Peter Huber Kältemaschinenbau CC-K20 Kälte-Badthermostat
Peter Huber Kältemaschinenbau CC-K20 Kälte-Badthermostat — Thermostatic baths with Noise level 50 dB.
The CC-K20 is a 17-litre refrigerated/heating bath circulator with a variable-speed pressure/suction pump, covering -30 to 200 °C with ±0.02 K stability. Its air-cooled R-290 first stage and Pilot ONE controller distinguish it from larger CC-405w/410wl/415wl/505wl siblings. It serves as a precise temperature source for external circuits or direct bath immersion in laboratory processes.
Direct drop-in replacements
Peter Huber Kältemaschinenbau Cc Modelle Bis 90C Series — Model Comparison & Selection
| Model | Noise level, dB | Power supply | Pump connection | Temperature range, °C | Weight, kg | Filling volume, m³ |
|---|---|---|---|---|---|---|
| CC-K20 Kälte-Badthermostat Current | 50 | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -30–200 | 41 | 0.012 |
| CC-410wl Kälte-Badumwälzthermostat | — | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | -45–200 | 71 | 0.017 |
| CC-415wl Kälte-Badumwälzthermostat | — | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | -40–200 | 61 | 0.004 |
| CC-508w Kälte-Badumwälzthermostat | 57 | 208-230V 1~/2~ 60Hz | M16x1 AG male | -55–200 | — | 0.004 |
| CC-510w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -50–200 | 106 | 0.016 |
| CC-515w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -55–200 | 105 | 0.016 |
| CC-520w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -55–200 | 161 | 0.015 |
| CC-525w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -55–200 | 163 | 0.015 |
| CC-905 Kälte-Badumwälzthermostat | 64 | 400V 3~N 50Hz | M16x1 AG male | -90–200 | 171 | 0.019 |
| CC-905w Kälte-Badumwälzthermostat | — | 400V 3~N 50Hz | M16x1 AG male | -90–200 | 175 | 0.019 |
| CC-906w Kälte-Badumwälzthermostat | — | 460V 3~ 60Hz | M16x1 AG male | -90–200 | 234 | 0.025 |
| CC-K12 Kälte-Badthermostat | — | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -20–200 | 29 | 0.007 |
| CC-K15 Kälte-Badthermostat | — | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -20–200 | 28 | — |
| CC-K25 Kälte-Badthermostat | 50 | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -30–200 | 41 | 0.017 |
| CC-K6 Kälte-Badumwälzthermostat | 57 | 208-240V 1~/2~ 50/60Hz | M16x1 AG male | -25–200 | 25 | — |
| Variostat Kältethermostat für variable Badgefäße | 54 | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | -30–150 | 25 | — |
Full specifications
| Noise level | 50 dB(A) |
| Bath volume | 17 l |
| Dimensions (w × D × H) | 350 x 555 x 615 mm |
| Filling volume | 12 l (min.) |
| Maximum delivery flow rate | 27 l/min (pressure pump max.; 0, 7 bar) suction pump max.; 0, 4 bar: 22 l/min |
| Pump connection | (Option, #19607) (Option) |
| Pump speed adjustable | Yes |
| Pump type | Pressure and suction pump, variable speed |
| Refrigerator | air-cooled, natural refrigerant |
| External sensor connection | Pt100 |
| Temperature range | -30...200 °C |
| Temperature stability mfr | ±0, 02 K |
| Heating capacity mfr | 1, 8 - 2, 1 kW |
| Bath opening WxD/BD mfr | 290 x 329 / 150 (WxD/BD) |
| Weight | 41 kg (net) |
| Power supply | 220-240V 1~/2~ 50/60Hz |
| Current consumption max. mfr | 10 + 2 A (max.) |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Refrigerant | R-290 (A3, H220) (1st stage) |
| Refrigerant quantity 1st stage mfr | 0, 072 kg (1st stage) |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Cooling capacity mfr | 20:0, 4; 0:0, 35; -10:0, 27; -20:0, 16; -30:0, 0 |
| Safety class | III / FL |
Description
Construction and series positioning
- Bath volume 17 l, working opening 290 x 329 mm, depth 150 mm; minimum filling volume 12 l.
