Peter Huber Kältemaschinenbau Unistat T330 HT Dynamisches
Peter Huber Kältemaschinenbau Unistat T330 HT Dynamisches — Temperature control units.
The Unistat T330 HT Dynamisches is a high-temperature dynamic temperature control unit with a 65–300 °C working range, 24 kW heating capacity and a magnetically coupled stainless-steel pump delivering up to 96 l/min at 3.5 bar. It is the larger high-temperature dynamic modification in the Unistat T305/T330 series, distinguished by its 24 l expansion volume and 7 l minimum fill. It serves closed-loop or open-bath tempering of process equipment where rapid, controlled heat input above ambient is required.
Peter Huber Kältemaschinenbau Unistate Bis 425C Series — Model Comparison & Selection
| Model | Display resolution | Power supply | Pump connection | Pump type | Temperature range, °C | Expansion volume, m³ |
|---|---|---|---|---|---|---|
| Unistat T330 HT Dynamisches Current | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Chili Dynamisches | 0.01 | 200-240V 1~/2~ 50/60Hz | M24x1,5 AG male | Pressure pump, variable | 65–300 | 0.002 |
| Unistat T305 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305 HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T305w HT Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 65–300 | — |
| Unistat T320 Dynamisches | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T320w HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T330w HT Dynamisches | 0, 01 K | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 65–300 | 0.024 |
| Unistat T340 Dynamisches | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T340 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T345 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T350 HT Dynamisches | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 65–300 | 0.056 |
| Unistat T402 Dynamisches | 0, 01 | 400V 3~N 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | 80–425 | — |
| Unistat TR401 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 50–400 | 0.005 |
| Unistat TR402 Dynamisches | 0, 01 | 200-240V 1~/2~ 50/60Hz | M24x1, 5 (Flow) M24x1, 5 | Pressure pump, variable | 80–425 | — |
Full specifications
| Control output | POKO ONE |
| Expansion volume | 24 l |
| Filling volume | 7 l (min) |
| Heating capacity | 24 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | 65...300 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- The T330 HT Dynamisches is a 400 V three-phase, 50 Hz unit with 24 kW heating capacity, a Pilot ONE controller and POKO ONE control output, and a magnetically coupled stainless-steel pump with adjustable speed.
- Within the Unistat T305/T330 family it is the high-temperature dynamic variant with the larger fluid inventory: 24 l expansion tank and 7 l minimum filling capacity. The T305 and T305w HT siblings share the dynamic high-temperature concept but differ in size; the Chili Dynamisches is a separate cooling-focused line and should not be conflated with this unit.
- The pump port is an M30x1.5 male thread with a DIN 3863 shape Y (60°) bore, requiring ball-socket fittings to DIN 3863 and sleeve nuts to DIN 3870.
Behavior and process window
- The working range is 65 to 300 °C, so the unit is intended for high-temperature duties only; it is not a sub-ambient chiller.
- Circulation capability is up to 96 l/min at 3.5 bar maximum delivery pressure; the external circuit pressure drop must be checked against this pump curve before commissioning.
- The maximum permissible kinematic viscosity is 50 mm²/s, which constrains thermofluid selection at operating temperature.
- Safety classification III / FL to DIN 12876 with adjustable overtemperature protection allows use in flammable-liquid duties within that classification.
Installation, control and operation
- The enclosure is IP20 and must be installed indoors in a dry location; ambient temperature must remain between 5 and 40 °C.
- The unit is delivered with a cable but without a plug for three-phase supplies below 63 A; hard-wiring must be performed by an electrician and the supply must match the rating plate.
- Voltage and frequency tolerances are ±5% and ±2%, but the combination of -5% voltage with +2% frequency is not permitted.
- Leakage current exceeds 3.5 mA, so earthing and RCD selection must account for this.
- The expansion vessel must remain unlocked for externally closed applications and locked for externally open (bath) applications to prevent overpressure or fluid loss respectively.
- Interfaces include Ethernet, USB host and device, and RS232; an external Pt100 sensor can be connected.
Integration & Operating Notes
Horizontal transport damages the compressor, and moving a filled unit risks thermal fluid overflow. Casters are not for transport and carry only 25% of total mass symmetrically; use an industrial truck. Leveling feet must be activated and parking brakes engaged before commissioning.
The unit's leakage current exceeds 3.5 mA, so protective earthing and residual-current device selection must be sized for this higher leakage. Hard-wired connection must be carried out by an electrician, and supply voltage/frequency must match the rating plate.
Voltage tolerance is ±5% and frequency tolerance ±2%, but the combination of -5% voltage with +2% frequency is not allowed. Verify the site supply stays within the permitted combination before commissioning.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage. For externally open (bath) applications it must be locked to prevent fluid loss. Set the lock state before filling and commissioning.
When Process Safety mode is used to protect against exothermic reactions, the compressor must be configured to Permanently ON so that cooling remains active when the overtemperature trigger occurs. Configure this in the controller before enabling the mode.
If temperature control is active during a power outage, Power Failure Auto resumes the process automatically when power returns. Assess whether unattended restart is acceptable for the process before enabling this function.
The cooling water supply should be shut off even for short downtimes such as overnight to prevent water damage and unnecessary load on the cooling water circuit.
Hoses and hose connections must be checked periodically for leaks and material quality and replaced as required. Include this in the preventive maintenance schedule for the fluid circuit.
The unit must not be installed or started within an ATEX zone; explosion protection requires an Ex px cabinet. Site the unit outside hazardous areas and verify the area classification before installation.
When moving the unit between cold and warm environments (or vice versa), allow about 2 hours acclimation before switching on to prevent condensation-induced electrical faults.
Selection & Integration Q&A
Choose the T330 HT when the process needs the larger fluid inventory (24 l expansion, 7 l minimum fill) and 24 kW heating within the 65–300 °C range. The T305/T305w HT variants are smaller high-temperature dynamic units; select them when loop volume and heat demand are lower.
The pump port is M30x1.5 male with a DIN 3863 shape Y (60°) bore, so use ball-socket fittings to DIN 3863 and sleeve nuts to DIN 3870. Confirm the loop pressure drop fits the 96 l/min at 3.5 bar pump capability and keep fluid viscosity below 50 mm²/s.
Install indoors, IP20, ambient 5–40 °C, outside any ATEX zone, upright and level with brakes/feet set. Supply is 400 V 3~ 50 Hz with ±5% voltage and ±2% frequency, but not -5% voltage with +2% frequency. Leakage current exceeds 3.5 mA.
The unit ships with a cable but no plug for three-phase supplies below 63 A, so the site must provide and fit the plug. Plan periodic hose and connection inspection and replacement, and shut off cooling water during downtimes. No accessories or consumables beyond the cable are included.