Peter Huber Kältemaschinenbau CC-415wl Kälte-Badumwälzthermostat
Peter Huber Kältemaschinenbau CC-415wl Kälte-Badumwälzthermostat — Thermostatic baths.
The CC-415wl is a 5-litre refrigerated bath circulator with a variable-speed pressure/suction pump and Pilot ONE controller, covering -40 to 200 °C with ±0.02 K stability. Its water-cooled first stage (R-452A) and 1.3–1.6 kW heater distinguish it from air-cooled siblings in the Cc series. It serves as a precise temperature source for external circuits and bath immersion applications.
Direct drop-in replacements
Peter Huber Kältemaschinenbau Cc Modelle Bis 90C Series — Model Comparison & Selection
| Model | Noise level, dB | Power supply | Pump connection | Temperature range, °C | Weight, kg | Filling volume, m³ |
|---|---|---|---|---|---|---|
| CC-415wl Kälte-Badumwälzthermostat Current | — | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | -40–200 | 61 | 0.004 |
| CC-410wl Kälte-Badumwälzthermostat | — | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | -45–200 | 71 | 0.017 |
| CC-508w Kälte-Badumwälzthermostat | 57 | 208-230V 1~/2~ 60Hz | M16x1 AG male | -55–200 | — | 0.004 |
| CC-510w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -50–200 | 106 | 0.016 |
| CC-515w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -55–200 | 105 | 0.016 |
| CC-520w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -55–200 | 161 | 0.015 |
| CC-525w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -55–200 | 163 | 0.015 |
| CC-905 Kälte-Badumwälzthermostat | 64 | 400V 3~N 50Hz | M16x1 AG male | -90–200 | 171 | 0.019 |
| CC-905w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -90–200 | 175 | 0.019 |
| CC-906w Kälte-Badumwälzthermostat | — | 460V 3~ 60Hz | M16x1 AG male | -90–200 | 234 | 0.025 |
| CC-K12 Kälte-Badthermostat | — | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -20–200 | 29 | 0.007 |
| CC-K15 Kälte-Badthermostat | — | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -20–200 | 28 | — |
| CC-K20 Kälte-Badthermostat | 50 | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -30–200 | 41 | 0.012 |
| CC-K25 Kälte-Badthermostat | 50 | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -30–200 | 41 | 0.017 |
| CC-K6 Kälte-Badumwälzthermostat | 57 | 208-240V 1~/2~ 50/60Hz | M16x1 AG male | -25–200 | 25 | — |
| Variostat Kältethermostat für variable Badgefäße | 54 | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | -30–150 | 25 | — |
Full specifications
| Bath volume | 5 l |
| Filling volume | 4 l (min) |
| Maximum delivery flow rate | 25 l/min (pressure pump, 0, 7 bar) |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | Yes |
| Pump type | Pressure and suction pump, variable speed |
| Refrigerator | air- and water-cooled, CFC-free |
| External sensor connection | Pt100 |
| Temperature range | -40...200 °C |
| Temperature stability mfr | ±0, 02 K |
| Dimensions (W x D x H) mfr | 410 x 480 x 764 mm |
| Heating capacity mfr | 1, 3 - 1, 6 kW |
| Delivery capacity suction pump max. mfr | 18, 5 l/min (suction pump, 0, 4 bar) |
| Bath opening WxD/BD mfr | 120 x 110 / 150 mm |
| Weight | 61 kg |
| Current consumption | 9 A (max) |
| Power supply | 220-240V 1~/2~ 50/60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Refrigerant | R-452A (A1, H280) (1st stage) |
| Maximum viscosity | 50 mm²/s |
| Refrigerant quantity 1st stage mfr | 0, 38 kg (1st stage) |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 66 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 3 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Cooling capacity mfr | 100:1, 2; 20:1, 2; 0:1; -20:0, 6; -30:0, 2; -40: |
| Safety class | III / FL |
Description
Construction and series positioning
- Refrigerated bath circulator with 5 l bath volume, 120 x 110 mm opening (150 mm depth), and 410 x 480 x 764 mm footprint at 61 kg.