- Air-cooled refrigeration circuit using R-290 (A3, H220), 0.072 kg first-stage charge; heating capacity 1.8–2.1 kW.
- Safety class III / FL per DIN 12876; enclosure IP20; EMC class A, group 1 (EN55011) for industrial environments.
- Compared with the CC-405w/410wl/415wl/505wl siblings, this is the compact 17-litre modification; the larger models are intended where greater bath volume or immersion area is required.
Thermal behaviour under load
- Temperature range -30…200 °C; stability ±0.02 K.
- Cooling capacity falls with set point: 0.4 kW at 20 °C, 0.35 kW at 0 °C, 0.27 kW at -10 °C, 0.16 kW at -20 °C, 0.065 kW at -30 °C. The low-temperature working point must be checked against the actual heat load.
- Pump delivers up to 27 l/min at 0.7 bar pressure and 22 l/min at 0.4 bar suction; speed is adjustable.
Installation, control and operation
- Power supply 220–240 V, 1~/2~, 50/60 Hz; maximum current 10 + 2 A; voltage tolerance ±5 %, frequency ±2 %, with the combination -5 % voltage and +2 % frequency not allowed.
- Pilot ONE controller; interfaces Ethernet, USB host and device, RS232; external Pt100 sensor connection.
- Air-cooled condenser requires unobstructed airflow and cool intake air; ambient temperature 5–40 °C, with cooling capacity falling as ambient rises.
- IP20 enclosure must be kept away from water spray and conductive dust.
- When a Huber pump adapter is used, polyglycol must not be used as heat transfer fluid.
- Single- and two-phase units are delivered with power cable and country-specific plug, to be specified at ordering.
Integration & Operating Notes
The refrigeration stage must be sized against the actual heat load at the coldest set point; at -30 °C the available cooling capacity is 0.065 kW, so excessive load or poor insulation will prevent the bath from reaching or holding the set point.
The supply must remain within ±5 % voltage and ±2 % frequency, but the combination of -5 % voltage and +2 % frequency is explicitly not allowed; verify grid quality at the site before connection to avoid compressor and electronics damage.
The unit is air-cooled, so sufficient clearance and cool intake air must be provided at the installation location; ambient temperature must stay between 5 °C and 40 °C, and cooling capacity may drop as ambient temperature rises.
When a Huber pump adapter is used, polyglycol must not be used as the heat transfer fluid; selecting the wrong fluid can damage the pump and seals.
Single- and two-phase devices are delivered with a power cable and country-specific plug; the plug type must be stated on the order to avoid a non-matching mains connection on site.
A drain valve with cap (#6839) is available as an accessory; planning its installation at commissioning avoids awkward fluid handling during later bath draining and fluid changes.
Selection & Integration Q&A
Choose the CC-K20 when a 17-litre bath with 290 x 329 mm opening and -30…200 °C range covers your sample size and heat load. The larger siblings are for greater bath volume or immersion area; verify cooling capacity at your coldest set point first.
The variable-speed pressure/suction pump delivers up to 27 l/min at 0.7 bar pressure and 22 l/min at 0.4 bar suction. With a Huber pump adapter, polyglycol must not be used as heat transfer fluid.
Ambient 5–40 °C, IP20 enclosure away from water spray and conductive dust, air-cooled condenser with unobstructed airflow. Supply 220–240 V 1~/2~ 50/60 Hz within ±5 %/±2 %, but not -5 % voltage with +2 % frequency.
The drain valve with cap (#6839) and the pump connection (#19607) are options/accessories. The power cable and country-specific plug are included but the plug type must be specified at ordering.