Elmo Rietschle 2BH7620
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH7620

Elmo Rietschle 2BH7620 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -530 mbar, Motor power 8.8 kW, Noise level 79 dB.

The 2BH7620 is a side-channel blower from the G-BH7 e series with an integrated frequency converter, rated 10.2 kW at 50 Hz and 12.1 kW at 60 Hz. It delivers up to ±570 mbar differential pressure at 50 Hz and ±530 mbar at 60 Hz, distinguishing it from smaller siblings in the series. It is used for vacuum or pressure duty in industrial processes requiring compact, variable-speed blower packages.

Max. differential pressure
-530 mbar
Motor power
8.8 kW
Noise level
79 dB
Weight
77 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH7620 Current 8.879-5307716.2400
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -530 mbar
Motor power 8.8 kW
Noise level 79 dB(A)
Max. differential pressure vacuum mfr -570 mbar (50 Hz)
VFD type mfr 2BH7620-0A341-2
Motor connection mfr delta
Performance basis atmospheric pressure mfr 1013 mbar
Performance curve tolerance mfr ± 10 %
Max. differential pressure (alt var) mfr 390 mbar
Dimensions, Weight & Mechanical Design
Weight 77 kg
Weight approx. mfr 75 kg
Electrical, Power & Drive Specifications
Current 16.2 A
Frequency 100 Hz
Power supply 3~ 50/60 Hz, IP55, Insulation material class F, UL 1004 and CNA/CSA 22.2 No 68-09
Voltage 400 V
Rated motor voltage mfr 380 V (50 Hz)
Rated motor current mfr 20.3 A (50 Hz)
Rated motor power mfr 10.2 kW (50 Hz)
Rated motor voltage mfr 400 V (60 Hz)
Rated motor current mfr 22.0 A (60 Hz)
Rated motor power mfr 12.1 kW (60 Hz)
Frequency converter rated mains voltage mfr 400V (-15%) ... 480V (+10%) V
Frequency converter mains frequency mfr 50/60 Hz (±6%)
Rated motor voltage mfr 400 V
Rated motor current mfr 16.2 A
Operating voltage/frequency set point mfr 345 V / 87 Hz
Frequency converter min. mains voltage mfr 380 V
Frequency converter pulse frequency minimum mfr 4 kHz
Integrated VFD mains voltage mfr 400V -15% ... 480V +10% V
Integrated VFD frequency mfr 50/60 Hz (±6%)
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 °C
Sound pressure level mfr 75 dB(A) (50 Hz)
Sound pressure level mfr 79 dB(A) (60 Hz)
Sound pressure level with G17 mfr 75/76 dB(A) (50/60 Hz)
Sound pressure level mfr 77 dB(A)
Sound pressure level with G17 mfr 75 dB(A)

Description

Construction and series positioning

Performance and load behavior

Installation and operation

Integration & Operating Notes

Electrical
Converter mains voltage tolerance is -15% to +10%

The integrated frequency converter is rated for 400 V (-15%) to 480 V (+10%) at 50/60 Hz (±6%). Exceeding these limits risks converter damage and invalidates warranty. Verify supply voltage and frequency stability before commissioning.

Technical Data Sheet — G-BH7 2BH7620 side channel blower
Process Limits
Maximum differential pressure is 570 mbar at 50 Hz

Operating above 570 mbar differential pressure (vacuum or pressure) at 50 Hz may cause overheating and motor overload. At 60 Hz, the limit is 530 mbar. Use pressure relief or bypass if process can exceed these values.

Technical Data Sheet — G-BH7 2BH7620 side channel blower
Mounting
Mount on rigid, level surface with sufficient clearance

The blower weighs approximately 75 kg. Install on a flat, vibration-resistant base. Ensure unobstructed air intake and exhaust, and allow space for maintenance access and cooling air flow around the motor and converter.

Technical Data Sheet — G-BH7 2BH7620 side channel blower
Maintenance
Regularly inspect and clean air filters and cooling passages

Dust accumulation on the motor and converter cooling fins can cause overheating. Check and clean periodically according to the instruction manual. Replace worn seals and bearings as recommended by the manufacturer.

Technical Data Sheet — G-BH7 2BH7620 side channel blower

Selection & Integration Q&A

When should I choose the 2BH7620 over the smaller 2BH7210 or 2BH7220 models?

Choose the 2BH7620 when you need higher differential pressure (up to ±570 mbar at 50 Hz) and motor power (10.2 kW). The 2BH7210 and 2BH7220 offer lower pressure and power, suitable for smaller flows or lower pressure ratios. Select based on required flow and pressure at operating speed.

What are the requirements for the mains supply and protection devices for the integrated frequency converter?

The converter requires a 3-phase supply of 400 V (-15%) to 480 V (+10%) at 50/60 Hz (±6%). Use fuses or circuit breakers rated for the converter input current (consult manual). Ensure proper earthing and shielded motor cables to meet EMC requirements.

What are the ambient temperature and duty cycle limits for continuous operation?

The data sheet does not specify ambient temperature limits; refer to the instruction manual. Typically, side channel blowers are rated for continuous duty (S1) at ambient up to 40°C. Ensure adequate cooling and avoid exceeding maximum differential pressure to prevent overheating.

What maintenance items and accessories are not included in the base delivery?

The base delivery includes the blower with integrated converter. Silencers (e.g., G17), filters, and connection flanges are optional accessories. Spare parts such as bearings, seals, and filter elements must be ordered separately. Regular maintenance includes cleaning filters and checking electrical connections.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH7 2BH7620 side channel blower (EN)
Datasheet ·266,0 КБ ·2 pp.
View PDF