- Water-cooled first stage using R-452A (0.38 kg, GWP 2141, 0.8 t CO2e), unlike air-cooled siblings such as the CC-508w.
- Variable-speed pressure and suction pump: 25 l/min at 0.7 bar (pressure side), 18.5 l/min at 0.4 bar (suction side); M16x1 male pump connection.
- Pilot ONE controller with Ethernet, USB host/device, RS232, and Pt100 external sensor input.
Thermal behavior
- Working range -40 to 200 °C; cooling capacity falls from 1.2 kW at 20 °C to 0.05 kW at -40 °C, so low-temperature duty requires margin.
- Heating capacity 1.3–1.6 kW; stability ±0.02 K.
- Cooling water must be 5–20 °C; higher water temperature reduces cooling power and may require increased flow.
Installation and operation
- Cooling water connection G1/2 male; minimum differential pressure 3 bar, maximum 6 bar; consumption 66 l/h at 15 °C.
- Power 220–240 V 1~/2~ 50/60 Hz, max 9 A; country-specific plug must be specified at order.
- IP20, ambient 5–40 °C; Class A Group 1 per EN55011.
- Insulate internal cooling water pipes if water temperature is below dew point.
Integration & Operating Notes
The facility cooling water supply must deliver at least 3 bar differential pressure between inlet and outlet; insufficient pressure prevents proper cooling and may cause the unit to trip. Maximum permissible pressure is 6 bar, so a regulator may be needed.
The circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM; aggressive water will corrode it. Water above 20 °C reduces cooling capacity and may require higher flow. Insulate internal pipes if water is below dew point.
Voltage tolerance is ±5% and frequency ±2%, but the combination of -5% voltage and +2% frequency is explicitly not allowed. Site power quality must be checked against this asymmetric rule to avoid damage or malfunction.
Single- and two-phase devices are supplied with a power cable and country-specific plug; the plug type must be stated when ordering, otherwise commissioning may be delayed or field wiring required.
The unit has IP20 protection and no water ingress protection; it must be installed in a dry indoor area. Ambient temperature must be 5–40 °C; higher ambient reduces cooling capacity.
The maximum permissible kinematic viscosity of the circulated fluid is 50 mm²/s; higher viscosity overloads the pump and reduces circulation performance.
The equipment is Class A, Group 1 to EN55011; it may cause interference in residential or sensitive environments, where additional EMC measures may be required.
Refrigerant R-452A charge is 0.38 kg with GWP 2141, equal to 0.8 t CO2e; this determines leak-check intervals and reporting duties under F-gas regulations. Refrigerant is A1, H280 (pressurized gas hazard).
Selection & Integration Q&A
Choose the CC-415wl when you need a 5 l bath with water-cooled condenser and -40 °C capability. Air-cooled siblings like the CC-508w avoid cooling-water plumbing but reject heat to the room; the CC-410wl offers a different bath size. Select based on bath volume, cooling-water availability, and low-temperature duty.
Cooling water: G1/2 male, 5–20 °C, 3 bar min differential, 6 bar max, 66 l/h at 15 °C. Pump: M16x1 male; pressure side 25 l/min at 0.7 bar, suction 18.5 l/min at 0.4 bar. Ensure water is compatible with copper, 1.4401, MS, PA, PPE, PTFE, EPDM.
Ambient 5–40 °C, dry indoor, IP20. Power 220–240 V 1~/2~ 50/60 Hz, max 9 A; voltage ±5%, frequency ±2%, but -5% voltage with +2% frequency is not allowed. Class A EMC may require measures in sensitive areas.
The base delivery includes power cable with country-specific plug (specify at order). Cooling-water hoses and mating fittings (G1/2, M16x1) are not included. F-gas leak checks apply (0.8 t CO2e). Insulate internal cooling-water pipes if water is below dew point.