
Single- and two-phase devices (100–240 V) are delivered with a power cable and a country-specific plug, which must be specified when ordering. Three-phase devices below 63 A are supplied with cable but without plug, so a suitable plug must be provided on site. Confirm the plug type against the site outlet before order.
The refrigerant is R-1270 with safety group A3 and GHS H220, meaning it is flammable. This affects ventilation requirements, handling procedures and the site safety assessment. The Global Warming Potential is 0, which supports environmental compliance but does not remove the flammability classification.
The Pilot ONE controller provides Ethernet, USB (host and device) and RS232 interfaces, plus an external Pt100 sensor connection. These allow remote monitoring and control or connection to a external temperature sensor for controlling the external circuit. Plan cabling and network access accordingly.
Selection & Integration Q&A
Choose the CC-508w when a 5–20 °C cooling water supply is available and higher cooling capacity at low temperatures is needed; it is water-cooled and reaches -55 °C. Air-cooled siblings like the CC-405w avoid water connections but may have different capacity or temperature limits; verify their datasheets for your duty point.
The pump connections are M16x1 male, so hoses and fittings must match this thread. The pump is a variable-speed pressure and suction type, with max delivery 25 l/min at 0.7 bar on the pressure side and 18.5 l/min at 0.4 bar on the suction side. Ensure the medium viscosity does not exceed 50 mm²/s.
Install in a dry, splash-free location with ambient temperature between 5 and 40 °C. IP20 protection requires protection from water ingress. The unit is water-cooled and needs a cooling water supply at 5–20 °C; if water temperature falls below the condensation point, insulate internal cooling water pipes.
The base delivery includes a power cable with country-specific plug for single/two-phase units (plug type must be specified at order). Cooling water connections and hoses are not included; provide M16x1 mating fittings. No maintenance schedule is given in the datasheet; follow the manual for service intervals. Refrigerant R-1270 (A3) requires appropriate handling.